RPE 20Ω Protective Conductor Resistance Test | ![]() |
|||||||||
![]() |
![]() |
![]() |
Measuring range | ![]() |
0 ~ 15.00Ω | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Resolution of measurement | ![]() |
10mΩ | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Open circuit voltage | ![]() |
< AC 12V | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
||||||||||
![]() |
![]() |
![]() |
Measuring current | ![]() |
10A AC nominal value | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Accuracy | ![]() |
±3%rdg±5dgt | ![]() |
|||||
![]() |
RINS 200MΩ Insulation Resistance | ![]() |
|||||||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||||
![]() |
![]() |
![]() |
Rating | ![]() |
250V/20MΩ | ![]() |
![]() |
![]() |
500V/20MΩ | ![]() |
|
![]() |
![]() |
||||||||||
![]() |
![]() |
![]() |
Measuring range | ![]() |
0 ~ 19.99Ω | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Resolution of measurement | ![]() |
10kΩ | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||||
![]() |
![]() |
![]() |
Output voltage | ![]() |
250V DC (+20%/-10%) @1MΩ | ![]() |
![]() |
![]() |
500V DC (+20%/-10%) @1MΩ | ![]() |
|
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Short circuit current | ![]() |
2.5mA DC or less | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Accuracy | ![]() |
±2%rdg±3dgt | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
|||||||||||
![]() |
Leakage Current Test | ![]() |
|||||||||
![]() |
|||||||||||
![]() |
![]() |
![]() |
Measuring range | ![]() |
AC 0.1 ~ 19.99mA | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Resolution of measurement | ![]() |
0.01mA | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Examination time | ![]() |
Max 15 seconds | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Accuracy | ![]() |
±3%rdg±5dgt | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
AC VOLT Mains Voltage Check | ![]() |
|||||||||
![]() |
|||||||||||
![]() |
![]() |
![]() |
Measuring range | ![]() |
207 ~ 264V | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Resolution of measurement | ![]() |
1V | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
![]() |
![]() |
Accuracy | ![]() |
±2%rdg±3dgt | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
||||||||
![]() |
Supply voltage | ![]() |
240V±10% | ![]() |
|||||||
![]() |
![]() |
||||||||||
![]() |
Frequency | ![]() |
50Hz±1% | ![]() |
|||||||
![]() |
![]() |
||||||||||
![]() |
Applicable standards | ![]() |
IEC 61010-1 CAT.III 300V Pollution Degree2 IEC 61326-1 (EMC) |
![]() |
|||||||
![]() |
![]() |
||||||||||
![]() |
Dimensions | ![]() |
185 (L) × 167 (W) × 89 (D) mm | ![]() |
|||||||
![]() |
![]() |
||||||||||
![]() |
Weight | ![]() |
1.2kg (only the instrument body) | ![]() |
|||||||
![]() |
![]() |
||||||||||
![]() |
Accessories | ![]() |
7123 (Power cord [AU]) 7129A (Test leads with alligator clip) 7161A (Flat test prod [black]) 7140 (Adapter for exntesion cord) 9147 (Cord case) 9121 (Shoulder strap) Instruction manual |
![]() |
|||||||
![]() |
![]() |
||||||||||
![]() |
Optional | ![]() |
7121B (Distribution board test leads) |