Thiết Bị Đo Độ Rung St5484E

Liên hệ

Kdc D3 Miếu Nổi, P.3, Q.bình Thạnh, Tp.hcm

ST5484E Seismic Velocity 4-20 mA Transmitter

Overview

The ST5484E is a self-contained seismic velocity transmitter that incorporates a piezoelectric accelerometer, signal integrator, RMS peak detector, and a 4-20 mA signal conditioner into a single package. It can be mounted directly on a machine case or bearing housing without intervening signal conditioning equipment. The amplitude of the integrated acceleration (velocity) signal is converted to a proportional 4-20 mA signal compatible with industrial process control instrumentation such as PLCs, DCSs, and SCADA systems that can provide trending and/or alarming capabilities for a simplified vibration monitoring strategy. When the flying lead or terminal block connector options are chosen, the transmitter does not need a separate environmental housing and can directly accept conduit. To reduce installed cost, it can be used with barriers for intrinsically safe installations, or wired directly to explosion-proof conduit fittings for explosionproof installations.

Inputs
Supply Voltage (see also note under max loop resistance)

11 – 29.6 VDC (24 VDC nominal) (intrinsically safe); 11 – 30 VDC (24 VDC nominal) (explosion proof and non-incendive);

Metrix patented IPT® independent polarity diode bridge circuit allows voltage to be connected without regard to polarity

Circuit-to-Case Isolation500 Vrms
Outputs
4-20 mAProportional to velocity full scale range (4mA = 0 vibration, 20mA = full scale vibration)
Maximum 4- 20 mA loop resistance

RL = 50 x (Vs – 11) W where Vs = Supply Voltage at transmitter terminals. NOTE: For every 50 W of resistance in the 4-20 mA loop, 1 VDC above the minimum supply voltage (11 VDC) must be available at the transmitter terminals.

For example, 12 VDC at the transmitter terminals will allow a 50 Ω loop resistance; 30 VDC at the transmitter terminals will allow a 950 Ω loop resistance.

For intrinsically safe applications, the use of a passive zener barrier will incur a voltage drop of approximately 8.1 volts at the barrier, and the loop supply voltage is limited to 26 VDC. Thus, with passive barriers and a 26 VDC supply, the maximum available voltage at the transmitter will be 17.9 VDC and the corresponding maximum loop resistance will be 345 Ω.

Dynamic Signal 100 mV/g (10.2 mV / m/s2 ) acceleration, filtered to same frequency band as proportional velocity (see ordering options E & F)
Dynamic Signal Output Impedance

10 kΩ

NOTES:

1. The dynamic signal output is short-circuit protected by means of a 10 kΩ resistor, resulting in a relatively large output impedance. Many data collectors and analyzers have relatively low input impedances (100 kΩ or less) which will load this dynamic output and attenuate the signal by 10% or more. Refer to Table 1 for the dB and percentage attenuation for various load impedances.

2. Because the ST5484E is a loop-powered device with low operating power, the dynamic signal output requires a buffer amplifier for cable runs in excess of 16 feet (5 meters). Longer cable runs will also introduce distributed cable capacitance that acts as a low-pass filter, attenuating high- frequency signal content. In such situations, consult the factory for assistance selecting an appropriate low-capacitance cable

Recommended Minimum Load Impedance (Zload) for Dynamic Signal Connection500 kΩ (see also note 1 above)
Signal Processing
Frequency Response (+/- 3dB passband)2 Hz – 1500 Hz (standard) 2 Hz – 2000 Hz (optional)
Optional HighPass Filter Corner5, 10, 20, 50, 100, or 200 Hz (must be specified at time of ordering)
High-Pass RollOf12 dB / octave
Optional LowPass Filter Corner230, 250, 350, 450, 500, or 1000 Hz (must be specified at time of ordering)
Low-pass Roll-Off 12 dB / octave
Accuracy± 2.5% (within passband) ± 4% (at corner frequencies)
Maximum Full Scale5.0 in / sec (others by request)
Minimum Full Scale0.5 in / sec (others by request) 
Full Scale Range Units

• in / sec (standard)

• mm / sec (available by request)

Amplitude DetectionTrue RMS detector; full scale may be ordered with True RMS units or scaled RMS (RMS x √2) for “derived peak” measurements See ordering option AAA.
Physical 
Operating Temperature-40°C to +100°C (-40°F to +212°F)
Weight0.9 lbs (0.36 kg) 
DimensionsRefer to Figures 1 and 2 on page 8
Sensitive AxisSame as mounting stud axis
Axis OrientationAny
Enclosure Material

• 303 stainless steel (standard)

• 316 stainless steel (optional)

Enclosure Rating

MIL-Style Connector (option D=4):

• IP67 and NEMA 4X Flying Leads and Terminal Block Connectors (option D≠4):

• IP66 when used with the following conduit elbows: 8200-001-IEC, 8200-003-IEC, 8200-008- IEC,

• No Rating* when used with the following conduit elbows: 8200-001, 8200-003, 8200-005, 8200-008, 8200-101, 8200-103, 8200-108 * NOTE: IP and NEMA ratings pending;

Connector Types

• Flying Leads (2- and 4-wire)

• MIL-C-5015 (2-wire only)

• Terminal Block (2- and 4-wire) 

Humidity

95%, non-condensing (flying lead and terminal block versions)

• 100% condensing (MIL-style connector

Approvals 
CE MarkYes
Hazardous Areas 

 CSA

• ATEX

• IECEx

• INMETRO

• KOSHA

• Custom Union EAC

  

 

                                                                                     

 

Liên hệ: Nguyễn Chí Hải

Sdt: 0398991575

Gmail: hai@ansgroup.asia

Bình luận

HẾT HẠN

0398 991 575
Mã số : 15958647
Địa điểm : Toàn quốc
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 24/05/2020
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!