Safety emergency stop push-button switch | Coded safety switch | Mechanical safety switch | Safety gate systems with solenoid interlock | Heavy duty pull wire emergency stop switch | Safety hinge switch | Configurable safety relay | Safety monitoring relay | Safety Electronic supervision relay | Safety magnetic proximity sensor | Safety gates system | Safety light curtain | Safety condition monitoring and diagnonsis system | Safety Compact PLC | Safety TCP/IP Ethernet Automation system | Safety Modular PLC | Configurable safety module | Safety Touch screen HMI Terminal | 3D safety camera system | Safety Camera-Based protection and measuring system | Safety bolt |
| JANUS M TRX ML TRX - 2,3 - beams Detection of the body through access control |
Model | ML 2B TRX | ML 3B TRX |
Safety level | Type 4 - SIL 3 - SILCL 3 - PL e – Cat. 4 |
PFHd (IEC 61508) | 4,83E-09 | 4,91976E-09 |
MTTFd (ISO 13849-1) years | 100 |
CCF (ISO 13849-1) | 80% |
Response time | 10 ms |
Restart | User-selectable automatic or manual |
Power supply | 24Vdc ± 20% |
Connections | 19 - poles M23 connector |
Protection rating | IP 65 |
Max. Lenght electrical connections | 100 m |
Dimensions cross-section | 50 X 60 mm |
Operating temperature | -10/55 °C |
Safety outputs | 2 fail-safe PNP-500 mA at 24 Vdc with protection against short circuit, overload, reverse polarity |
Barriers status and weak signal indicator output | PNP 100 mA at 24 Vdc |
Max Muting time-out | User selectable 30 sec. or 90 min |
Max Override time-out | 15 min |
Number of beams | 2 | 3 |
Working range | 0-3,5 m |
Muting logic | One-way activated simultaneously within max. 4 sec. |
Muting sensor | 2 optoelectronic built-in pre-aligned pre-wired |
| JANUS M TRX ML TRX G - 2,3 - beams Detection of the body through access control |
Model | ML 2B TRX G | ML 3B TRX G |
Safety level | Type 4 - SIL 3 - SILCL 3 - PL e – Cat. 4 |
PFHd (IEC 61508) | 4,83E-09 | 4,92E-09 |
MTTFd (ISO 13849-1) years | 100 |
CCF (ISO 13849-1) | 80% |
Response time | 10 ms |
Restart | User-selectable automatic or manual |
Power supply | 24Vdc ± 20% |
Connections | 19 - poles M23 connector |
Protection rating | IP 65 |
Max. Lenght electrical connections | 100 m |
Dimensions cross-section | 50 X 60 mm |
Operating temperature | -10/55 °C |
Safety outputs | 2 fail-safe PNP-500 mA at 24 Vdc with protection against short circuit, overload, reverse polarity |
Barriers status and weak signal indicator output | PNP 100 mA at 24 Vdc |
Max Muting time-out | User selectable 30 sec. or 90 min |
Max Override time-out | 15 min |
Number of beams | 2 | 3 |
Working range | 0-2 m |
Muting logic | One-way activated simultaneously within max. 4 sec. |
Muting sensor | 2 optoelectronic built-in pre-aligned pre-wired |
| JANUS M TRX ML TRX V - 2,3 - beams Detection of the body through access control |
Model | ML 2B TRX V | ML 3B TRX V |
Safety level | Type 4 - SIL 3 - SILCL 3 - PL e – Cat. 4 |
PFHd (IEC 61508) | 4,83E-09 | 4,92E-09 |
MTTFd (ISO 13849-1) years | 100 |
CCF (ISO 13849-1) | 80% |
Response time | 10 ms |
Restart | User-selectable automatic or manual |
Power supply | 24Vdc ± 20% |
Connections | 19 - poles M23 connector |
Protection rating | IP 65 |
Max. Lenght electrical connections | 100 m |
Dimensions cross-section | 50 X 60 mm |
Operating temperature | -10/55 °C |
Safety outputs | 2 fail-safe PNP-500 mA at 24 Vdc with protection against short circuit, overload, reverse polarity |
Barriers status and weak signal indicator output | PNP 100 mA at 24 Vdc |
Max Muting time-out | User selectable 30 sec. or 90 min |
Max Override time-out | 15 min |
Number of beams | 2 | 3 |
Working range | 0-2 m |
Muting logic | Bi-directional with 4 sensor simultaneously within max. 4 sec. / bi-directional seq. With 4 sensor |
Muting sensor | 4 optoelectronic built-in pre-aligned pre-wired |
| JANUS M TRX MT TRX - 2,3 - beams Detection of the body through access control |
Model | MT 2B TRX | MT 3B TRX |
Safety level | Type 4 - SIL 3 - SILCL 3 - PL e – Cat. 4 |
PFHd (IEC 61508) | 4,83E-09 | 4,91976E-09 |
MTTFd (ISO 13849-1) years | 100 |
CCF (ISO 13849-1) | 80% |
Response time | 10 ms |
Restart | User-selectable automatic or manual |
Power supply | 24Vdc ± 20% |
Connections | 19 - poles M23 connector |
Protection rating | IP 65 |
Max. Lenght electrical connections | 100 m |
Dimensions cross-section | 50 X 60 mm |
Operating temperature | -10/55 °C |
Safety outputs | 2 fail-safe PNP-500 mA at 24 Vdc with protection against short circuit, overload, reverse polarity |
Barriers status and weak signal indicator output | PNP 100 mA at 24 Vdc |
Max Muting time-out | User selectable 30 sec. or 90 min |
Max Override time-out | 15 min |
Number of beams | 2 | 3 |
Working range | 0-3,5 m |
Muting logic | Bi-directional with 4 sensor simultaneously within max. 4 sec. / bi-directional seq. With 4 sensor |
Muting sensor | 4 optoelectronic built-in pre-aligned pre-wired |
| JANUS M TRX MT TRX G - 2,3, beams Detection of the body through access control |
Model | MT 2B TRX G | MT 3B TRX G |
Safety level | Type 4 - SIL 3 - SILCL 3 - PL e – Cat. 4 |
PFHd (IEC 61508) | 4,83E-09 | 4,92E-09 |
MTTFd (ISO 13849-1) years | 100 |
CCF (ISO 13849-1) | 80% |
Response time | 10 ms |
Restart | User-selectable automatic or manual |
Power supply | 24Vdc ± 20% |
Connections | 19 - poles M23 connector |
Protection rating | IP 65 |
Max. Lenght electrical connections | 100 m |
Dimensions cross-section | 50 X 60 mm |
Operating temperature | -10/55 °C |
Safety outputs | 2 fail-safe PNP-500 mA at 24 Vdc with protection against short circuit, overload, reverse polarity |
Barriers status and weak signal indicator output | PNP 100 mA at 24 Vdc |
Max Muting time-out | User selectable 30 sec. or 90 min |
Max Override time-out | 15 min |
Number of beams | 2 | 3 |
Working range | 0-2 m |
Muting logic | Bi-directional with 4 sensor simultaneously within max. 4 sec. / bi-directional seq. With 4 sensor |
Muting sensor | 4 optoelectronic built-in pre-aligned pre-wired |
| JANUS M TRX MT TRX V - 2,3, beams Detection of the body through access control |
Model | MT 2B TRX V | MT 3B TRX V |
Safety level | Type 4 - SIL 3 - SILCL 3 - PL e – Cat. 4 |
PFHd (IEC 61508) | 4,83E-09 | 4,91976E-09 |
MTTFd (ISO 13849-1) years | 100 |
CCF (ISO 13849-1) | 80% |
Response time | 10 ms |
Restart | User-selectable automatic or manual |
Power supply | 24Vdc ± 20% |
Connections | 19 - poles M23 connector |
Protection rating | IP 65 |
Max. Lenght electrical connections | 100 m |
Dimensions cross-section | 50 X 60 mm |
Operating temperature | -10/55 °C |
Safety outputs | 2 fail-safe PNP-500 mA at 24 Vdc with protection against short circuit, overload, reverse polarity |
Barriers status and weak signal indicator output | PNP 100 mA at 24 Vdc |
Max Muting time-out | User selectable 30 sec. or 90 min |
Max Override time-out | 15 min |
Number of beams | 2 | 3 |
Working range | 0-2 m |
Muting logic | Bi-directional with 4 sensor simultaneously within max. 4 sec. / bi-directional seq. With 4 sensor |
Muting sensor | 4 optoelectronic built-in pre-aligned pre-wired |
| JANUS M TRX MI TRX - 2,3,4 beams Detection of the body through access control |
Model | MI 2B TRX | MI 3B TRX | MI 4B TRX |
Safety level | Type 4 - SIL 3 - SILCL 3 - PL e – Cat. 4 |
PFHd (IEC 61508) | 4,83E-09 | 4,91976E-09 | 5,01E-09 |
MTTFd (ISO 13849-1) years | 100 |
CCF (ISO 13849-1) | 80% |
Response time | 10 ms |
Restart | User-selectable automatic or manual |
Power supply | 24Vdc ± 20% |
Connections | 19 - poles M23 connector, Muting sensors M12-5 poles |
Protection rating | IP 65 |
Max. Lenght electrical connections | 100 m |
Dimensions cross-section | 50 X 60 mm |
Operating temperature | -10/55 °C |
Safety outputs | 2 fail-safe PNP-500 mA at 24 Vdc with protection against short circuit, overload, reverse polarity |
Barriers status and weak signal indicator output | PNP 100 mA at 24 Vdc |
Max Muting time-out | User selectable 30 sec. or 90 min |
Max Override time-out | 15 min |
Number of beams | 2 | 3 | 4 |
Working range | 0-6 m |
Muting logic | 4 sens.: bi-direct. (sequent./simult. 4 sec.) / 2 sens.: one-way/bi-direc |
Muting sensor | with relay or PNP DARK-ON output |
| JANUS M TRX MI TRXL - 2,3,4 beams Detection of the body through access control |
Model | MI 2B TRXL | MI 3B TRXL | MI 4B TRXL |
Safety level | Type 4 - SIL 3 - SILCL 3 - PL e – Cat. 4 |
PFHd (IEC 61508) | 4,83E-09 | 4,91976E-09 | 5,01E-09 |
MTTFd (ISO 13849-1) years | 100 |
CCF (ISO 13849-1) | 80% |
Response time | 10 ms |
Restart | User-selectable autom |