1 triệu
Số 66 Lô B2 Khu Đô Thị Mới Đại Kim - P. Đại Kim - Q. Hoàng Mai
• Transformerless UPS topology
• Low input current total harmonic distortion (THD)
• High input power factor
• High efficiency up to %94
• Cold start function
• Static and maintenance by-pass switch
• Output short circuit and overload protection
• External REPO switch input
• 192 events memory (192 events 14.400 alarms)
• Clock and calender (battery supported)
• Automatic battery test ,remaining battery time indicator
• Temperature compensated charge system
• 1 RS232 serial port and 3 dry contact outputs (+2 optional)
• 3 DSP controlled modular structure
• Optional SNMP and MODBUS adaptors
• 2 years warranty
• 10 years spare parts support
• Manufactured under CE,ISO9001,ISO14001,TSE AND GOST international standards
MODEL | DS310S | DS315S | DS320S | ||||||
Power (kVA) | 10 | 15 | 20 | ||||||
INPUT | |||||||||
Voltage | 380/400 VAC 3P + N + G ± 20% (415VAC +15%, -25% optional ) | ||||||||
Frequency | 50Hz. / 60Hz. selectable, ± 5% | ||||||||
Power factor | > 0.99 | ||||||||
Harmonic current distortion (THDI) | < 5% | ||||||||
By-pass voltage | 380/400 VAC 3 Phase + N , 4 Wires, ± 10% | ||||||||
Voltage distortion | < 10% | ||||||||
Protection | Fuses, Voltage & Frequency Tolerance | ||||||||
OUTPUT | |||||||||
Power (kW) | 9 | 13,5 | 18 | ||||||
Power factor | 0,9 | ||||||||
Voltage | 380/400 VAC 3P + N , ± 1% (415 VAC optional ) | ||||||||
Frequency | 50Hz. / 60Hz. selectable | ||||||||
Frequency tolerance | Line synchronized: ± 2% / Free running: ± 0,1% (adjustable) | ||||||||
Efficiency | up to 94% | ||||||||
Crest factor | 3:1 | ||||||||
Overload protection | 100% – 125% load: 10 min, 125% – 150% load: 1 min, – > 150% load: by pass | ||||||||
Protection | Fuses,Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting | ||||||||
THD (at 100% linear load) | < 3% | ||||||||
BATTERIES | |||||||||
Type | VRLA AGM / GEL / NiCd | ||||||||
Number of batteries | 60 (± 30) batteries | ||||||||
Float charging voltage | ± 405 VDC (adjustable) | ||||||||
End of discharge voltage | ± 300 VDC (adjustable) | ||||||||
Battery cabinet | External (attached cabinet at the bottom of UPS) | ||||||||
Battery ambient temperature | 25°C | ||||||||
Battery protection | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) | ||||||||
Automatic battery test | Standard: every 72 hours (adjustable) | ||||||||
GENERAL | |||||||||
Standards | EN62040-1 , EN62040-2 | ||||||||
User interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, buzzer | ||||||||
Indicators | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time | ||||||||
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter | ||||||||
Communication | RS232 serial port, 4 standard DRY contact alarm relays | ||||||||
Inputs | EPO input | ||||||||
Genset kit | Standard (programmable) | ||||||||
Software | Standard T-Mon UPS Management Software (3 clients + 1 server management) | ||||||||
Alarm logging | Standard: with time & date 512 events | ||||||||
Protection | Power module over temperature, Over current, Temperature high alarms | ||||||||
Operating temperature | 0°C – 40°C | ||||||||
Protection degree | IP20 | ||||||||
Relative humidity | 90% max. (non condensing) | ||||||||
Altitude | < 1000m. above sea level | ||||||||
Acoustic noise | < 55 dBA | < 57 dBA | < 61 dBA | ||||||
Weight (kg) | 42 | 44 | 50 | ||||||
Dimensions (mm) HxWxD | 700x300x770 (without batt.) / 1000x300x800 (with 5ah batt.) /1170x300x800 (with 7-9ah batt.) | ||||||||
OPTIONS | |||||||||
Different input / output voltage | Please ask | ||||||||
Adaptors | SNMP, MODBUS, RS485, Remote panel | ||||||||
Software | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients | ||||||||
Parallel operation | Not Available |