Liên hệ
314 Trần Khát Chân - Hai Bà Trưng - Hà Nội
AMF900
AMF900 Series is a flange type Electromagnetic Flowmeter ideal for conductive liquids. It comes in sizes from 6 to 2000mm.
AMF900 is widely used for tap-water, waste water, food & beverage
Pulp & Paper and many other industrial fluid.
AMF900 Series electromanetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic Flowmeter.
FEATURES
Various liner and electrode can be selected to satisfy most industrial applications
Flow Velocity range:0-12 m/s, with precisely measure for low flow applications
It comes any flanges such as ,ANSI, DIN, JIS... etc
Excellent for high pressure application
Protection class: IP68 is available, and the sensor can sink into the water
FEP Liner is suit for vacuum tube
High accuracy of +/-0.4% value of reading (or +/-0.2% value of reading)
With Forward/Reverse flowrate measure function
SPECIFICATION
Size: | Electrode & Grounding: | |
6,10,15,20, 25,32,40,50,65,80,100,125 | Stainless Steel 316L | |
150,200,250,300,350,400,450,500,600 | Hastelloy B | |
700,800,900,1000,1200,1400,1600 | Hastelloy C | |
1800,2000 mm | Titanium | |
Measuring Range: | Tantalum | |
Velocity 0 - 0.25 m/s min. | Platinum | |
0 - 12 m/s max. | Tungsten Carbide | |
Material: | Cable Entry: | |
Measuring Tube | PG11 | |
Stainless Steel 304 | Ambient Temperature: | |
Flange |
| |
Carbon Steel (standard) | Process Connection: | |
Stainless Steel 304(Option) | Flange | |
Stainless Steel 316,316L(Option) | Flanges Type: | |
Coil Housing | JIS 10K / JIS 20K / JIS 40K | |
Carbon Steel (standard) | ANSI 150# / ANSI 300# / ANSI 600# | |
Stainless Steel 304(Option) | DIN PN 10 / PN 16 / PN25 / PN 40 | |
Stainless Steel 316,316L(Option) | Grounding Resistance: | |
Liner: | Must be less then 10 | |
Polyurethane(25-600 mm) | Accuracy: | |
Neoprene(50-2000 mm) | +/-0.4% read-out values(Velocity>=0.5 m/s) | |
FEP(6-300 mm) | +/-0.0025 m/s (Velocity < 0.5 m/s) | |
PTFE(25-800 mm) | +/-0.2% read-out values | |
PFA(6-300 mm) | (suit for AMC3100 Converter only) | |
IP 68 | Temperature: | |
IP 68 (Submersible) |
| |
Conductivity: |
| |
More than 5 uS/cm |
| |
Explosion Proof: |
| |
Exd(ib)ibqIIBT5 (with AMC3100 only) | Max. Pressure: | |
| 350 Kg/cm2 |
AMF500
AMF500 Series is a wafer type electromagnetic Flowmeter ideal for conductive liquids. It comes in sizes from 25 to 200 mm.
AMF500 is widely used for tap-water, waste water, food & beverage, Pulp & Paper and many other industrial fluid.
AMF500 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic Flowmeter.
FEATURES
Light and compact version
Flow Velocity range:0-12 m/s, with precisely measure for low flow applications
It comes any flanges such as ANSI, DIN, JIS... etc
Excellent for high pressure application
Protection class: IP68 is available, and the sensor can sink into the water
FEP Liner is suit for vacuum tube
High accuracy of +/-0.4% value of reading.(or+/-0.2% value of reading)
With Forward/Reverse flowrate measure function
SPECIFICATION
Size: | Cable Entry: | |
25,32,40,50,65,80,100,125,150,200 | PG11 | |
Measuring Range: | Ambient Temperature: | |
Velocity 0-0.25 m/s min. |
| |
0-12 m/s max. | Process Connection: | |
Material: | Wafer | |
Measuring Tube | Flanges type: | |
Stainless Steel 304 | JIS 10K / JIS 20K / JIS 40K | |
Coil Housing | ANSI 150# / ANSI 300# / ANSI 600# | |
Carbon Steel (standard) | DIN PN 10 / PN 16 / PN25 / PN 40 | |
Stainless Steel 304(Option) | Grounding Resistance: | |
Stainless Steel 316(Option) | Must be less then 10 | |
Liner: | Accuracy: | |
FEP | +/-0.5% read-out values (Velocity>=0.5 m/s) | |
Protection: | +/-0.2% read-out values | |
IP 68 | (Suit for AMC3100 Converter only) | |
IP 68(Submersible) | +/-0.0025 m/s (Velocity < 0.5 m/s) | |
Conductivity: | Temperature: | |
More than 5 uS/cm |
| |
Electrode & Grounding: | Max. Pressure: | |
Stainless Steel 316L | 16 Kg/cm2 (standard) | |
Hastelloy B | 40 Kg/cm2(option) | |
Hastelloy C | Explosion Proof: | |
Titanium | Exd(ib)ibqIIBT5 | |
Tantalum | (with AMC3100 only) | |
Tungsten Carbide |
| |
Platinum |
|
AMF601
AMF601 Series is a sanitary type electromagnetic Flowmeter ideal for conductive liquids. It comes in sizes from 25 to 100 mm.
The AMF601 is widely used for drink water, Milk , food & beverage juice and many other industrial fluid.
AMF601 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic Flowmeter.
FEATURES
Light and compact version
Flow Velocity range:0-12 m/s, with precisely measure for low flow applications
IDF Tri-Clamp or Union screw Connection
It excellent for high pressure application
Protection class: IP68 is available, and the sensor can sink into the water
PTFE Liner is suit for vacuum tube
High accuracy of +/-0.4% value of reading (or+/-0.2% value of reading)
With Forward/Reverse flowrate measure function
SPECIFICATION
Size: | Cable Entry: | |
25mm , 32mm, 40mm, 50mm | PG11 | |
65mm, 80mm, 100mm | Ambient Temperature: | |
1", 1-1/4", 1-1/2", 2", 3" , 4" |
| |
Measuring Range: | Process Connection: | |
Velocity 0-0.25 m/s min. | IDF Tri-Clamp | |
0-12 m/s max. | Union Screw | |
Material: | Grounding Resistance: | |
Tube & Connection | Must be less then 10 | |
Stainless Steel 304 or 316 | Accuracy: | |
Coil Housing | +/-0.5% reading (Velocity>=0.5m/s) | |
Stainless Steel 304 (standard) | +/-0.2% reading | |
Stainless Steel 316(Option) | (Suit for AMC3100 Converter only) | |
Liner | +/-0.0025 m/s (Velocity < 0.5 m/s) | |
PTFE | Temperature: | |
Electrode |
| |
Stainless Steel 316L | Max. Pressure: | |
Hastelloy B | 10 Kg/cm2 (standard) | |
Hastelloy C | 40 Kg/cm2(option) | |
Titanium | Explosion Proof: | |
Tantalum | Exd(ib)ibqIIBT5 | |
Tungsten Carbide | (with AMC3100 only) | |
Platinum |
| |
Protection: |
| |
IP 68 |
| |
IP68(Submersible) |
| |
Conductivity: |
| |
More than 5 uS/cm |
|
AUF610series
AUF610series is a portable transit-time ultrasonic flowmeter with clamp-on transducers for non-invasive liquid measurement.
Based on microprocessor,field programmable flow measurement technique allows no interruption to the process flow and has low installation costs.
FEATURES
4 line LCD to display flowrate,totalizer signal condition..Etc
The flowmeter is designed in high accuracy +/-1.0%
Small sized(210 * 90* 30mm) light-weight(500g)
Wide range, Velocities( 0.01 ~ +/- 32 m/s)
Ni-MH Battery support at least 10 hours continuous operation
Maximum temperature 160 oC
Transducers for pipes size from 15 to 6000 mm((1/2" ~ 240")
Transducers contains magnet devise, which can installed on metal pipe without mounting belt
Data logger which records flowrate,date,total flow ,signal condition..Etc
Response time less than 1 second
SPECIFICATION
Measuring Principle: | Keypad: | |
Transit time difference | 18 Key with tactile action | |
Pipe Size: | Response Time: | |
S Type : 15 mm ~ 100 mm (1/2" ~ 4") | Less than 1 second | |
M Type : 50 mm ~ 1000 mm (2" ~ 40") | Flow Velocity: | |
L Type : 300 mm ~ 6000 mm (12" ~ 240") | 0.01 ~ +/- 32 m/s | |
HS Type : 15 mm ~ 100 mm (1/2" ~ 4") | Resolution: | |
HM Type : 50 mm ~ 1000 mm (2" ~ 40") | 0.0001 m/s | |
Pipe Material: | Ambient Temperature: | |
Cast Iron, Stainless Steel, Ductile Iron |
| |
Copper, PVC, Aluminum, Asbestos | Ambient Humidity: | |
Fiberglass... Etc | 90% RH or Less | |
Liner Material: | Built-in Battery: | |
Tar Epoxy, Rubber, Mortar, Polypropylene, | Ni-MH Battery | |
Polystyrol, Polystyrene, Polyester, Ebonite, | Operation Time: | |
Polyethylene, Teflon... Etc | > 10 Hours | |
Display: | Charger: | |
4 Line LCD with illumination | 90 ~ 260Vac 50/60 Hz, 8-12 Hr charging | |
Flowrate | Data Storage: | |
5 digit with decimal point | Operation parameters and totalization | |
Totalizer | Data are stored by EEPROM for more | |
8 digit, Forward, Reverse & Net values | than 10 years | |
Engineer Unit | Data Logger: | |
M3, Liter, US Gallon, Imperial Gallon, | 64 data include flowrate, totalizer, | |
Million Gallon, Cubic Feet, US Barrels, | time, date | |
Imperial Barrels, Oil Barrel | Output: | |
Time Unit | Pulse (Open collector) | |
Second, Minute, Hour, Day | Alarm: | |
Other | High/Low with buzzer | |
Velocity, Date, Time, Signal condition | Power consumption: | |
Accuracy: | Less than 2W | |
+/- 1% ~ +/- 2% value of reading(0.5 ~ 30 m/s) | Dimension: | |
+/-0.5% value of reading (online calibration) | 210 * 90 * 30 mm | |
Repeatability: | Weight: | |
+/-0.2% value of reading | 0.5 Kg | |
| Enclosure: | |
| Converter | |
| IP65 | |
| Sensor | |
| IP68(Submersible) |
AUF760
ALIASONIC AUF760 series is a fixed mounted, transit-time ultrasonic flowmeter, flange end transducers for non-invasive liquid measurement.
Our microprocessor based, user friendly, field programmable flow measurement technique allows no interruption of the process flow and has low installation costs.
FEATURES
4 line LCD display with flowrate, totalizer & signal condition
Stores up 64 Day/Month/Year Totalizer daily value
Batch control function
Wide range velocities of 0.01 ~ +/- 32 m/s
Pipe size from 100 to 1000 mm
High accuracy of +/-1% of reading
Data logger function, include date, totalizer, signal condition... etc
Response time less than 1 second
SPECIFICATION
Measuring Principle: | Keypad: |
Transit time difference | 16 Key with tactile action |
Pipe Size: | Response Time: |
100 mm ~ 1000 mm | Less than 1 second |
4" ~ 40" | Flow Velocity: |
Material: | 0.01 ~ +/- 32 m/s |
Carbon Steel / Stainless Steel 304 | Resolution: |
Stainless Steel316 | 0.0001 m/s |
Process Connection: | Ambient Temperature: |
Flange | -20 ~ +50 oC |
Flanges type: | Mounting: |
JIS 7.5K / JIS 10K / JIS 20K / JIS 40K | wall mounting |
ANSI 150# / ANSI 300# / ANSI 600# | Max. Cable Length: |
DIN PN 10 / PN 16 / PN25 / PN 40 | 150 M |
Max. Pressure: | Power Consumption: |
40 Kg/cm2 | Less than 2W |
Process Temperature: | Power Supply: |
-20 ~ +110 oC | 90 ~ 260Vac 50/60 Hz/ 24Vdc |
Display: | Data Storage: |
4 Line LCD with illumination. | Operation parameters and totalization |
Flowrate | date are stored by EEPROM for more |
5 digit with decimal point | than 10 years |
Totalizer | Output: |
8 digit, Forward, Reverse & Net values. | 4-20 mA or 0-20 mA |
Engineer Unit | Pulse Output: |
M3, Liter, US Gallon, Imperial Gallon, | 1- 9999 Hz |
Million Gallon, Cubic Feet, US Barrels, | Data Logger: |
Imperial Barrels, Oil Barrel. | 64 data include flowrate, totalizer, |
Time Unit | time, date. |
Second, Minute, Hour, Day. | Alarm: |
Other | High/Low with buzzer |
Velocity, Date, Time, Signal condition. | Communication: |
Accuracy: | RS-232 |
+/- 1.0% of reading | Dimension: |
Repeatability: | 235 * 205 * 95 mm |
+/-0.2% of reading | Weight: |
| 1.5 Kg (Converter) |
| Enclosure: |
| Converter |
| IP65 |
| Sensor |
| IP68(Submersible) |
AUF750
AUF750 series is a fixed mounted, transit-time ultrasonic Flowmeter, with clamp-on transducers for non-invasive liquid measurement.
Our microprocessor based, user friendly, field programmable flow measurement technique allows no interruption of the process flow and has low installation costs.
FEATURES
|
4 line LCD display with flowrate, totalizer & signal condition
Stores up 64 Day/Month/Year Totalizer daily value
Batch control function
Wide range velocities of 0.01 ~ +/- 32 m/s
Transducers for pipe size from 15 to 6000 mm
High accuracy of +/-0.5% of reading
Transducers include magnet devise, for installation on metal pipe without mounting belt
Data logger function, include date, totalizer, signal condition... etc
Response time less than 1 second
SPECIFICATION
Measuring Principle: | Keypad: |
Transit time difference | 16 Key with tactile action |
Pipe Size: | Response Time: |
S Type : 15 mm ~ 100 mm (1/2" ~ 4") | Less than 1 second |
M Type : 50 mm ~ 1000 mm (2" ~ 40") | Flow Velocity: |
L Type : 300 mm ~ 6000 mm (12" ~ 240") | 0.01 ~ +/- 32 m/s |
HS Type : 15 mm ~ 100 mm (½" ~ 4") | Resolution: |
HM Type: 50 mm ~ 1000 mm (2" ~ 40") | 0.0001 m/s |
Pipe Material: | Ambient Temperature: |
Cast Iron, Stainless Steel, Ductile Iron | -20 ~ +50 oC |
Copper, PVC, Aluminum, Fiberglass... etc. | Mounting: |
Liner Material: | wall mounting |
Tar Epoxy, Rubber, Mortar, Polypropylene, | Max. Cable Length: |
Polystyrol, Polyethylene, Teflon¡ etc | 150 M |
Display: | Power Consumption: |
4 Line LCD with illumination. | Less than 2W |
Flowrate | Power Supply: |
5 digit with decimal point | 90 ~ 260Vac 50/60 Hz or 8-36Vdc |
Totalizer | Data Storage: |
8 digit, Forward, Reverse & Net values. | Operation parameters and totalization |
Engineer Unit | date are stored by EEPROM for more |
M3, Liter, US Gallon, Imperial Gallon, | than 10 years |
Million Gallon, Cubic Feet, US Barrels, | Output: |
Imperial Barrels, Oil Barrel. | 4-20 mA or 0-20 mA |
Time Unit | Pulse Output: |
Second, Minute, Hour, Day. | 1- 9999 Hz |
Other | Data Logger: |
Velocity, Date, Time, Signal condition. | 64 data include flowrate, totalizer, |
Accuracy: | time, date. |
+/- 1% ~ +/- 2% of reading(0.5 ~ 30 m/s) | Alarm: |
+/- 0.5% of reading (online calibration) | High/Low with buzzer |
Repeatability: | Communication: |
+/-0.2% of reading | RS-232 |
Temperature Input: | Dimension: |
4-20 mA * 2 points for BTU calculation | 235 * 205 * 95 mm |
Function | Weight: |
T, Measurements for Thermal Energy | 1.5 Kg |
| Enclosure: |
| Converter |
| IP65 |
| Sensor |
| IP68(Submersible) |
AUF600
ALIASONIC AUF600 series is a portable transit-time ultrasonic flowmeter with clamp-on transducers for non-invasive liquid measurement.
Based on microprocessor and programmable flow measurement technique which allows no interruption of the process flow and has low installation costs.
FEATURES
4 line LCD display flowrate, totalizer & signal condition
The flowmeter is designed with high accuracy +/-1.0%
Small sized(200 * 92 * 32mm) and light-weight(538 g)
Wide range, Velocities( 0.01 ~ +/- 32 m/s)
Ni-MH Battery could support over 10 hours continuous operation
Transducers suit for pipe sizes from 13 to 6000 mm
Transducers include magnet devise, which can install on Metal pipe without
mounting belt
Data logger which records flowrate, date, total flow ,signal condition... etc
Response time less than 1 second
SPECIFICATION
Measuring Principle: | Keypad: | |
Transit time difference | 18 Key with tactile action | |
Pipe Size: | Response Time: | |
SS Type : 15 mm ~ 100 mm (1/2" ~ 4") | Less than 1 second | |
MS Type : 50 mm ~ 700 mm (2" ~ 28") | Flow Velocity: | |
M Type : 50 mm ~ 700 mm (2" ~ 28") | 0.01 ~ +/- 32 m/s | |
L Type : 300 mm ~ 6000 mm (12" ~ 240") | Resolution: | |
Pipe Material: | 0.0001 m/s | |
Cast Iron, Stainless Steel, Ductile Iron | Ambient Temperature: | |
Copper, PVC, Aluminum, Asbestos |
| |
Fiberglass... etc | Ambient Humidity: | |
Liner Material: | 90% RH or Less | |
Tar Epoxy, Rubber, Mortar, Polypropylene, | Built-in Battery: | |
Polystyrol, Polystyrene, Polyester, Ebonite, | Ni-MH Battery | |
Polyethylene, Teflon... etc | Operation Time: | |
Display: | > 10 Hours | |
4 Line LCD with illumination | Charger: | |
Flowrate | 90 ~ 260Vac 50/60 Hz, 8-12 Hr charging | |
5 digit with decimal point | Data Storage: | |
Totalizer | Operation parameters and totalization | |
8 digit, Forward, Reverse & Net values | data are stored by EEPROM for more | |
Engineer Unit | than 10 years | |
M3, Liter, US Gallon, Imperial Gallon, | Data Logger: | |
Million Gallon, Cubic Feet, US Barrels, | 64 data include flowrate, totalizer, | |
Imperial Barrels, Oil Barrel | time, date | |
Time Unit | Alarm: | |
Second, Minute, Hour, Day | High/Low with buzzer | |
Other | Power consumption: | |
Velocity, Date, Time, Signal condition | Less than 2W | |
Accuracy: | Dimension: | |
+/- 1% ~ +/- 2% of reading(0.5 ~ 30 m/s) | 200 * 92 * 32 mm | |
+/- 0.5% of reading (online calibration) | Weight: | |
Repeatability: | 0.54 Kg | |
+/-0.2% of reading | Enclosure: | |
| Converter | |
| IP65 | |
| Sensor | |
| IP68(Submersible) |
AVF7000
ALIAVTX AVF7000 is a Vortex Flowmeter based on Von Karman theory of vortices generated by a bluff body in the pipe. The number of vortices are linearly proportional to the volumetric flow in the pipe.
The AVF7000 is versatile flowmeter widely used for Gases, Steam & Liquid applications. There are no moving parts and comes with either Flange or wafer connection. Standard configuration have local indication for flowrate and total flow as well as a 4-20mA output functions. The microprocessor design can filter out erroneous signals as well as interfence caused by pipe vibration.
FEATURES
Simplified setup and self-diagnostic functions
Auto. Temperature & Pressure compensation
4-20 mA and pulse outputs, user selectable
a very wide selection of sizes
Wide temperature range which can up to 420 Deg. C
Non-volatile memory for setup and calibration
SPECIFICATION
Size: | Local display: |
10,15,20,25,32,40,50,65,80,100,125,150 | 4 lines LCD |
200,250,300,350,400,450,500mm | 4 digit flowrate |
Measuring Range: | 8 digit Totalizer |
Steam - 1.6 to 540,000 Kg/Hr | Current output: |
Gas - 3 to 46,000 M3/Hr | 4-20 mA (2 wire) |
Liquid - 0.3 to 4950 M3/Hr | Load |
Material: | 600 Ohm |
Stainless Steel 301 / 304 / 316 | Pulse output: |
Accuracy: | Scale Pulse(3 wire) |
Liquid | Rating |
+/-0.7% value of reading | 3 to 30VDC, 20mA Max. |
Gas & Steam | Communication: |
+/-1.0% value of reading | RS485 |
Repeatability: | Data storage: |
+/-0.2% value of reading | Operation Parameter and Totalizer |
Process Connection: | Figures are stored by EEPROM for more |
Flange / Wafer | than 10 years |
Flanges type | Housing Material: |
JIS 10K / JIS 20K / JIS 40K | Aluminum Alloy |
ANSI 150# / ANSI 300# / ANSI 600# | Cable Entry: |
DIN PIN 10 / PN 16 / PN25 / PN 40 | 2 X M20 *1.5 |
Wafer type | Power supply: |
DN40~DN250 | 12-36 VDC |
without Temperature / Pressure Sensor | Ni-MH Battery(3 years working Hours) |
Temperature: | Key Pad: |
-40 ~ +280 Deg. C (Standard) | 4 keys from internal for Programming |
-40 ~ +420 Deg. C (Optional) | and display control |
Ambient Temperature: | Option: |
-20 ~ +60 Deg. C | Pressure Sensor |
Pressure: | Pressure compensation |
78 Kg/cm2 (Max.) | Signal output |
Protection: | 0-30 mV DC(20 uA Power supply) |
IP 65 | Temperature sensor |
Explosion Proof, Exd IIC T6 | Temperature compensation |
Intrinsically Safe, Eex ia IIC T4 | Signal output |
| PT100 ohm (3 wires) |
AVF250
ALIAVA AVF250 Series is a flowmeter commonly used in Auto-industry process control. It''s with small volume, wide range and easily operation.
It could also measure liquid, gas and steam flowrate, especially fit for small flowrate application.
FEATURES
4 digit flowrate & 8 digit totalizer
Local indication without auxiliary power
4-20 mA & Scale pulse output
Low pressure lost on gas and steam application
Damper for Gas/Steam application
Consistent overall length
Heating jacket design
Intrinsically safe & explosion proof for hazardous area
SPECIFICATION
Size: | Local Display: |
15,20,25,40,50,65,80,100,125,150,200 mm | Mechanical Indicator (standard) |
Measuring Range: | Digit Display |
Liquid - 1 ~ 200000 Liter/Hr | 4 Digit Flowrate |
HẾT HẠN
Mã số : | 5851803 |
Địa điểm : | Hà Nội |
Hình thức : | Cần bán |
Tình trạng : | Hàng mới |
Hết hạn : | 31/12/2020 |
Loại tin : | Thường |
Gợi ý cho bạn
Bình luận