Mô tả sản phẩm: SJ3,5-S1N - Cảm biến tiệm cận - Pepperl+Fuchs Vietnam
SJ3,5-S1N - Cảm biến tiệm cận - Pepperl+Fuchs Vietnam
Nhà sản xuất: Pepperl+Fuchs
Nhà cung cấp: Newskyvn
Model : SJ3,5-S1N
Tên sản phẩm: Cảm biến tiệm cận
Liên hệ để được tư vấn hỗ trợ Mr.Thanh:
Email: quangthanh@newskyvn.com
Zalo: 0965.130.856
Đại lý Pepperl Fuchs Việt Nam
Datasheet excerpt: Technical data of SJ3,5-S1N Pepperl Fuchs
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NAMUR with safety function | |
Slot width | 3.5 mm | |
Depth of immersion (lateral) | 5 ... 7 typ. 6 mm | |
Reference target | 10 x 7 x 0.3 mm3, Al | |
Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. |
|
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) | |
Switching frequency | 0 ... 2500 Hz | |
Hysteresis | with NAMUR switch amplifier: 0.09 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB) with safety switch amplifier 0.05 mm (e. g. Pepperl+Fuchs KFD2-SH-Ex1) |
|
Suitable for 2:1 technology | yes , with reverse polarity protection diode | |
Rate of current rise | 2.1 mA / mm | |
Current consumption | ||
Measuring plate not detected | 0.2 ... 1 mA | |
Measuring plate detected | ≥ 3 mA | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
MTTFd | 11850 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
|
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
|
Approvals and certificates | ||
IECEx approval | ||
Equipment protection level Ga | IECEx PTB 11.0092X | |
Equipment protection level Gb | IECEx PTB 11.0092X | |
Equipment protection level Da | IECEx PTB 11.0092X | |
Equipment protection level Mb | IECEx PTB 11.0092X | |
ATEX approval | ||
Equipment protection level Ga | PTB 00 ATEX 2049 X | |
Equipment protection level Gb | PTB 00 ATEX 2049 X | |
Equipment protection level Da | PTB 00 ATEX 2049 X | |
UL approval | cULus Listed, General Purpose | |
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0454 | |
CCC approval | ||
Hazardous Location | 2020322315002308 | |
NEPSI approval | ||
NEPSI certificate | GYJ16.1392X | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | flexible leads LiY | |
Housing material | PBT | |
Degree of protection | IP67 | |
Cable | ||
Cable diameter | 1.1 mm ± 0.1 mm | |
Bending radius | > 10 x cable diameter | |
Material | PVC | |
Core cross section | 0.14 mm2 | |
Length | 500 mm | |
Note | only for non-ferrous metal Adjustable stop |
|
General information | ||
Use in the hazardous area | see instruction manuals |
Classifications
System | Classcode |
---|---|
ECLASS 11.0 | 27270101 |
ECLASS 10.0.1 | 27270101 |
ECLASS 9.0 | 27270101 |
ECLASS 8.0 | 27270101 |
ECLASS 5.1 | 27270101 |
ETIM 8.0 | EC002714 |
ETIM 7.0 | EC002714 |
ETIM 6.0 | EC002714 |
ETIM 5.0 | EC002714 |
UNSPSC 12.1 | 39121550 |