5550 Mechanical Vibration Switches

Tham khảo

http://auto-industryvn.com/metrix-vibration-switch-5550-421-320-1106106.html

OVERVIEW

5550 and 5550G mechanical vibration switches provide basic, economical vibration protection by means of a simple and highly reliable “over center” snap action mass and spring mechanism. In the presence of sufficient vibration along the switch’s sensitive axis, the switch snaps from a stable “untripped” state to a stable “tripped” state, allowing automatic machinery shutdown or alarming when excessive vibration occurs. Once tripped, the switch must be returned to its untripped state via its local reset plunger (5550 only), or via voltage applied to its remote reset coil (standard on 5550G, optional on 5550). A single set of silver-plated SPDT relay contacts are provided as standard for connecting the switch to a machine control or annunciation circuit. An option for DPDT contacts is also available, and for extremely corrosive environments, gold-plated relay contacts may be ordered. 

SELECTION CRITERIA

The 5550 and 5550G use identical internal mechanisms, but differ in their housing styles, mounting footprints, hazardous area ratings, and externally accessible features. While the housing used with the 5550G permits its use in the more highly explosive IIC gas group, it is not available with a local reset plunger or with an externally accessible setpoint adjustment screw. The 5550G also occupies a larger mounting footprint. For these reasons, the 5550 is generally the preferred choice except in applications where the IIC gas group is present.

SETPOINT ADJUSTMENT

The switch’s trip point can be adjusted between 0 and 16 g’s (peak) in increments of approx. 1 g (1/8th turn of setpoint adjustment screw). This adjustment screw is externally accessible on the 5550. On the 5550G, the housing’s cover must be removed to access the adjustment screw

REMOTE RESET/START UP DELAY 1

A remote reset/startup delay feature is standard on the 5550G and optional on the 5550. When the switch’s reset terminals are energized, a solenoid is activated. This solenoid will reset the switch (if in its tripped state) and then hold it in this untripped state for approximately 30 seconds*, after which normal operation of the switch resumes. This feature is useful for machines that exhibit higher-than-normal vibration during startup and need to suppress tripping functions until normal operating speeds and conditions have been reached. The holding strength of this solenoid must be properly specified at time of ordering to ensure it can force the switch into an untripped position and hold it there for the duration of the startup delay, even in the presence of high vibration levels (see ordering option C).

SPECIFICATIONS 

 55505550G
Amplitude Range0 to 16 g pk NOTE: Reset coil holding strength (option C) may limit the usable amplitude range of the switch when the startup delay feature is required.
Frequency Range0 – 60 Hz (0 – 3600 rpm)
Setpoint AdjustmentLocation: Externally AccessibleLocation: Internally Accessible (cover must be removed to access)
Resolution: 1g (approximately 1/8th turn of adjustment screw where one full turn ≈ 8g)
Range: 0 – 100% of amplitude range
Wiring EntriesOne (3/4” NPT or M20 x 1.5 – see option E)Two (3/4” NPT only – see Figure 2) 
Local ResetManual plunger-style pushbutton on switch housing Not available (must use remote electrical reset)
Temperature Limit-40°C to +70°C (-40°F to +158°F) 
-53°C to +70°C (-63°F to +158°F)*N/A
Mounting4-hole rectangular in various dimensional options (see Figure 1 and ordering option E)2-hole rectangular (see Figure 2)
Remote Electrical Reset / Startup DelayOptional (see ordering option D). Applying a momentary voltage to the reset terminals will reset the switch to its untripped position. Applying a persistent voltage to the reset terminals will suppress the trip mechanism from actuating for the duration of voltage application or 30 seconds, whichever is less (a thermistor circuit limits the maximum delay time).
Reset Coil Holding Strength2g, 5g, or 10g (see ordering option C). This option dictates the highest g-levels under which remote reset / startup delay capabilities will still operate.
Enclosure Material 

Copper-free cast aluminum (standard NEMA 4 version)

• Copper-free cast aluminum with clear epoxy coating (optional NEMA 4X version)

Cast aluminum with blue epoxy coating
Environment Rating

NEMA 4 / IP66 (standard)

• NEMA 4X / IP66 (optional)

• NEMA 3 / IP64* • NEMA 3X / IP64*

NEMA 4 / IP66 
Hazardous Area RatingExplosion Proof / Flameproof (IIB + H2 ) (see ordering option A) Flameproof (IIC)
Agency CertificationsATEX / IECEx: Ex d IIB + H2 T6 GbATEX / IECEx: Ex d IIC T6 Gb
UL US/CA: Class I Div 1 Grps B,C,D Class II Div 1 Grps E,F,G 
INMETRO: Ex d IIB + H2 T6 Gb 
EAC: 1Ex d IIB + H2 T6 GbEAC: 1Ex d IIC T6 Gb
Weight1.8 kg (4.0 lbs) 2.5 kg (5.5 lbs)
ContactsType SPDT (standard) DPDT (optional)
Plating Material Silver (standard) Gold (optional)
Ratings Silver-plated Gold-plated 15A @ 125-480 Vac 1A @ 125 Vac 1/4 hp @ 250 Vac 1/8 hp @ 125 Vac 0.5A @ 125 Vdc 0.25A @ 250 Vdc

 

ORDERING INFORMATION

5550 OUTLINE & DIMENSIONS 

 

Liên hệ: Nguyễn Chí Hải

Sdt: 0398991575

Gmail: hai@ansgroup.asia

Bình luận

HẾT HẠN

0398 991 575
Mã số : 15959111
Địa điểm : Toàn quốc
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 25/05/2020
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!

Gợi ý cho bạn