Mô tả sản phẩm: APECH AM-901
1. General DescriptionAM-900/901/902/904 is a digital multimeter equipped with backlight function (except AM-904) and overiload protection circuit. AM-900, AM-901 and AM-904 has LCD display of 3 ½ digits(2000 counts) while AM-902 has LCD display of 3 ¾ digits (4000 counts). The multeimeter performs AC/DC Voltage, DC Current, Resistance, Audible Continuity, Diode, Transistor detecting, etc.
AM-903 is a digital capacitance meter with 3 ½ digits(2000 counts) LCD backlight display. Made with dual slope integrating converter, AM-903 ranges from 200pF to 20 mF .
2. General Characteristics
AM-900 |
AM-901 |
AM-902 |
AM-903 |
AM-904 |
|
Display |
LCD 2000 counts |
LCD 4000 counts |
LCD 2000 counts |
||
Low Battery Indication |
displayed |
||||
Polarity Indication |
“- ”displayed automatically |
||||
Operation Temperature |
0˚C ~ 40˚C |
||||
Storage Temperature |
-10˚C ~ 50˚C |
||||
Battery Type |
9V Or 6F22 x 1PC |
||||
Fuse |
0.2A |
||||
Dimension(HXWXD) |
147x70x35mm |
133x70x30mm |
|||
Weight |
Approx .150g |
Approx . 115g |
|||
Accessories |
Operations Manual, Battery,Test Leads,Temperature Probe(only AM-901) |
||||
Backlight |
Push for 5 seconds |
||||
Data Hold |
“DH” displayed |
||||
Self-recovery Protection |
ü |
ü |
ü |
ü |
3. Technical Specification
1.DC Voltage (only AM-900/901/904)
Range |
Resolution |
Accuracy |
||
AM-901 |
AM-900 |
AM-904 |
||
200 mV |
0.1 mV |
±(0.5% + 5) |
±(0.8% + 10) |
|
2V |
1mV |
|||
20V |
10mV |
|||
200V |
100mV |
|||
600V |
1V |
±(0.8% + 5) |
±(1% + 10) |
Range |
Resolution |
Accuracy |
AM-902 |
||
400mV |
0.1mV |
±(0.8% + 5) |
4V |
1mV |
|
40V |
10mV |
|
400V |
100mV |
|
600V |
1mV |
±(1% + 2) |
Input Impedance:1MΩ
Overload Protection: 250V for range 200mV, 600V for other ranges
2.AC Voltage (only AM-900/901/904)
Range |
Resolution |
Accuracy |
|
AM-901 |
AM-900 |
||
200mV |
0.1mV |
±(1.2% + 10) |
|
2V |
1mV |
Range |
Resolution |
Accuracy |
AM-904 |
||
200V |
100mV |
±(1.5% + 10) |
600V |
1V |
Range |
Resolution |
Accuracy |
AM-902 |
||
4V |
1mV |
±(1.2% + 5) |
40V |
10mV |
|
400V |
100mV |
|
600V |
1V |
±(1.5% + 5) |
Frequency: 40HZ-400HZ
3.DC Current (only AM-900/901/904)
Range |
Resolution |
Accuracy |
||
AM-901 |
AM-900 |
AM-904 |
||
200uA |
100nA |
±(1% + 2) |
±(1.2% + 5) |
|
2mA |
1uA |
±(3% + 2) |
|
|
20mA |
10uA |
±(1.2% + 5) |
||
200mA |
100uA |
±(1.6% + 2) |
±(1.5% + 5) |
|
10A |
10mA |
±(3% + 2) |
±(3% + 10) |
Range |
Resolution |
Accuracy |
AM-902 |
||
40mA |
10uA |
±(1% + 2) |
200mA |
100uA |
±(1.5% + 2) |
4A |
1mA |
±(1.8% +2) |
10A |
10mA |
±(3% + 2) |
Overload Protection:0.2 A self- recovery fuse
4.Resistance (only AM -900/901/904)
Range |
Resolution |
Accuracy |
||
AM-901 |
AM-900 |
AM-904 |
||
200Ω |
0.1Ω |
±(0.8% + 3) |
|
±(1.2% + 5) |
2KΩ |
1Ω |
±(0.8% + 2) |
|
±(1.2% + 5) |
20KΩ |
10Ω |
|||
200KΩ |
100Ω |
|||
2MΩ |
1KΩ |
±(1% + 3) |
±(1.5% + 5) |
Range |
Resolution |
Accuracy |
AM-902 |
||
40mA |
10uA |
±(1.3%+2) |
200mA |
100uA |
±(1.8%+2) |
4A |
1mA |
±(2%+3) |
10A |
10mA |
±(3%+5) |
Overload Protection: 220V
5.Temperature (only AM-901)
Range |
Resolution |
Accuracy |
AM-902 |
||
-30~400oC |
1 oC |
±(1.2%+4) |
401~1000 oC |
1 oC |
±(1.9%+15) |
6.Capacitance (only AM-902/903)
Range |
Resolution |
Accuracy |
AM-902 |
||
50nF |
0.01 nF |
±(3%+5) |
500 nF |
0.1 nF |
|
50uF |
1 nF |
|
50uF |
10 nF |
|
500uF |
100 nF |
Range |
Resolution |
Accuracy |
Test Frequency |
AM-903 |
|||
200pF |
0.1pF |
±(0.6%+2) |
800HZ |
2nF |
1pF |
±(0.6%+2) |
800HZ |
20nF |
10pF |
±(0.6%+2) |
800HZ |
200nF |
100pF |
±(0.6%+2) |
800HZ |
2uF |
1nF |
±(0.6%+2) |
800HZ |
20uF |
10nF |
±(0.6%+2) |
80HZ |
200uF |
100nF |
±(0.6%+2) |
8HZ |
2mF |
1uF |
±(1.2%+2) |
8HZ |
20mF |
10uF |
±(2.5%+3) |
8HZ |
7.hFE(only AM-900/901/904)
Range |
Instruction |
Condition |
hFE |
NPN or PNP ,0-1000 |
Base current 10uA |
8. Diode and Audible Continuity (only AM-900/901/904)
Range |
Instruction |
Condition |
Diode |
Show forward voltage |
Forward Current 1mA Forward Current 0.5mA(AM-904) |
Audible Continuity |
<50Ω, buzz |
OCV 3V OCV 0.5V (AM-904) |
9.Frequency (only AM-902)
Range |
Resolution |
Accuracy |
AM-902 |
||
40Hz |
0.01Hz |
±(0.5% + 3) |
400Hz |
0.1Hz |
|
4kHz |
1Hz |
|
40kHz |
10Hz |
|
400kHz |
100Hz |
|
4MHz |
1kHz |
|
20MHz |
10kHz |