Đồng Hồ Vạn Năng Fluke 113, Cung Cấp Thiết Bị Đo Fluke Chính Hãng

Liên hệ

63 Nguyễn Đình Chính-Phường 15 Q. Phú Nhuận-Tphcm


Công ty TNHH MTV Điện Đại Nam

Đ/c : 63 Nguyễn ĐÌnh Chính Phường 15, quận Phú Nhuận, TP.HCM – 0916.722.247

www.dungcudo.net.vn 

hàng chính hãng bảo hành 12 tháng.

LH: Thanh Tuyền 0916.722.247 để được giá tốt,


VCHECK 1,2

Range 6.000 V
 60.00 V
 600.0 V
Resolution 0.001 V
 0.01 V
 0.1 V
Accuracy DC, 45 to 500 Hz:2.0 % + 3
 500 Hz to 1 kHz: 4.0 % + 3
Diode test 3

Range 2.000 V
Resolution 0.001 V
Accuracy 2.0 % + 3
Continuity3

Range 
Resolution 
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer
3

Range 600.0 Ω
 6.000 kΩ
 60.00 kΩ
Resolution 0.1 Ω
 0.001 kΩ
 0.01 kΩ
Accuracy 0.9 % + 2
 0.9 % + 1
 0.9 % + 1
Capacitance3

Range 1000 nF
 10.00 μF
 100.0 μF
 9999 μF
Resolution 1 nF
 0.01 μF
 0.1 μF
 1 μF
Accuracy 1.9 % + 2
 1.9 % + 2
 1.9 % + 2
 100 μF - 1000 μF: 1.9 % + 2
 > 1000 μF: 5 % + 20

Notes:
1 All VChek voltage ranges are specified from 60 counts to 100 % of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
2 Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
3 After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.

 


Specifications
Maximum voltage between any terminal and earth ground
 600 V
Display
 3 3/4-digits, 6000 counts, updates 4/sec
Operating temperature
 -10 °C to 50 °C (14 °F to 122 °F)
Storage temperature
 -40 °C to 60 °C (-22 °F to 140 °F)
Temperature coefficient
 0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C)
Operating altitude
 2,000 m
Storage altitude
 10,000 m
Relative humidity

 95 % to 30 °C
 75 % to 40 °C
 45 % to 50 °C
Battery type
 9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery life
 Alkaline: 300 hours typical, without backlight
Shock
 1 Meter drop per IEC 61010-1-2001
Vibration
 Per MIL-PRF-28800 for Class 2 instrument
Size (HxWxL)
 167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in)
Weight
 13.0 oz (404 g)
Safety
 Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
EMI regulations
 Complies with FCC Part 15, Class B

 


Specifications
VCHECK
Input Impedance (Nominal) ~3 kΩ < 300 pF
VCHECK
Common Mode Rejection Ratio (1 kΩ Unbalanced) > 60 dB at dc, 50 or 60 Hz
Ω

Open Circuit Test Voltage < 2.7 V dc
Full Scale Voltage < 0.7 V dc
Diode test

Open Circuit Test Voltage < 2.7 V dc
Full Scale Voltage 2.000 V dc

Short Circuit Current < 350 μA
Diode test
Short Circuit Current < 1.0 mA

Bình luận

HẾT HẠN

0916 722 247
Mã số : 8968827
Địa điểm : Hồ Chí Minh
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 27/11/2020
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!