Mô tả sản phẩm: YSI 6600EDS
Medium | Fresh, sea or polluted water | |
Temperature | Operating Storage |
-5 to +50°C -10 to +60°C |
Communications | RS-232, SDI-12 | |
Software | EcoWatch® | |
Dimensions | Diameter Length, no depth Length, with depth Weight |
3.5 in, 8.9 cm 19.6 in, 49.8 cm 21.6 in, 54.9 cm 7 lbs, 3.18 kg (batteries installed, with depth) |
Power | External Internal |
12 V DC 8 C-size alkaline batteries |
Certifications |
CE, EU Battery Compliance, FCC, IP-67, WEEE, and MCERTS |
Range | Resolution | Accuracy | ||
Dissolved Oxygen•• % Saturation 6562 Rapid Pulse™ Sensor* |
0 to 500% | 0.1% | 0 to 200%: ±2% of reading or 2% air saturation, whichever is greater; 200 to 500%: ±6% of reading |
|
Dissolved Oxygen•• mg/L 6562 Rapid Pulse™ Sensor* |
0 to 50 mg/L | 0.01 mg/L | 0 to 20 mg/L: ± 0.2 mg/L or 2% of reading, whichever is greater; 20 to 50 mg/L: ±6% of reading |
|
Conductivity••• 6560 Sensor* |
0 to 100 mS/cm | 0.001 to 0.1 mS/cm (range dependent) |
±0.5% of reading + 0.001 mS/cm | |
Salinity | 0 to 70 ppt | 0.01 ppt | ±1% of reading or 0.1 ppt, whichever is greater |
|
Temperature 6560 Sensor* |
-5 to +50°C | 0.01°C | ±0.15°C | |
pH 6561 Sensor* |
0 to 14 units | 0.01 unit | ±0.2 unit | |
ORP | -999 to +999 mV | 0.1 mV | ±20 mV | |
Depth | Deep Medium Shallow Vented Level |
0 to 656 ft, 200 m 0 to 200 ft, 61 m 0 to 30 ft, 9.1 m 0 to 30 ft, 9.1 m |
0.001 ft, 0.001 m 0.001 ft, 0.001 m 0.001 ft, 0.001 m 0.001 ft, 0.001 m |
±1 ft, ±0.3 m ±0.4 ft, ±0.12 m ±0.06 ft, ±0.02 m ±0.01 ft, 0.003 m |
Turbidity• 6136 Sensor* |
0 to 1,000 NTU | 0.1 NTU | ±2% of reading or 0.3 NTU, whichever is greater** |
|
Rhodamine• | 0-200 μg/L | 0.1 μg/L | ±5% reading or 1 μg/L, whichever is greater |
|
• Maximum depth rating for optical probes is 200 feet, 61 m. Turbidity and Rhodamine are available in a Deep Depth option (0 to 200 m). Anti-fouling optical probes have depth rating of 200 m. •• Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided. These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989). |
**In YSI AMCO-AEPA Polymer Standards. |
Range | Detection Limit | Resolution | Linearity | |
Blue-Green Algae Phycocyanin• |
~0 to 280,000 cells/mL† 0 to 100 RFU |
~220 cells/mL§ | 1 cell/mL 0.1 RFU |
R2 > 0.9999** |
Blue-Green Algae Phycoerythrin• |
~0 to 200,000 cells/mL† 0 to 100 RFU |
~450 cells/mL§§ | 1 cell/mL 0.1 RFU |
R2 > 0.9999*** |
Chlorophyll• 6025 Sensor* |
~0 to 400 μg/L 0 to 100 RFU |
~0.1 μg/L§§§ | 0.1 μg/L Chl 0.1% RFU |
R2 > 0.9999**** |
• Maximum depth rating for all optical probes is 200 feet, 61 m. Also available in a Deep Depth option (0 to 200 m). RFU = Relative Fluorescence Units |
† Explanation of Ranges can be found in the ‘Principles of Operation’ section of the 6-Series Manual, Rev D. | § Estimated from cultures of Microcystis aeruginosa. §§ Estimated from cultures Synechococcus sp. §§§ Determined from cultures of Isochrysis sp. and chlorophyll a concentration determined via extractions. |
**For serial dilution of Rhodamine WT (0-400 ug/L). ***For serial dilution of Rhodamine WT (0-8 μg/L). ****For serial dilution of Rhodamine WT (0-500 ug/L). |