Màn Hình Proface Gp-4201T, Model Pfxgp4201Tad,Tft Color Lcd (65,536 Colors), Display Resolution: Qvga

Liên hệ

Kcn Tân Bình - Hcmc



CTY TNHH KỸ THUẬT ĐIỆN HIỆP LỰC

GP-4201T
Model (Global Code): PFXGP4201TAD


Thumbnail



  • High LCD
  • 2 point pressing
  • Serial x1
  • Ethernet
  • USB
  • Analysis





Functional Specification
































Display TypeTFT Color LCD
Display Size3.5"
Resolution320 x 240 pixels (QVGA)
Effective Display AreaW70.56 x H52.92 mm [W2.78 x H2.08 in.]
Display Colors65,536 Colors (No blink)/16,384 Colors (Blink)
BacklightWhite LED (User nonreplaceable parts. When replacement is required, contact your local distributor.)
Brightness Control16 Levels (Adjusted with the touch panel or the software)
Backlight Service Life50,000 hrs. or more (continuous operation at 25°C [77 °F] before backlight brightness decreases to 50%)
Language FontsJapanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters) ANK: 158 (Korean fonts, Simplified Chinese and Traditional Chinese fonts are downloadable.)
Character SizesStandard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
Font SizesStandard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*1
Text 8 x 8 dots40 char. x 30 rows
8 x 16 dots40 char. x 15 rows
16 x 16 dots20 char. x 15 rows
32 x 32 dots10 char. x 7 rows
Control Memory Variable AreaSRAM 64 KB (Rechargeable Lithium battery for backup memory)
Program AreaFLASH EPROM 132 KB (Equivalent to 15,000 steps)*2
Application MemoryFLASH EPROM 16 MB (including a logic program area)
Data BackupSRAM 320 KB (Rechargeable Lithium battery for backup memory)
Clock Accuracy±65 sec/month (deviation at room temperature and power is OFF)*3
Touch Panel TypeResistive Film (analog)
Touch Panel Resolution1,024 x 1,024
Touch Panel Service Life1,000,000 times or more
Interface Serial (COM1)RS-232C/422/485 Asynchronous Transmission, Data Length: 7 or 8 bits, Parity: none, Even or Odd, Stop Bit: 1 or 2 bits, Data Transmission Speed: 2,400 bps to 115.2 kbps, 187.5 kbps(MPI), Connector: D-Sub9 (plug)
Serial (COM2)None
Ethernet (LAN)IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX Connector: Modular jack (RJ-45) x 1
USB (TYPE-A)Conforms to USB2.0 (TYPE-A) x 1, Power Supply Voltage: DC 5 V ±5 %, Output Current: 500 mA or less, Communication Distance: 5 m [16.4 ft.] or less
USB (mini-B)Conforms to USB2.0 (mini-B) x 1, Communication Distance: 5 m [16.4 ft.] or less
SD CardNone


  1. Other font sizes can be set up with the Editor software.
  2. Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.
  3. Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec/month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.


General Specification





























Rated Input VoltageDC 24 V
Input Voltage LimitsDC 19.2 to 28.8 V
Allowable Voltage Drop2 ms or less
Power Consumption9.6 W or less
In-Rush Current30 A or less
Voltage EnduranceAC 1,000 V, 20 mA for 1 min (between charging and FG terminals)
Insulation ResistanceDC 500 V, 10 MΩ or more (between charging and FG terminals)
Surrounding Air Temperature0 to 50 °C [32 to 122 °F]
Storage Temperature-20 to 60 °C [-4 to 140 °F]
Ambient Humidity10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] or less - no condensation.)
Storage Humidity10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] or less - no condensation.)
Dust0.1 mg/m³ (10-7 oz/ft³) or less (non-conductive levels)
Pollution DegreeFor use in Pollution Degree 2 environment
AtmosphereFree of corrosive gases
Air Pressure (altitude range)800 to 1,114 hPa (2,000 m [6,561ft.] above sea level or less)
Vibration ResistanceIEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration: 9.8 m/s², X, Y, Z directions for 10 cycles (approx. 100 min)
Concussion ResistanceIEC/EN61131-2 compliant 147 m/s², X, Y, Z directions for 3 times
Noise ImmunityNoise Voltage: 1,000 Vp-p, Pulse Duration: 1 µs, Rise Time: 1 ns (via noise simulator)
Electrostatic Discharge ImmunityContact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3)
GroundingFunctional grounding: Grounding resistance of 100Ω, 2mm² (AWG 14) or thicker wire, or your country''''''''''''''''''''''''''''''''s applicable standard. (Same for FG and SG terminals)
StructureIP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*4
Cooling MethodNatural air circulation
Weight Approx.0.4 kg [0.9 lb] or less (display unit only)
External DimensionsW132 x H106 x D42 mm [W5.2 x H4.17 x D1.65 in.]
Panel Cut DimensionsW118.5 x H92.5 mm [W4.67 x H3.64 in.], Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]*5


  1. The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit''''''''''''''''''''''''''''''''s level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP''''''''''''''''''''''''''''''''s front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel''''''''''''''''''''''''''''''''s plastic cover. Therefore, prior to installing the GP unit, be sure to confirm the type of conditions that will be present in the GP''''''''''''''''''''''''''''''''s operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.
  2. Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall''''''''''''''''''''''''''''''''s material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.



External Dimensions


GP4000 Series External Dimensions



Panel Cut-out


GP4000 Series Panel Cutout


External Dimensions with cables

 


Bình luận

HẾT HẠN

0983 533 151
Mã số : 7588080
Địa điểm : Hồ Chí Minh
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 29/05/2019
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!

Gợi ý cho bạn