Mô tả sản phẩm: Bộ lưu điện UPS Tescom 315
• Output isolation transformer
• Up to 91% efficiency
• Static by-pass
• LCD front panel
• 128 events alarm memory (4000 alarms)
• RS232 and relay contacts
• Custom input and output voltage ranges
• SNMP compatible communication
• T-MON remote monitoring software
• Parralel operation up to 4 devices
• High performance at nonlinear loads
• Custom input voltage and frequency ranges
• 2 years warranty
• 10 years spare parts support
• Manufactured according to EC Directive; EN62040
MODEL
|
310
|
315
|
320
|
330
|
340
|
360
|
380
|
Power (kVA)
|
10
|
15
|
20
|
30
|
40
|
60
|
80
|
INPUT
|
|||||||
Voltage
|
220/380 VAC ( 230/400 VAC ) 3 phase + N + G ± 15%
|
||||||
By-pass voltage
|
220/380 VAC ( 230/400 VAC ) 3 phase + N ± 10%
|
||||||
Input frequency
|
50Hz. / 60Hz. ± 5%
|
||||||
OUTPUT
|
|||||||
Power (kW)
|
8
|
12
|
16
|
24
|
32
|
48
|
64
|
Power factor
|
0,8
|
||||||
Voltage
|
220/380 VAC ( 230/400 VAC ) 3 phase + N
|
||||||
Voltage tolerance
|
±1%
|
||||||
Voltage recovery time
|
After step load: max. 25ms
|
||||||
Frequency
|
50Hz. / 60Hz.
|
||||||
Frequency tolerance
|
±2% ( line synchronized ) ±0,2% ( free running )
|
||||||
Efficiency at 100% load
|
88-90%
|
> 90%
|
|||||
Crest Factor
|
3:1
|
||||||
Overload protection
|
(100%-125% load: 10 min.) (125%-150% load: 1 min.) (>150% load: by pass)
|
||||||
Short circuit protection
|
Electronic short circuit protection
|
||||||
THD
|
<%3 ( linear load )
|
||||||
<%5 ( non linear load )
|
|||||||
BATTERIES
|
|||||||
Type
|
Sealed Lead Acid – Maintenance Free
|
||||||
Number of batteries
|
30
|
||||||
Float charging voltage
|
405 VDC
|
||||||
End of discharge voltage
|
300 VDC
|
||||||
Ambient temperature °C
|
25 ºC
|
||||||
Battery protection
|
Automatic circuit breaker
|
||||||
Battery test
|
Automatic / Manuel
|
||||||
GENERAL
|
|||||||
Regulations
|
EN62040-2
|
||||||
Serial communication
|
Dry contacts & RS232
|
||||||
Software
|
T-Mon UPS Management Software (3 clients, +1 server management std.)
|
||||||
Temperature range
|
0 °C – 40 °C
|
||||||
Ventilation
|
Forced air cooling
|
||||||
Relative humidity (non condensed)
|
< 90%
|
||||||
Protection degree
|
IP20
|
||||||
Altitude
|
< 2000m.
|
||||||
Acoustic noise
|
< 56 dBA
|
< 60 dBA
|
|||||
Weight w/o batteries (kg)
|
220
|
260
|
260
|
290
|
415
|
465
|
565
|
Dimensions (mm) WxDxH
|
505x655x1150
|
575x820x1390
|
720x795x1450
|
||||
OPTIONS
|
|||||||
Input transformer
|
Galvanic isolation transformer at the input (in external cabinet)
|
||||||
Input THD
|
10% (with 12 pulse or 18 pulse rectifier, according to UPS range)
|
||||||
%5 (with 18 pulse rectifier, + filter), up to 100kVA
|
|||||||
Input power factor
|
0.95 – 0.98 (with 18 pulse rectifier)
|
||||||
Adaptors
|
SNMP, MODBUS, Remote Mon. Panel, RS485
|
||||||
Parallel operation
|
N+1 (up to 4 units)
|
||||||
In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
|