Product specifications |
Infrared temperature range |
566: | -40 °C to 650 °C (-40 °F to 1202 °F) | 568: | -40 °C to 800 °C (-40 °F to 1472 °F) |
|
Infrared accuracy |
| < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F); > 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater |
|
Display resolution |
|
Infrared spectral response |
|
Infrared response time |
|
Thermocouple Type-K input temperature range |
| -270 °C to 1372 °C (-454 °F to 2501 °F) |
|
Thermocouple Type-K input accuracy |
-270°C to -40°C: | ± (1 °C + 0.2 °/1 °C) (-454 °F to -40 °F: ± (2 °F + 0.2 °/1 °F)) | -40°C to 1372°C: | ± 1 % or 1 °C (-40 °F to 2501 °F: ± 1 % or 2 °F), whichever is greater |
|
D:S (distance to measurement spot size) |
|
Laser sighting |
| Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm |
|
Minimum spot size |
|
Emissivity adjustment |
| By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
|
Data storage with Date/Time stamp |
566: | 20 points | 568: | 99 points |
|
PC Interface and cable |
566: | None | 568: | USB 2.0 with FlukeView® Forms software |
|
Hi/Low alarms |
| Audible and two-color visual |
|
Min/Max/Avg/Dif |
|
Display |
| Dot matrix 98 x 96 pixels with function menus |
|
Backlight |
| Two levels, normal and extra bright for darker environments |
|
Trigger lock |
|
Switchable Celsius and Fahrenheit |
|
Power |
566: | 2 AA/LR6 Batteries | 568: | 2 AA/LR6 Batteries and USB when used with a PC |
|
Battery life |
If used continuously: | laser and backlight on,12 hours; laser and backlight off, 100 hours |
|
Operating temperature |
| 0 °C to 50 °C (32 °F to 122 °F) |
|
Storage temperature |
| -20 °C to 60 °C (-40 °F to 140 °F) |
|
Bead thermocouple Type-K range |
| -40 °C to 260 °C (-40 °F to 500 °F) |
|
Bead thermocouple Type-K accuracy |
| ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F) |
|