Specifications of SWT (Fe probes) |
Models | Fe-2.5※1/2.5L | Fe-2.5LwA | Fe-0.6Pen | Methods | Magnetic inducing type | Ranges | 0~2.50mm | 0~600μm | Display resolutions | 1μm:0~999μm switching to 0.1μm:0~400μm 0.5μm:400~500μm 0.01mm:1.00~2.50mm | 1μm:0~600μm switching to 0.1μm:0~400μm 0.5μm:401~500μm | Accuracies (perpendicularly testing on flat face) | 0~100μm:±1μm or ±2% the reading value 101μm~2.50mm:±2% 0~100μm:±1μm or ±2% the reading value 101μm~600μm: ±2% the reading value | Probes | One point contact constant pressure type, V cut 2.5:φ15×47mm 2.5L:18x23x67mm | One point contact constant pressure type, Measuring part:About 20x57mm Total Length: about 550~1,540mm (flexible) | One point contact constant pressure type, V cut φ5.6x92.2mm | V type probe adaptors※2 /Non | Non | Accessories | Standard thickness, Zero plate for testing (Fe) | Standard thickness, Zero plate for testing (Fe) Carrying case | Standard thickness, Zero plate for testing (Fe) | Measuring objects | Coating, lining, thermal spray films, plating (except electrolyte nickel plating) etc. on magnetic metal substrate like iron, steel. | Coating, lining, plating on high/hard-to-reach/remote place on magnetic metal substrate like iron, steel. | Coating, lining, plating on a narrow/small place and part substrate like iron, steel. |
|
|
※1.Probes are heat-resistant (about 200℃). (Fe-2..5) ※2.V type probe adaptors (3 kinds: lessΦ5, Φ5~10, Φ10~20) can be used with Fe-2.5. |
|
Models | Fe-10 | Fe-20 | Methods | Magnetic inducing type | Ranges | 0~10mm | 0~20mm | Display resolutions | 1μm:0~999μm 0.01mm:1~10mm | 1μm:0~999μm 0.01mm:1~5mm 0.1mm:5~20mm | Accuracies (perpendicularly testing on flat face) | 0~3mm:±(5μm + 3% the read value) Over or 3.01mm:±3% the read value | Probes | One point contact constant pressure type, V cut φ18x47mm | One point contact constant pressure type, V cut φ35x55mm | Accessories | Standard thickness, Zero plate for testing (Fe) | Measuring objects | Relatively thicker objects | Thick objects |
|
|
Probe must be ordered separately. |
|
Specifications of SWT (NFe probes) |
Models | NFe-2.0※1/2.0L | Methods | Eddy current type | Ranges | 0~2.00mm | Display resolutions | 1μm:0~999μm switching to 0.1μm:0~400μm 0.5μm:400~500μm 0.01mm:1.00~2.00mm | Accuracies (perpendicularly on flat face) | 0~100μm:±1μm or ±2% the read value 101μm~2.00mm:±2% | Probes | One point contact constant pressure type, V cut 2.0:φ15×47mm 2.0L:18x22x57mm | V type probe adaptor※2/Non | Accessories | Standard thickness, Zero plate for testing (NFe) | Measuring objects | Insulated films on non-Magnetic metal substrates like aluminum, cupper | Relatively general use objects |
|
|
Probe must be ordered separately. ※1.Probes are heat-resistant (about 200℃). (NFe-2.0) ※2.V type probe adaptors (3 kinds:lessΦ5, Φ5~10, Φ10~20) can be used with NFe-2.0. |
|
Models | NFe-0.6 | NFe-5 | NFe-8 | Methods | Eddy current type | Ranges | 0~600μm | 0~5mm | 0~8mm | Display resolutions | 1μm:0~600μm switching to 0.1μm:0~400μm 0.5μm:400~500μm | 1μm:0~999μm 0.01mm: 1~5mm | 1μm:0~999μm 0.01mm:1~8mm | Accuracies (perpendicularly on flat face) | 0~100μm:±1μm or ±2% the read value 101μm~600μm:±2% | 0~3mm:±(5μm + ±3% the read value) Over or 3.01mm:±3% the read value | 0~3mm:±(5μm + ±3% the read value) Over or 3.01mm:±3% the read value | Probes | One point contact constant pressure type, φ13×45.5mm | One point contact constant pressure type, V cut φ20.4×47.1mm | One point contact constant pressure type, V cut φ35×59mm | Non | Accessories | Standard thickness, Zero plate for testing (NFe) | Measuring objects | Insulated films on non-Magnetic metal substrates like aluminum, cupper | like aluminum, cupper for high stability for narrow bar , tube, minute pieces | Relatively thick objects | Relatively thick objects |
|