Mô tả sản phẩm: YSI 6920 V2
Medium | Fresh, sea or polluted water | |
Temperature | Operating Storage |
-5 to +50°C -10 to +60°C |
Communications | RS-232, SDI-12 | |
Software | EcoWatch® | |
Dimensions | Diameter Length Weight |
2.85 in, 7.24 cm 18 in, 45.7 cm 4 lbs, 1.8 kg |
Power | External Internal |
12 V DC 8 AA-size alkaline batteries |
Certifications |
CE, EU Battery Compliance, FCC, IP-67, WEEE, and MCERTS |
Range | Resolution | Accuracy | ||
ROX™ Optical Dissolved Oxygen• % Saturation |
0 to 500% | 0.1% | 0 to 200%: ±1% of reading or 1% air saturation, whichever is greater; 200 to 500%: ±15% of reading |
|
ROX™ Optical Dissolved Oxygen• mg/L |
0 to 50 mg/L | 0.01 mg/L | 0 to 20 mg/L: ± 0.1 mg/L or 1% of reading, whichever is greater; 20 to 50 mg/L: ±15% of reading |
|
Dissolved Oxygen•• % Saturation 6562 Rapid Pulse™ Sensor* |
0 to 500% | 0.1% | 0 to 200%: ±2% of reading or 2% air saturation, whichever is greater; 200 to 500%: ±6% of reading |
|
Dissolved Oxygen•• mg/L 6562 Rapid Pulse™ Sensor* |
0 to 50 mg/L | 0.01 mg/L | 0 to 20 mg/L: ± 0.2 mg/L or 2% of reading, whichever is greater; 20 to 50 mg/L: ±6% of reading |
|
Conductivity••• 6560 Sensor* |
0 to 100 mS/cm | 0.001 to 0.1 mS/cm (range dependent) |
±0.5% of reading + 0.001 mS/cm | |
Salinity | 0 to 70 ppt | 0.01 ppt | ±1% of reading or 0.1 ppt, whichever is greater |
|
Temperature 6560 Sensor* |
-5 to +50°C | 0.01°C | ±0.15°C | |
pH 6561 Sensor* |
0 to 14 units | 0.01 unit | ±0.2 unit | |
ORP | -999 to +999 mV | 0.1 mV | ±20 mV | |
Depth | Medium Shallow Vented Level |
0 to 200 ft, 61 m 0 to 30 ft, 9.1 m 0 to 30 ft, 9.1 m |
0.001 ft, 0.001 m 0.001 ft, 0.001 m 0.001 ft, 0.001 m |
±0.4 ft, ±0.12 m ±0.06 ft, ±0.02 m ±0.01 ft, 0.003 m |
Turbidity• 6136 Sensor* |
0 to 1,000 NTU | 0.1 NTU | ±2% of reading or 0.3 NTU, whichever is greater** |
|
Nitrate/nitrogen•••• | 0 to 200 mg/L-N | 0.001 to 1 mg/L-N (range dependent) |
±10% of reading or 2 mg/L, whichever is greater |
|
Ammonium/ammonia/ nitrogen•••• |
0 to 200 mg/L-N | 0.001 to 1 mg/L-N (range dependent) |
±10% of reading or 2 mg/L, whichever is greater |
|
Chloride•••• | 0 to 1000 mg/L | 0.001 to 1 mg/L (range dependent) |
±15% of reading or 5 mg/L, whichever is greater |
|
Rhodamine• | 0-200 μg/L | 0.1 μg/L | ±5% reading or 1 μg/L, whichever is greater |
|
• Maximum depth rating for optical probes is 200 feet, 61 m. Turbidity and Rhodamine are available in a Deep Depth option (0 to 200 m). Anti-fouling optical probes have depth rating of 200 m. •• Rapid Pulse is only available on 6920 V2-1 (one optical port version). ••• Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided. These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989). •••• Freshwater only. Maximum depth rating of 50 feet, 15.2 m. 6600 V2-2 has 3 ISE ports; not available on the 6600V2-4. |
**In YSI AMCO-AEPA Polymer Standards. |
Range | Detection Limit | Resolution | Linearity | |
Blue-Green Algae Phycocyanin• |
~0 to 280,000 cells/mL† 0 to 100 RFU |
~220 cells/mL§ | 1 cell/mL 0.1 RFU |
R2 > 0.9999** |
Blue-Green Algae Phycoerythrin• |
~0 to 200,000 cells/mL† 0 to 100 RFU |
~450 cells/mL§§ | 1 cell/mL 0.1 RFU |
R2 > 0.9999*** |
Chlorophyll• 6025 Sensor* |
~0 to 400 μg/L 0 to 100 RFU |
~0.1 μg/L§§§ | 0.1 μg/L Chl 0.1% RFU |
R2 > 0.9999**** |
• Maximum depth rating for all optical probes is 200 feet, 61 m. Also available in a Deep Depth option (0 to 200 m). RFU = Relative Fluorescence Units |
† Explanation of Ranges can be found in the ‘Principles of Operation’ section of the 6-Series Manual, Rev D. | § Estimated from cultures of Microcystis aeruginosa. §§ Estimated from cultures Synechococcus sp. §§§ Determined from cultures of Isochrysis sp. and chlorophyll a concentration determined via extractions. |
**For serial dilution of Rhodamine WT (0-400 ug/L). ***For serial dilution of Rhodamine WT (0-8 μg/L). ****For serial dilution of Rhodamine WT (0-500 ug/L). |