Model: pH and ORP Accessories
Hãng: Bamo
PHỤ KIỆN BAO GỒM:
pH accessories |
To connect cable 9060 type on any pH/ mV-meters or electrodes with head S7 type.
This patented connector allows connection with cables (further on), on site with only a soldering iron thin pane and a wire stripper.
Connection electrode/ pH-meter. Convenient distances from power supply cables and process signals must be respected.
9060: Connection electrode/ pH-meter for distances less than 30 m. Convenient distances from power supply cables and process signals must be respected.
9061: Connection electrode/ pH-meter for distances over 30 m and/or areas where electrical interferences exist. This cable 9061 has a second shield to protect the measuring signal. The second shield (external) must be connected to ground and only on monitor side. Convenient distances from power supply cables and process signals must be respected.
9059: Workshop mounting of any connector 9054, 9050, BNC, etc. on the cable of your choice (Code 160400)
IP 55 case, 2 plugs S7, shielded inside
pH 7 buffer, 100 ml
pH 4 buffer, 100 ml
pH 10 buffer, 100 ml
rH 200 mV solution, 100 ml
KCl electrolyte, 500 ml
Coaxial connectors (DIN) | ||||||||
(1) & (2): To connect cable 9060 type on any pH/ mV-meters or electrodes with head S7 type. This patented connector allows connection with cables below, on site with only a soldering iron thin pane and a wire stripper. | ||||||||
Code | Reference | Description | ||||||
160.200 | 9054 | Coaxial connector (to electrode or pH-meter) | ||||||
160.100 | 9050 | DIN connector, metal for pH-meter | ||||||
DIN molded connector 9054 on cable 9060 for pH | ||||||||
(3): Connection electrode / pH-meter. Convenient distances from power supply cables and process signals must be respected. | ||||||||
Code | Description | |||||||
160.205 | DIN molded connector 9054 on 5 m long cable 9060 type | |||||||
160.210 | DIN molded connector 9054 on 10 m long cable 9060 type | |||||||
160.220 | DIN molded connector 9054 on 20 m long cable 9060 type | |||||||
160.230 | DIN molded connector 9054 on 30 m long cable 9060 type | |||||||
Cable 9060 special for pH - Triple coaxial cable 9061 (double | ||||||||
9060: Connection electrode / pH-meter for distances less than 30 m. Convenient distances from power supply cables and process signals must be respected. 9061: Connection electrode / pH-meter for distances over 30 m and/or areas where electrical interferences exist. This cable 9061 has a second shield to protect the measuring signal. The second shield (external) must be connected to ground and only on monitor side. Convenient distances from power supply cables and process signals must be respected. 9059: Workshop mounting of any connector 9054, 9050, BNC, etc. on the cable of your choice (Code 160 400) | ||||||||
Code | Reference | Description | ||||||
160.300 | 9060 | Coaxial cable for pH | ||||||
160.310 | 9061 | Triple coaxial cable (double shield) | ||||||
Junction box 9055 | ||||||||
(4): IP 55, case, 2 plugs S7, shielded inside | ||||||||
Code | Reference | Description | ||||||
160.250 | 9055 | Junction box | ||||||
(5) : Buffer solutions | ||||||||
Code | Reference | Description | ||||||
160.500 | 9005 | KCl electrolyte, 500 ml | ||||||
160.607 | 9011 | pH 7 buffer, 100 ml | ||||||
160.604 | 9012 | pH 4 buffer, 100 ml | ||||||
160.609 | 9013 | pH 10 buffer, 100 ml | ||||||
160.616 | 9016 | rH 200 mV solution, 100 ml |
Bình luận