Mô tả sản phẩm: Fluke 1503
AC/DC Voltage Measurement
|
||
Accuracy | Range | 600.0 V |
Resolution | 0.1 V | |
50 Hz to 400 Hz ± (% of Rdg + Digits) | ± (2 % + 3) | |
Input impedance | 3 MΩ (nominal), < 100 pF | |
Common mode rejection ratio (1 kΩ unbalanced): | > 60 dB at dc, 50 or 60 Hz | |
Overload Protection | 600 V rms or dc | |
Earth bond resistance measurement | ||
Range/Resolution | 20.00 Ω | 0.01 Ω |
200.0 Ω | 0.1 Ω | |
2000 Ω | 1.0 Ω | |
20.00 kΩ | 0.01 kΩ | |
Accuracy | ± (1.5 % + 3) | |
Overload Protection | 2 V rms or dc | |
Open Circuit Test Voltage | > 4.0 V, < 8 V | |
Short circuit current | > 200.0 mA | |
Insulation specifications | ||
Measurement Range | 1507:00:00 | 0.01 MΩ to 10 GΩ |
1503:00:00 | 0.01 MΩ to 2000 MΩ | |
Test voltage | 1507:00:00 | 50 V, 100 V, 250 V, 500 V, 1000 V |
1503:00:00 | 500 V, 1000V | |
Test Voltage Accuracy | + 20 %, - 0 % | |
Short circuit current | 1 mA nominal | |
Auto Discharge | Discharge time < 0.5 second for C = 1 µF or less | |
Live circuit indicator | Inhibit test if terminal voltage > 30 V prior to initialization of test | |
Maximum Capacitive Load | Operable with up to 1 µF load | |
Measure Accuracy: | 50 V: | ±(3 % + 5) |
100 V: | ±(3 % + 5) | |
250 V: | ±(1.5 % + 5) | |
500 V: | ±(1.5 % + 5) | |
1000 V: | ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ | |
General Specifications | ||
Maximum voltage applied to any terminal: | 600 V ac rms or dc | |
Storage Temperature | -40 °C to 60 °C (-40 °F to 140 °F) | |
Operating Temperature | -20 °C to 55 °C (-4 °F to 131 °F) | |
Temperature Coefficient | 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) | |
Relative Humidity | 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) | |
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) | ||
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) | ||
Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument | |
Shock | 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) | |
Electromagnetic compatibility: | In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) | |
Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) | |
Certifications: | CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition | |
Batteries | Four AA batteries (NEDA 15A or IEC LR6) | |
Battery Life | Insulation test use: | Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
Resistance measurements: | Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. | |
Size | 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) | |
Weight | 550 g (1.2 lb) | |
IP Rating | IP40 | |
Altitude | Operating: | 2000 m CAT IV 600 V, 3000 m CAT III 600 V |
Non-operating (storage): | 12,000 m | |
Over-range capability: | 110 % of range | |
Included accessories: | TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe |