Liên hệ
103 Thông Tây Hội, P.10, Q. Gò Vấp
Công ty TNHH TM XNK HLF
Mr. Hòa
Tel : 0973 940 975
Email : hoadinh@hlfico.com
Economically priced Alpha Systems dew point hygrometer designed for continuous analysis of air or gas or the regeneration of desiccant dryers. | |
Features:
| |
Dew Point Dewsmart Sensor The model DS1200-AMT system can be factory configured to read out in °C dewpoint, °F dewpoint, ppm(v), ppb(v), g/m³ or lbs/ MMSCF. The measured value is displayed on a large 4 digit, fourteen segment LED display. The instrument offers two fully programmable alarm relays, which can be independently set across the full operating range of the sensor. An optically isolated 4-20 ma signal, linear with the measurement units, is also provided. The model DS1200-AMT can be supplied with one of three different sensor ranges.
The “ AUTOCAL” feature provideds for easy field verification of the system response, without the need for additional equipment. |
Installation using sensor holder |
Sensor Dimensions |
Specification of DS1200 Dewpoint Hygrometer |
Model | DS1200 |
Panel meter/system | |
Ranges | HD -65°C to +20 °C dewpoint. (-85°F to +68 °F) |
Display | 4 digit 14 segment bright red LED 0.5" |
Resolution | 0.1 degsC, 0.1 degs F dewpoint or 0.1ppm (v) |
Alarm relays | 2 sets of voltage free changeover alarm contacts rated at 7A@240 VAC, 7A@30VDC Set points adjusted from the front panel |
Analog Output | Isolated 4 - 20 mA, max load 800 Ohms |
Power Supply | 24 - 250 VAC 3.5W, 50/60Hz universal power adaptor. Or |
Panel Meter Housing | 1/8 Din IP66 front panel. Cutout dimensions 92 x 45 mm |
Sensor | |
Sensor type | Aluminum Oxide Ultra High Capacitance patented Alpha Systems Dewsmart. |
Sensor Accuracy | +/- 2 degs C dewpoint |
Repeatability | better than +/- 3°C dewpoint |
Pressure | From 0.15 PSIA (0.01 barA) to Maximum 5,075 PSIA ( 350 barA) |
Sample Flow | Flow independent, ideally 4 to 10 SCFH (2 to 5 LPM). Max: 50 SCFH. |
Case material | Stainless steel IP 65 weatherproof |
Connector | 8 pin |
Cable | 4 wire shielded up to 100 m length |
Sensor Holder | |
Material | Stainless Steel |
Connections | 1/4 inch Swagelock tube fittings |
Mountings | 2 x M5 tapped holes in base or 4 holes 5 mm diameter @ 42 x 35 centers in mounting bracket |
System | |
Warm up time | 10 seconds |
Operating conditions | -20 to +60 °C (-4°F to 140°F) 10 - 90 % RH non condensing |
Storage temperature | -20 to +70°C (-4°F to 158°F) |
Electromagnetic | Emission & Immunity: Complies with EN 61326 LVD 73/23/EEC: Complies with EN 61010-1 |
Ordering Information | |||
DS1200 includes sensor, panel meter, and 6 ft cable, 2 alarm relays - 4-20 mA output | |||
Select Instrument Range | |||
DS1200-AMT-XXX | Range and display units | ||
HDF | -85°F to +68 °F dewpoint | ||
SDF | -148°F to +68 °F dewpoint. | ||
LDF | -184°F to +68 °F dewpoint. | ||
HDC | -65°C to +20 °C dewpoint. | ||
SDC | -100°C to +20 °C dewpoint. | ||
LDC | -120°C to +20°C dewpoint. | ||
SPX | 1 to 1000 PPMv | ||
MPX | 0.1 to 100 PPMv | ||
LPX | 0.01 to 10 PPMv | ||
PBX | 1 to 1000 PPBv | ||
LB20 | 0.1 to 20 lb/10^6 ft^3 | ||
*CO2 | For CO2 service add CO2 after range. | ||
Select Sensor Cable Length | |||
CAB-AMT-(XXX) | Description | ||
006 | Standard 6 foot cable with prewired NEMA 4 sensor connector. | ||
XXX | Custom cut length in feet (NEMA 4 sensor connector not pre-wired) | ||
Select Sample Cell Type (Optional) | |||
SH-AMT-(X)-(X) | Description | ||
0-0 | Cell with two 1/8" NPT female threaded connection. | ||
8-8 | Cell with two 1/8" tube fitings. | ||
4-4 | Cell with two 1/4" tube fittings. | ||
x | Explosion proof (NEMA 7/9) sensor enclosure with integral sample cell with 1/8" NPT threaded connections. | ||
Accessories | |||
Code added to the end of the instrument P/N | Description | ||
4X | Nema 4x enclosure, wall mount for DS1200 instrument. | ||
HPR | High pressure regulator. Stainless Steel. Max 3,000 PSIG. 1/4" FNPT connections. | ||
LPR | Low pressure regulator. Stainless Steel. Max 250 PSIG, 1/4 FNPT connections. | ||
F | Coalescing filter. Stainless Steel. Max 3,000 PSIG. 1/4" FNPT connections. | ||
NV | Needle valve. Stainless Steel. Max 3,000 PSIG 1/4" tube connections. | ||
FI | Flow Indicator. Max 100 PSIG. 1/4 FNPT connections. | ||
AMT Transmitter Only Includes 6'' Coaxial Cable and NIST Traceable Calibration Certificate. | |||
AMT Base Price | Call or Email | ||
HDF | -85°F to +68 °F dewpoint | ||
SDF | -148°F to +68 °F dewpoint. | ||
LDF | -184°F to +68 °F dewpoint. | ||
HDC | -65°C to +20 °C dewpoint. | ||
SDC | -100°C to +20 °C dewpoint. | ||
LDC | -120°C to +20°C dewpoint. | ||
SPX | 1 to 1000 PPMv | ||
MPX | 0.1 to 100 PPMv | ||
LPX | 0.01 to 10 PPMv | ||
PBX | 1 to 1000 PPBv | ||
LB20 | 0.1 to 20 lb/10^6 ft^3 | ||
*CO2 | For CO2 service add CO2 after range. |