Mô tả sản phẩm: Fluke 117/322 Multimeter
Fluke 117 True-RMS digital multimeter with non-contact voltage detection
Fluke 332 Compact clamp meter
TPAK Magnetic Meter Hanging Strap
TL75 Hard Point test lead set
C115 Deluxe soft carrying case with shoulder strap
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Surge protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 | |
Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
Display | Digital: | 6,000 counts, updates 4 per second |
Bar graph | 33 segments, updates 32 per second | |
Operating Temperature | -10 °C to + 50 °C | |
Storage Temperature | -40 °C to + 60 °C | |
Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
Battery Life | 400 hours typical, without backlight | |
Accuracy Specifications | ||
DC millivolts | Range: | 600.0 mV |
Resolution: | 0.1 mV | |
Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/Resolution: | 6.000 V / 0.001 V |
Range/Resolution: | 60.00 V / 0.01 V | |
Range/Resolution: | 600.00 V / 0.1 V | |
Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range: | 600.0 V |
Resolution: | 0.1 V | |
Accuracy: | 2.0 % + 3 (dc, 45 Hz to 500 Hz) | |
4.0 % + 3 (500 Hz to 1 kHz) | ||
AC millivolts1 true-rms | Range: | 600.0 mV |
Resolution: | 0.1 mV | |
Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz) | |
2.0 % + 3 (500 Hz to 1 kHz) | ||
AC volts1 true-rms | Range/Resolution: | 6.000 V / 0.001 V |
Range/Resolution: | 60.00 V / 0.01 V | |
Range/Resolution: | 600.0 V / 0.1 V | |
Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz) | |
2.0 % + 3 (500 Hz to 1 kHz) | ||
Continuity | Range: | 600 Ω |
Resolution: | 1 Ω | |
Accuracy: | Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. | |
Ohms | Range/Resolution: | 600.0 Ω / 0.1 Ω |
Range/Resolution: | 6.000 kΩ / 0.001 kΩ | |
Range/Resolution: | 60.00 kΩ / 0.01 kΩ | |
Range/Resolution: | 600.0 kΩ / 0.1 kΩ | |
Range/Resolution: | 6.000 MΩ / 0.001 MΩ | |
Accuracy: | 0.9 % + 1 | |
Range/Resolution: | 40.00 MΩ / 0.01 MΩ | |
Accuracy: | 5 % + 2 | |
Diode Test | Range/Resolution: | 2.000 V / 0.001 V |
Accuracy: | 0.9% + 2 | |
Capacitance | Range/Resolution: | 1000 nF / 1 nF |
Range/Resolution: | 10.00 μF / 0.01 μF | |
Range/Resolution: | 100.0 μF / 0.1 μF | |
Range/Resolution: | 9999 μF / 1 μF | |
Range/Resolution: | 100 μF to 1000 μF | |
Accuracy: | 1.9% + 2 | |
Range/Resolution: | > 1000 μF | |
Accuracy: | 5% + 20% | |
LoZ capacitance | Range: | 1 nF to 500 μF |
Accuracy: | 10% + 2 typical | |
AC amps true-rms (45 Hz to 500 Hz) | Range/Resolution: | 6.000 A / 0.001 A |
Range/Resolution: | 10.00 A / 0.01 A | |
Accuracy: | 1.5% + 3 | |
20 A continuous overload for 30 seconds max | ||
DC amps | Range/Resolution: | 6.000 A / 0.001 A |
Range/Resolution: | 10.00 A / 0.01 A | |
Accuracy: | 1.0% + 3 | |
20 A continuous overload for 30 seconds max | ||
Hz (V or A input)2 | Range/Resolution: | 99.99 Hz / 0.01 Hz |
Range/Resolution: | 999.99 Hz / 0.1 Hz | |
Range/Resolution: | 9.999 Hz / 0.001 Hz | |
Range/Resolution: | 50.00 Hz / 0.01 Hz | |
Accuracy: | 0.1% + 2 |