Mô tả sản phẩm: Rrefabricated Building B Type House
Product profile :
No. |
classification |
Name |
Specification & Parameter |
1 |
Type |
standardization |
custom made products, design and manufacture according to client's demand |
2 |
disassembly and assembly |
not suitable for assemble and disassemble, lower repeating utilization factor. |
|
3 |
Specification |
Length: |
No limited, increase expansion joint when length more than 200m. |
4 |
Width: |
≤11m |
|
5 |
Height: |
≤3.0m |
|
6 |
Roof slope: |
double slope,1:6-1:4 |
|
7 |
Floors: |
1 floor |
|
8 |
Standard |
Ground channel |
Galvanized steel panel pressure, steel panel thickness is 0.8mm |
9 |
Post |
Outdoor post is square steel pipe, material is Q235,components make bottom and surface painted process. |
|
10 |
roof beam |
Triangle roof frame is welded by square steel pipe,components surface is made rust-proof process. |
|
11 |
Purlin |
Purlin is square steel pipe,material is Q235,components surface is made rust-proof process. |
|
12 |
wallboard |
75mm~150mm thickness color steel sandwich panel, white color |
|
13 |
roof board |
75~150mm thickness color steel sandwich panel, white color |
|
14 |
roof tiles |
V35-125-350 color steel tiles,blue or red color |
|
15 |
door |
sandwich panel door,size:750mm*2000mm; |
|
16 |
window |
PVC sliding window, conch model |
|
17 |
Options |
ceiling |
roof board is also ceiling board, so this house don't need to make ceiling again. |
18 |
canopy |
color steel sheet or color steel sandwich panel canopy |
|
19 |
door |
compound wooden door, security door,aluminium alloy door |
|
20 |
Electrical accessories |
Supply plan, design and construction according to relevant national norms (220V, 50Hz, with lamp, switches and multi-function sockets.) |
|
21 |
Water plumbing accessories |
Supply plan, design and construction according to relevant national norms |
|
22 |
Sanitary ware |
Supply according to customer needs |
|
23 |
Furniture and electrical appliance |
Design according to client's needs |
|
24 |
Design |
roof dead load |
0.3KN/㎡ |
25 |
roof live load |
0.5KN/㎡ |
|
26 |
wind load |
9 degree、wind load:0.35KN/㎡、design speed:24m/S(Chinese standard) |
|
27 |
Earthquake resistant intensity |
6 degree |
|
28 |
used temperature |
Scope::-25℃~+50℃ |
|
29 |
Installation |
Tools |
electric drill, pulling rivet,electric hammer,spanner,screwdriver etc,need power to install the house |
30 |
Efficiency |
Four skilled labor one day can erect 40m2's house body |
|
31 |
Transport |
Container |
each 40ft container could load 130~150㎡ house body material |