Mô tả sản phẩm: Đồng hồ đo vạn năng KYORITSU K6202
RPE 20Ω+ / 20Ω- Protective Conductor Resistance Test | |||||||||||
Measuring range | 0 ~ 19.99Ω | ||||||||||
Resolution of measurement | 10mΩ | ||||||||||
Short circuit current | 200 ~ 250mA DC | ||||||||||
Open circuit voltage | ±5.0±0.4V DC | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
RINS 200MΩ Insulation Resistance | |||||||||||
Measuring range | 0 ~ 19.99 / 199.9MΩ (2ranges auto) | ||||||||||
Resolution of measurement | 10kΩ / 100kΩV | ||||||||||
Rated voltage | >500V DC (+50% / -0%) | ||||||||||
Rated current | >1mA | ||||||||||
Short circuit current | 14mA (max.) | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
IEL 20mA Equivalent Leakage Current | |||||||||||
Measuring range | 0 ~ 19.99mA | ||||||||||
Resolution of measurement | 0.01mA | ||||||||||
Measuring voltage | 30V AC | ||||||||||
Internal resistance (RA Meter) | 2kΩ | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
IL 2mA Contact Current | |||||||||||
Measuring range | 0 ~ 1.999mA | ||||||||||
Resolution of measurement | 0.001mA | ||||||||||
Internal resistance (RA Meter) | 2kΩ | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
VOLT AC Voltmeter | |||||||||||
Measuring range | 180 ~ 260V (50/60Hz) | ||||||||||
Resolution of measurement | 1V | ||||||||||
Accuracy | ±3%rdg±5dgt | ||||||||||
I LINE Current Consumption (6202 only) | |||||||||||
Measuring range | 0 ~ 16A AC | ||||||||||
Resolution of measurement | 0.01A | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
Supply voltage | 230V±10% | ||||||||||
Frequency | 50/60Hz±1% | ||||||||||
Applicable standards | IEC 61010-1 CAT.III 300V Pollution Degree2 IEC 60950, IEC 61326-1 (EMC) |
||||||||||
Dimensions | 185 (L) × 167 (W) × 89 (D) mm | ||||||||||
Weight | 1kg | ||||||||||
Accessories | 7125 (Power cord [EU]) 7129A (Test leads with alligator clip) 7161A (Flat test prod [black]) 9147 (Cord case) 9121 (Shoulder strap) Instruction manual |
||||||||||
Optional | 7121B (Distribution board test leads) |
RPE 20Ω+ / 20Ω- Protective Conductor Resistance Test | |||||||||||
Measuring range | 0 ~ 19.99Ω | ||||||||||
Resolution of measurement | 10mΩ | ||||||||||
Short circuit current | 200 ~ 250mA DC | ||||||||||
Open circuit voltage | ±5.0±0.4V DC | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
RINS 200MΩ Insulation Resistance | |||||||||||
Measuring range | 0 ~ 19.99 / 199.9MΩ (2ranges auto) | ||||||||||
Resolution of measurement | 10kΩ / 100kΩV | ||||||||||
Rated voltage | >500V DC (+50% / -0%) | ||||||||||
Rated current | >1mA | ||||||||||
Short circuit current | 14mA (max.) | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
IEL 20mA Equivalent Leakage Current | |||||||||||
Measuring range | 0 ~ 19.99mA | ||||||||||
Resolution of measurement | 0.01mA | ||||||||||
Measuring voltage | 30V AC | ||||||||||
Internal resistance (RA Meter) | 2kΩ | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
IL 2mA Contact Current | |||||||||||
Measuring range | 0 ~ 1.999mA | ||||||||||
Resolution of measurement | 0.001mA | ||||||||||
Internal resistance (RA Meter) | 2kΩ | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
VOLT AC Voltmeter | |||||||||||
Measuring range | 180 ~ 260V (50/60Hz) | ||||||||||
Resolution of measurement | 1V | ||||||||||
Accuracy | ±3%rdg±5dgt | ||||||||||
I LINE Current Consumption (6202 only) | |||||||||||
Measuring range | 0 ~ 16A AC | ||||||||||
Resolution of measurement | 0.01A | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
Supply voltage | 230V±10% | ||||||||||
Frequency | 50/60Hz±1% | ||||||||||
Applicable standards | IEC 61010-1 CAT.III 300V Pollution Degree2 IEC 60950, IEC 61326-1 (EMC) |
||||||||||
Dimensions | 185 (L) × 167 (W) × 89 (D) mm | ||||||||||
Weight | 1kg | ||||||||||
Accessories | 7125 (Power cord [EU]) 7129A (Test leads with alligator clip) 7161A (Flat test prod [black]) 9147 (Cord case) 9121 (Shoulder strap) Instruction manual |
||||||||||
Optional | 7121B (Distribution board test leads) |
RPE 20Ω+ / 20Ω- Protective Conductor Resistance Test | |||||||||||
Measuring range | 0 ~ 19.99Ω | ||||||||||
Resolution of measurement | 10mΩ | ||||||||||
Short circuit current | 200 ~ 250mA DC | ||||||||||
Open circuit voltage | ±5.0±0.4V DC | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
RINS 200MΩ Insulation Resistance | |||||||||||
Measuring range | 0 ~ 19.99 / 199.9MΩ (2ranges auto) | ||||||||||
Resolution of measurement | 10kΩ / 100kΩV | ||||||||||
Rated voltage | >500V DC (+50% / -0%) | ||||||||||
Rated current | >1mA | ||||||||||
Short circuit current | 14mA (max.) | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
IEL 20mA Equivalent Leakage Current | |||||||||||
Measuring range | 0 ~ 19.99mA | ||||||||||
Resolution of measurement | 0.01mA | ||||||||||
Measuring voltage | 30V AC | ||||||||||
Internal resistance (RA Meter) | 2kΩ | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
IL 2mA Contact Current | |||||||||||
Measuring range | 0 ~ 1.999mA | ||||||||||
Resolution of measurement | 0.001mA | ||||||||||
Internal resistance (RA Meter) | 2kΩ | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
VOLT AC Voltmeter | |||||||||||
Measuring range | 180 ~ 260V (50/60Hz) | ||||||||||
Resolution of measurement | 1V | ||||||||||
Accuracy | ±3%rdg±5dgt | ||||||||||
I LINE Current Consumption (6202 only) | |||||||||||
Measuring range | 0 ~ 16A AC | ||||||||||
Resolution of measurement | 0.01A | ||||||||||
Accuracy | ±2%rdg±3dgt | ||||||||||
Supply voltage | 230V±10% | ||||||||||
Frequency | 50/60Hz±1% | ||||||||||
Applicable standards | IEC 61010-1 CAT.III 300V Pollution Degree2 IEC 60950, IEC 61326-1 (EMC) |
||||||||||
Dimensions | 185 (L) × 167 (W) × 89 (D) mm | ||||||||||
Weight | 1kg | ||||||||||
Accessories | 7125 (Power cord [EU]) 7129A (Test leads with alligator clip) 7161A (Flat test prod [black]) 9147 (Cord case) 9121 (Shoulder strap) Instruction manual |
||||||||||
Optional | 7121B (Distribution board test leads) |