Mô tả sản phẩm: Máy phát điện SINGFO SFJ1375
CE approved water-cooled cummins diesel genset generates your cummins diesel genset need
Technical parameters of cummins diesel GenSet:
Power factor |
COSΦ=0.8lagging |
Phase/wires |
3 phase 4 wires |
Start mode |
Electric |
Fuel consumption: |
261L/h(at 100% Prime load) |
Rated currency(amps) |
1250 |
Protection |
Low oil-pressure, High water temperature, Over-speed, Over-current. |
Technical parameters of cummins diesel genset Engine:
Brand |
Cummins |
||
Model |
KTA50-G3 |
Standby Power |
1227kw/1534KVA |
Original: |
Sino-U.S joint venture in China |
Start mode |
DC24V electric start |
Cylinders |
16 |
Cylinders Layout |
Line |
Fuel |
0# light diesel |
Displacement |
50.3L |
Inter-Cooling |
water inter-cooling |
Speed-Governing |
Electric |
Overload |
110% |
Steady Speed Droop |
≤1% |
Technical parameters of cummins diesel genset Alternator:
Brand |
Stamford |
||
Model |
LVI-634G |
Power |
1000kw(1200kva) |
Original |
China & England joint venture in China |
Rated voltage |
440/254v |
Protection |
IP23 |
Insulation |
H |
Frequency fluctuation |
≤±0.5 % |
Frequency regulation |
≤±0.5 %stable |
Voltage distortion |
4% |
Voltage control |
AVR |
Technical parameters of cummins diesel genset Control Panel:
Brand: Smartgen Model: 6310
Function:
·Start or Stop Generator set manually/ Automatically
·Open controller output can be defined as Pre-heat/Idle output
·High Coolant temperature protection
·Low Oil pressure protection
·Over load protection
·Generator over/under frequency protection
·Generator over/under/unbalance voltage Protection
·Over speed protection
·Over speed protection
·Available for remote control
NoteIndicate this function depend on the set points of the controller in field.
*Standard cummins diesel genset Accessories*
1. Accessories.
Single-bearing generator again drops. IP23. Insulation H
Radiator for 50 ambient temperature and double-deck cooling
Intelligent control panel with Regulator.
Electric start and 24v charger
Standard air filter, oil filter, fuel filter.
Cooling water tank
Daily base fuel tank. 250 liters(only for silent type).
High-efficient silencer.
Exhaust elbow
Storage battery
Switch for out-wire
Steel base-frame against vibration
Soft pipe for fuel and handle for lube going-out
Operation& Maintenance manual.
2. Testing conditions.
Standard Air Intake Temperature 25ºC
Air Intake Pressure 100kpa
Standard Light Diesel 0# or 10# Light diesel
Fuel Intake Temperature 40ºC
Air Intake Restriction 254mmHg
Exhaust Back Pressure 76mmHg
Lubricant Oil 15W40-CF4 Upgrade
3. Operation.
Continuous power: operate continuously for 24h in a day. 10% overload for
An hour is allowed in a 12 hours.
Standby power: this is used only when the civil power is off. Overload is not allowed.
We Also Have Full Range of Optional Accessories of Cummins Diesel Genset
1. ATS (Automatic Transfer switch); Which can start the diesel generator when the main power is off; If the main power comes back, it will shut down generator. And ATS have the function of AMF (Automatic Main power failure).
2. MCCB (Molded case circuit breaker);
3. Battery charger (float charger);
4. Extra daily fuel tank;
5. Paralleling system;
This system can make several generators work together and automatically distribute the load according to set.
6. Remote Control Panel;
7. Water separate (additional cooling system);
8. Spare Parts of Cummins engine;