Mô tả sản phẩm: Professional Combustion Flue Gas Analyser (up to 3 sensors) EURTRON UniGas 2000+
Description:
Two internal electrochemical sensors read the Oxygen (O2) and carbonic monoxide (CO) gas concentration.
The gas temperature and air temperature are used in connection with the gas analysis to calculate the efficiency, excess air, and CO2 concentration.A 10 gas parameters programmable table is used for calculations approved in accordance with DIN33962.
External sensors are available for auxiliary measurements: ambient CO concentration (for operator’s safety), gas network leakage procedure (pressure decay method) and natural gas leakage detector (sniffer).
The instrument is completed with a differential pressure (draught) sensor, an internal printer, an internal memory for storing data and a USB serial interface for configuration and data transfer from and to a PC. Draft measurement is possible using the internal pressure sensor and the Eurotron special gas sample probe.
- The optional internal printer is impact type and the generated document is very legible and has a long time duration.
- The internal standard memory may store up to 250 complete gas analysis divided by Tag.
- The UniGas has a standard IR serial interface for external HP 82240B thermal wireless printer.
- The optional USB cable and a configuration PC software are available to configure the analyser.
- Type: palm-top combustion gas analyser
- Calibration: automatic calibration procedure at instrument switch-On.
- Self-diagnosis: Sensors efficiency test with display diagnostic messages.
- Fuel types: Up to 10 selectable from keyboard (most common preprogrammed).
- Power supply: High capacity Li-ion rechargeable battery pack / external battery charger.
- Charging time: 8h at 90% with instrument off
- Battery life: 6 hours (typical) continuous use (without printing and backlight).
- Printer: Internal impact type 24 columns with paper roll. (10m)
- Printer power supply: from the analyser battery pack.
- Print autonomy: up to 40 reports with full battery (typical).
- Printed report header: 4 programmable lines.
- Display: 40x58 mm alpha-numeric LCD with backlight device.
- Serial communication: RS232 interface. USB cable optional.
- Infrared port: compatible with HP82240B cordless printer.
- Operating temperature: from -5°C to +45°C - from -10 to 90% RH
- Storage temperature: from -20 to +50°C (3 months maximum at temperatures exceeding the operational limits).
- Dimensions and Weight: 115x90x330 mm - 1.1 kg with battery and printer
- Warranty: 2 years sensors, connectors, battery, printer & pump included
- Base unit with 2 sensors (O2 + CO-H2 compensated)
- Li-ION battery + charger module
- Built-in impact printer
- IR port for thermal printer
- Differential pressure sensor
- Rubber holster magnetic
- PC software GasConfig + DBGas2004 Lite + USB cable (EE700476)
- Instruction manual
- Calibration certificate
- Warranty 2 year
- A - Sensor N°1
- 1 - O2 (0-25%)
- B - Sensor N°2 & N°3
- 2H - Sensor N°2 : CO(0-8000ppm) - H2 compensated
- 4 - Sensor N°3 : CO(0-4000ppm) - NOx calculated
- C - Sampling Probe (including water trap and line filter)
- 0 - None
- 1 - 180mm sampling single hose probe BB610047 (Gas or Draft)
- 2 - 300mm sampling single hose probe BB610048 (Gas or Draft)
- D - Options
- 1 - Pressure decay program firmware + Gas network leak test kit
- 2 - Internal sensor for gas leak detector (sniffer)
- 3 - External probe for gas leak detector (sniffer)
- 4 - External CO ambient probe for monitoring
- 6 - DBGas 2004 STANDARD software
- 8 - Pt100 remote air temperature sensor (2m cable) and positioning cone
- 9 - Differential pressure connection kit (2 x EE300088)
- P - Built-in impact printer
- E - Mains adapter / charger
- 1 - 115V ±10% 50/60Hz - USA plug
- 2 - 230V ±10% 50/60Hz - Schuko plug
- 3 - 230V ±10% 50/60Hz - UK plug
- 4 - 230V ±10% 50/60Hz - Europe plug
- 5 - 100V ±10% 50/60Hz - USA/Japan plug
- F - Accessories (up to 3 elective)
- 0 - None
- 1 - Magnetic support
- 2 - Rubber holster with magentic support
- 3 - Vinyl carrying case with shoulder strap
- 4 - ABS rigid carrying case
- 6 - Manual pump for smoke index measurments + 40 filters + table
- G - Calibration certificate
- 1 - Factory certificate (gas, pressure & temperature)
- X - Instruction manual
- ENG - English
Order accessories below.
- BB880028 - ABS carrying case
- BB880043 - Compact rigid carrying case with shoulder strap. Greenline 2000, probes and accessories need 1/3 of the classic carrying case space
- EE880047 - Rubber holster with magnetic support
- BB610051 - 180mm sampling dual hose probe BB610051 (Gas + Draft) max 800°C
- BB610046 - 300mm sampling dual hose probe BB610046 (Gas + Draft) max 800°C
- BB830009 - Ambient CO probe
- BB830010 - Gas sniffer probe
- F2132100 - 130mm air K-Type Thermocouple
- F2137100 - 130mm contact K-Type Thermocouple
- F2139000 - Pipe Velcro TC K-type probe
- F2139100 - Tc K-type clamp temperature probe
- F2139200 - Pt100 clamp temperature probe
- BB610057 - 3m extention for dual hose sample probe + Tc
- BB610103 - 6m extention for dual hose sample probe + Tc
- EE300088 - Single hose pressure probe and burner hose kit
- F7828000 - Manual pump for smoke index measurments + 40 filters + table
- BB260166 - DBGas 2004 STANDARD software
- EE700476 - USB adaptator cable