Mô tả sản phẩm: Prefabricated Building A Type House
Product profile :
No. |
Sort |
Name |
Specification |
1 |
Product Type |
Degree of Standardization |
custom-made product,design and manufacture according to clients requirement |
2 |
Size |
Length (m): |
No limited, increase expansion joint when length more than 200m. |
3 |
Width(m): |
single span should be less than 12m, an arbitrary width could make by union spans |
|
4 |
Heigth(m): |
single floor≤5m, two or three floors, average height ≤4m |
|
5 |
Roof slope: |
slope is 1:10~1:5 |
|
6 |
Floors: |
less than 3 floors |
|
7 |
Standard equipment |
Ground channel |
Galvanized steel panel compression, thickness is 0.8mm |
8 |
Post |
Inside post is steel square pipe,material is Q235,components surface make antirust process, and decorate with color steel compression parts。 |
|
9 |
Roof beam |
roof truss consist of thin sharpe steel by welding,component surface make antirust process |
|
10 |
Purlin |
purlin is C type steel,material is Q235,components surface make antirust process。 |
|
11 |
Wall beam |
wall beam is C type steel or square pipe,material is Q235,component surface make antirust process |
|
12 |
Floor |
made of floor master beam, secondary beam and floor surface plate(plywood) |
|
13 |
wallboard |
50~150mm thickness double surface color steel sandwich panel, white color |
|
14 |
roof board |
50~150mm thickness double surface color steel corrugated sandwich panel, blue or red color |
|
15 |
door |
color steel sandwich panel door,size:750mm*2000mm; |
|
16 |
window |
PVC sliding window, with steel screen. |
|
17 |
Options |
Ceiling |
mineral wool acoustic panel, aluminum buckle panel, PVC ceiling |
18 |
Elevation floor |
Design based on local weather condition. |
|
19 |
Canopy |
color steel sheet or color steel sandwich panel canopy |
|
20 |
door |
compound wooden door, security door, aluminum alloy door |
|
21 |
Electrical accessories |
Supply plan, design and construction according to relevant national norms (220V, 50Hz, with lamp, switches and multi-function sockets.) |
|
22 |
Water plumbing accessories |
Supply plan, design and construction according to relevant national norms |
|
23 |
Sanitary ware |
Supply according to customer needs |
|
24 |
Furniture and electric appliance |
Supply according to customer needs |
|
25 |
Design technical data |
Roof dead load |
0.3KN/㎡ |
26 |
Roof live load |
0.5KN/㎡ |
|
27 |
Floor dead load |
0.5KN/㎡ |
|
28 |
Floor live load |
2KN/㎡ |
|
29 |
Wind load |
12degree, 120km/h(strengthen the steel frame when the wind is bigger than this data) |
|
30 |
Earthquake resistant intensity |
8 degree |
|
31 |
Used for temperature |
Scope:-25℃~+50℃ (change the design when the temperature is lower than -25℃) |
|
32 |
Installation |
Installation tools |
Electric drill, electric hammer, spanner, screwdriver, pulling rivet etc, house installation need electric power. |
33 |
Installation efficiency |
Four skilled labor one day can erect 40m2's house body |
|
34 |
Transport |
container |
each 40ft container could load 130~150㎡ house body material |