Mô tả sản phẩm: Tektronix PA4000 Power Analyzer
Available measurements
VRMS - Volts RMS | VDF – Volts Distortion Factor |
ARMS - Amps RMS | VTIF – Volts Telephone Influence Factor |
WATT – Watts | ATHD – Amps Total Harmonic Distortion |
VA – Volt-Amps | ADF – Amps Distortion Factor |
VAR – Volt-Amps Reactive | ATIF – Amps Telephone Influence Factor |
FRQ – Frequency | VF – Fundamental Volts rms |
PF – Power factor | AF – Fundamental Amps rms |
VPK+ – Volts peak (positive) | IMP – Impedance |
VPK- – Volts peak (negative) | RES – Resistance |
APK+ – Amps peak (positive) | REA – Reactance |
APK- – Amps peak (negative) | HR – Integrator time |
VDC – Volts DC | WHR – Watt Hours |
ADC – Amps DC | VAH – VA Hours |
VRMN – Volts rectified mean | VRH – VAr Hours |
ARMN – Amps rectified mean | AHR – Amp Hours |
VCF – Voltage crest factor | WAV – Average Watts |
ACF – Current crest factor | PFAV – Average Power Factor |
VTHD – Volts Total Harmonic Distortion | CVAR – Correction VArs |
Voltage and current ranges
Voltage Ranges
2000 Vpeak, 1000 Vpeak, 500 Vpeak, 200 Vpeak, 100 Vpeak, 50 Vpeak, 20 Vpeak, 5 Vpeak, 2 Vpeak
Current Ranges (30 A Shunt)
200 Apeak, 100 Apeak, 50 Apeak, 20 Apeak, 10 Apeak, 5 Apeak, 2 Apeak, 1 Apeak, 0.5 Apeak, 0.2 Apeak, 0.1 Apeak
Current Ranges (1 A Shunt)
5 Apeak, 2 Apeak, 1 Apeak, 0.5 Apeak, 0.2 Apeak, 0.1 Apeak, 0.25 Apeak, 0.0125 Apeak, 0.005 Apeak, 0.0025 Apeak
Current Ranges (External Shunt)
3 Vpeak, 1.5 Vpeak, 0.75 Vpeak, 0.3 Vpeak, 0.15 Vpeak, 0.075 Vpeak, 0.03 Vpeak, 0.015 Vpeak, 0.0075 Vpeak
Measurement accuracy – voltage and current
Voltage Accuracy, VRMS ( 45 Hz – 850 Hz )
± 0.04% of Reading ± 0.04% of Range ± 0.02 V
Voltage Accuracy, VRMS ( 10 Hz – 45 Hz, 850 Hz – 1 MHz )
± 0.05% of Reading ± 0.05% of Range ± (0.02*F)% of Reading ± 0.02 V (typical)
Voltage Accuracy, DC
± 0.05% of Reading ± 0.1% of Range ± 0.05 V
Voltage Accuracy, Vrmn
± 0.2% of Reading ± 0.1% of Range ± 0.1 V
Effect of Common Mode (Typical)
1000 V, 60 Hz < 10 mV
100 V, 100 kHz < 50 mV
Current Accuracy, ARMS ( 45 Hz – 850 Hz )
± 0.04% of Reading ± 0.04% of Range ± (20 µV/Zext)
Current Accuracy, ARMS ( 10 Hz – 45 Hz, 850 Hz – 1 MHz )
± 0.05% of Reading ± 0.05% of Range ± (0.02*F)% of Reading ± (20 µV/Zext) (typical)
Current Accuracy, DC
± 0.05% of Reading ± 0.1% of Range ± (50 µV/Zext)
Current Accuracy, ARMS
± 0.2% of Reading ± 0.1% of Range ± (100 µV/Zext)
Measurement accuracy – power
Watts Accuracy
(VRMS acc. x ARMS x PF) ± (ARMS acc. x VRMS x PF) ± (VRMS x ARMS x cos θ -cos { θ± (Vh1ph.err. ± Ah1ph.err.)})
VA Accuracy
(VRMS acc. x ARMS) ± (ARMS acc. x VRMS )
VAR Accuracy
PF Accuracy
Cos θ -cos [ θ± ( Vh1 ph.err± Ah1 ph.err)] ± 0.001
Measurement accuracy – Harmonic magnitude and phase 1
Voltage Harmonics (45 Hz – 850 Hz) (Typical for 10 Hz to 45 Hz and 850 Hz to 1 MHz)
± 0.08% of Reading ± 0.08% of Range ± (0.02*F)% of Reading ± 0.02 V
Voltage Harmonics Phase (45 Hz – 850 Hz) (Typical for 10 Hz to 45 Hz and 850 Hz to 1 MHz)
0.025 ± [ 0.005 * Vrange / Vreading )] ± (0.1 / Vrange) ± ( 0.002 *F )
Current Harmonics (45 Hz – 850 Hz) (Typical for 10 Hz to 45 Hz and 850 Hz to 1 MHz)
± 0.08% of Reading ± 0.08% of Range ± (0.02*F)% of Reading ± (20 µV /Zext)
Current Harmonics Phase (45 Hz – 850 Hz) (Typical for 10 Hz to 45 Hz and 850 Hz to 1 MHz)
0.025 ± [0.005 * Arange / Areading)] ± (0.001 / Arange * Zext)) ± (0.002 *F)
1F is the frequency measured in kHz. In the case of harmonics, F is the harmonic frequency.
Zext is the shunt impedance (0.6 Ω for 1 A shunt, 9.375 mΩ for 30 A shunt). It is assumed that the waveform measured is a sine wave.
Measurement conditions during calibration: Instrument default settings unless otherwise stated, Sine waves applied to V and I inputs, 30 minute warm-up, Temperature 23 °C ±5 °C.