Mô tả sản phẩm: Bộ lưu điện UPS Tescom DS/Power DS320S
• Transformerless UPS topology
• Low input current total harmonic distortion (THD)
• High input power factor
• High efficiency up to %94
• Cold start function
• Static and maintenance by-pass switch
• Output short circuit and overload protection
• External REPO switch input
• 192 events memory (192 events 14.400 alarms)
• Clock and calender (battery supported)
• Automatic battery test ,remaining battery time indicator
• Temperature compensated charge system
• 1 RS232 serial port and 3 dry contact outputs (+2 optional)
• 3 DSP controlled modular structure
• Optional SNMP and MODBUS adaptors
• 2 years warranty
• 10 years spare parts support
• Manufactured under CE,ISO9001,ISO14001,TSE AND GOST international standards
MODEL
|
DS310S
|
DS315S
|
DS320S
|
||||||
Power (kVA)
|
10
|
15
|
20
|
||||||
INPUT
|
|||||||||
Voltage
|
380/400 VAC 3P + N + G ± 20% (415VAC +15%, -25% optional )
|
||||||||
Frequency
|
50Hz. / 60Hz. selectable, ± 5%
|
||||||||
Power factor
|
> 0.99
|
||||||||
Harmonic current distortion (THDI)
|
< 5%
|
||||||||
By-pass voltage
|
380/400 VAC 3 Phase + N , 4 Wires, ± 10%
|
||||||||
Voltage distortion
|
< 10%
|
||||||||
Protection
|
Fuses, Voltage & Frequency Tolerance
|
||||||||
OUTPUT
|
|||||||||
Power (kW)
|
9
|
13,5
|
18
|
||||||
Power factor
|
0,9
|
||||||||
Voltage
|
380/400 VAC 3P + N , ± 1% (415 VAC optional )
|
||||||||
Frequency
|
50Hz. / 60Hz. selectable
|
||||||||
Frequency tolerance
|
Line synchronized: ± 2% / Free running: ± 0,1% (adjustable)
|
||||||||
Efficiency
|
up to 94%
|
||||||||
Crest factor
|
3:1
|
||||||||
Overload protection
|
100% – 125% load: 10 min, 125% – 150% load: 1 min, – > 150% load: by pass
|
||||||||
Protection
|
Fuses,Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
|
||||||||
THD (at 100% linear load)
|
< 3%
|
||||||||
BATTERIES
|
|||||||||
Type
|
VRLA AGM / GEL / NiCd
|
||||||||
Number of batteries
|
60 (± 30) batteries
|
||||||||
Float charging voltage
|
± 405 VDC (adjustable)
|
||||||||
End of discharge voltage
|
± 300 VDC (adjustable)
|
||||||||
Battery cabinet
|
External (attached cabinet at the bottom of UPS)
|
||||||||
Battery ambient temperature
|
25°C
|
||||||||
Battery protection
|
3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
|
||||||||
Automatic battery test
|
Standard: every 72 hours (adjustable)
|
||||||||
GENERAL
|
|||||||||
Standards
|
EN62040-1 , EN62040-2
|
||||||||
User interface
|
4 lines LCD panel, Mimic leds, 5 vector buttons, buzzer
|
||||||||
Indicators
|
P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
|
||||||||
Advanced
|
Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
|
||||||||
Communication
|
RS232 serial port, 4 standard DRY contact alarm relays
|
||||||||
Inputs
|
EPO input
|
||||||||
Genset kit
|
Standard (programmable)
|
||||||||
Software
|
Standard T-Mon UPS Management Software (3 clients + 1 server management)
|
||||||||
Alarm logging
|
Standard: with time & date 512 events
|
||||||||
Protection
|
Power module over temperature, Over current, Temperature high alarms
|
||||||||
Operating temperature
|
0°C – 40°C
|
||||||||
Protection degree
|
IP20
|
||||||||
Relative humidity
|
90% max. (non condensing)
|
||||||||
Altitude
|
< 1000m. above sea level
|
||||||||
Acoustic noise
|
< 55 dBA
|
< 57 dBA
|
< 61 dBA
|
||||||
Weight (kg)
|
42
|
44
|
50
|
||||||
Dimensions (mm) HxWxD
|
700x300x770 (without batt.) / 1000x300x800 (with 5ah batt.) /1170x300x800 (with 7-9ah batt.)
|
||||||||
OPTIONS
|
|||||||||
Different input / output voltage
|
Please ask
|
||||||||
Adaptors
|
SNMP, MODBUS, RS485, Remote panel
|
||||||||
Software
|
T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
|
||||||||
Parallel operation
|
Not Available
|