Phụ Kiện Ph Và Orp Bamo, Đại Lý Bamo Viet Nam

Liên hệ

451/25 Tô Hiến Thành, P.14, Quân 10, Tp.hcm

Phụ kiện pH và ORP Bamo, Đại lý Bamo Viet Nam

Model:  pH and ORP Accessories

Hãng: Bamo

PHỤ KIỆN BAO GỒM:


Đầu nối đồng trục

Đầu nối đúc

Cáp 9060 

Hộp nối 9055

Dung dịch



 


Hotline: 0933.911.903


Liên hệ với chúng tôi để có thêm thông tin và giá tốt nhất!


 

pH and ORP accessories

 







pH accessories


 

 

 


 

Coaxial connectors (DIN)

To connect cable 9060 type on any pH/ mV-meters or electrodes with head S7 type.
This patented connector allows connection with cables (further on), on site with only a soldering iron thin pane and a wire stripper.


DIN molded connector 9054 on cable 9060 for pH

Connection electrode/ pH-meter. Convenient distances from power supply cables and process signals must be respected.


Cable 9060 special for pH - Triple coaxial cable 9061 (double shield)

9060: Connection electrode/ pH-meter for distances less than 30 m. Convenient distances from power supply cables and process signals must be respected.

9061: Connection electrode/ pH-meter for distances over 30 m and/or areas where electrical interferences exist. This cable 9061 has a second shield to protect the measuring signal. The second shield (external) must be connected to ground and only on monitor side. Convenient distances from power supply cables and process signals must be respected.

9059: Workshop mounting of any connector 9054, 9050, BNC, etc. on the cable of your choice (Code 160400)


JUNCTION BOX 9055

IP 55 case, 2 plugs S7, shielded inside


Buffer solutions

pH 7 buffer, 100 ml
pH 4 buffer, 100 ml
pH 10 buffer, 100 ml

rH 200 mV solution, 100 ml

KCl electrolyte, 500 ml

Coaxial connectors (DIN)

(1) & (2): To connect cable 9060 type on any pH/ mV-meters or electrodes with head S7 type.
This patented connector allows connection with cables below, on site with only a soldering iron thin pane and a wire stripper.

CodeReferenceDescription
160.2009054Coaxial connector (to electrode or pH-meter)
160.1009050DIN connector, metal for pH-meter
 
DIN molded connector 9054 on cable 9060 for pH

(3): Connection electrode / pH-meter. Convenient distances from power supply cables and process signals must be respected.

CodeDescription
160.205DIN molded connector 9054 on 5 m long cable 9060 type
160.210DIN molded connector 9054 on 10 m long cable 9060 type
160.220DIN molded connector 9054 on 20 m long cable 9060 type
160.230DIN molded connector 9054 on 30 m long cable 9060 type
 
Cable 9060 special for pH - Triple coaxial cable 9061 (double

9060: Connection electrode / pH-meter for distances less than 30 m. Convenient distances from power supply cables and process signals must be respected.
9061: Connection electrode / pH-meter for distances over 30 m and/or areas where electrical interferences exist.
This cable 9061 has a second shield to protect the measuring signal.
The second shield (external) must be connected to ground and only on monitor side.
Convenient distances from power supply cables and process signals must be respected.
9059: Workshop mounting of any connector 9054, 9050, BNC, etc. on the cable of your choice (Code 160 400)

CodeReferenceDescription
160.3009060Coaxial cable for pH
160.3109061Triple coaxial cable (double shield)
 
Junction box 9055
(4): IP 55, case, 2 plugs S7, shielded inside
CodeReferenceDescription
160.2509055Junction box
 
(5) : Buffer solutions
 
CodeReferenceDescription
160.5009005KCl electrolyte, 500 ml
160.6079011pH 7 buffer, 100 ml
160.6049012pH 4 buffer, 100 ml
160.6099013pH 10 buffer, 100 ml
160.6169016rH 200 mV solution, 100 ml




Bình luận

HẾT HẠN

0933 911 903
Mã số : 17353151
Địa điểm : Hồ Chí Minh
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 30/12/2023
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!

Gợi ý cho bạn