Automatic Buffer Recognition:Color-coded: 4.01, 7.00, 10.01 pH;
IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45
DIN: 1.09, 4.65, 9.23
User-defined custom buffer sets
Barometric Pressure Measurement:For automatic compensation of DO when using an LDO or LBOD probe
BOD5/CBOD resolution:Available when used with Hach WIMS BOD Manager software
Cable resistance correction:Digital - not needed
Calibration curves display:Calibration summary data logged and displayed
Calibration Intervals/Alerts/Reminder:2 hours 7 days
Compliance:CE
Conductivity Accuracy:± 0.5 % from (1µS/cm - 200 mS/cm)
Conductivity measurement:5 different stability modes
Conductivity Measurement Range:0.01 µS/cm to 400 µS/cm
Conductivity resolution:0.01 µS/cm
Custom Calibration Standards:User-defined standard sets
Data Export:Download via USB connection to PC or flash memory device.
Automatically transfer entire data log or as readings are taken.
Data Memory:500 results
Digital (intelligent) electrode inputs:2
Display:Display readings from one or two probes
Simultaneous readings from two probes (HQ440d only)
pH: pH, mV, temperature
Conductivity: Conductivity, TDS, salinity, resistivity, temperature
LDO: dissolved oxygen, pressure, temperature
LBOD: dissolved oxygen, pressure, temperature
ORP/Redox: mV, temperature
Sodium: Sodium, mV, temperature
Display Lock Function:Continuous measurement or press to read mode available with averaging function for LDO measurement.
Display Type:240 x 160 pixel Display readings from one or two probes
Simultaneous readings from two probes
pH: pH, mV, temperature
Conductivity: Conductivity, TDS, salinity, resistivity, temperature
LDO: dissolved oxygen, pressure, temperature
ORP/Redox: mV, temperature
Sodium: Sodium, mV, temperature
DO Measurement Range:0.01 to 20 mg/L (0 to 200%)
DO Resolution:0.01 mg/L
Fixed Buffer Selection:IUPAC standards
(DIN 19266) or Technical buffer (DIN 19267) or 4-7-10 series or user defined
Inputs:M12 digital (2) for IntelliCAL probes
Interface Languages:13**
Internal Data Storage:500
IP Rating:IP54 (Resistant to spray of water; Dust-proof)
ISE Direct Measurement Range:Yes
ISE Electrode Calibration:Electrode specific - see electrode user instructions
Languages:English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Sweedsh, Czech, Russian
mV Accuracy:± 0.1 mV
mV Measurement at Stable Reading:5 (auto) stabilization settings
mV Measurement Range:-1500 to 1500 mV
mV Resolution:0.1 mV
Operating Error Messages:Text messages displayed
Operating Humidity:90 % relative humidity (non-condensing)
Operating Interface:Keypad
Operating Temperature:5 to 45 °C
ORP Electrode Calibration:Predefined ORP standards (including Zobell's solution)
Outputs:USB to PC / flash memory device
PC Data Transfer Software:Included
pH Measurement at stable reading:5 stabilization settings
Printer:Optional accessory
Salinity Resolution:0.01 ppt
Warranty:3 years
Weight:0.71 lbs. (0.323 kg)