Bộ Chuyển Đổi- Filsa Vietnam Level Controllers For Liquid And Solid- Ans Vietnam

Liên hệ

D3, Kdc Mieu Noi, Dinh Tien Hoang St., W.3, Binh Thanh Dist., Hcmc, Vietnam


ANS Việt Nam là công ty XNK hàng đầu và là nhà cung cấp chuyên nghiệp các mặt hàng “Máy móc và các thiết bị, dụng cụ đo lường, kiểm tra công nghiệp”

                                        Hãy liên hệ với chúng tôi để có giá tốt nhất.

0902 337 066 <(@^@)> Ms Diệu

Email: dieu.ans@ansvietnam.com

Online contact:================================

Yahoo: hdieu27121989                       Skype:dthongdieu.


Chúng tôi rất mong được hợp tác thành công với quý khách !

Filsa Vietnam level controllers for liquid and solid 



ABOUT FILSA

 

Since 1957, Filsa has dedicated itself exclusively to manufacturing level controllers for solids and liquids.

 

The company''s outstanding national and international reputation guarantees high quality and prompt delivery of all its products. The goal is not just to maintain Filsa''s market position, but to strengthen and expand it.

 

PRODUCTS

 

CONTROLLERS FOR SOLIDS

 

OVERPRESSURE CONTROLLERS

 

Operation:

This device sends a signal if overpressurization occurs. Excess pressure can develop in silos that are filled using pneumatic pressure systems.

The principle behind these devices is very simple.They use a stainless steel membrane, large enough to keep dust and dirt from obstructing it, which is sensitive to air pressure. The membrane transmits the pressure to a rod that activates a microswitch, which in turn operates the alarm systems or mechanisms that keep product from entering the silo.

The operating pressure can be set as low as 250 mm wc (0.025 bar).The factory preset is 400 mm wc (0.04 bar).Other pressures are available.

 

Technical overview and installation


Principle of operationMain featuresProtection
Silo overpressurization sensor.They indicate inappropriate or hazardous pressure in filling systems that use compressed air.IP65

 


CasingTemperaturePressureControl contact
Plastic.Aluminum base-20°C a +80°CAccurate to 400 mm wc.Other precision levels are available. 15A 250V/AC single-pole changeover microswitch


Installation

 

KP These devices should be installed on the ceiling of the silo.In unusual circumstances, they can be mounted on a side wall.

 

VIBRATING CONTROLLERS

 

 

Operation: 

The probe is activated at its resonant frequency through a piezoelectric system.When the product covers the probe, it reduces its vibration which causes the relay to be switched to its other position.The probe is especially sensitive at its ends, but not at its base.

Technical overview


Principle of operationMain featuresProtectionCasing
Sonda vibrante

 


Adjustable sensitivity.Assembly:attachment to 1 1/2” G hose.

IP66.ATEX available upon request 

Aluminum

 


Probe and CouplingTemperaturePressurePower supplyControl contact
AISI 304 stainless steel. -20°C to +60°CMáx.
10 bar
Standard multivoltage 5A 250V/AC single-pole changeover relay

Installation

 

The ILV vibrating-probe controller is used to detect and manage fine and granular products with densities of 20 g/liter or higher.


It can be used regardless of the product’s composition. 

 

 

Operation: 

The probe is activated at its resonant frequency through a piezoelectric system.When the product covers the probe, it reduces its vibration which causes the relay to be switched to its other position.The probe is especially sensitive at its ends, but not at its base

 

Principle of operation


Principle of operationMain featuresProtectionCasing
Vibrating probe with extension

 

Adjustable sensitivity.Assembly:attachment to 1 1/2” G hose.

IP66.ATEX available upon request 

Aluminum

 


Probe and CouplingTemperaturePressurePower supplyControl contact
AISI 304 stainless steel. -20°C to +60°C

 

10 bar max.

 

Standard multivoltage 5A 250V/AC single-pole changeover relay

Installation

 

The ILV vibrating-probe controller is used to detect and manage fine and granular products with densities of 20 g/liter or higher.

It can be used regardless of the product’s composition.

 

 

Operation: 

The probe is activated at its resonant frequency through a piezoelectric system.When the product covers the probe, it reduces its vibration which causes the relay to be switched to its other position.The probe is especially sensitive at its ends, but not at its base.

 

Technical overview


Principle of operationMain featuresProtection

Casing

Vibrating probe with cable extension

 

Adjustable sensitivity.Assembly:attachment to 1 1/2” G hose.

IP66.ATEX available upon request 

Aluminum

 


Probe and CouplingTemperaturePressurePower supplyControl contact
AISI 304 stainless steel. -20°C to +60°C10 bar max. Standard multivoltage 5A 250V/AC single-pole changeover relay

Installation

 

The ILV vibrating-probe controller is used to detect and manage fine and granular products with densities of 20 g/liter or higher.


It can be used regardless of the product’s composition.

 

Operation: 

The probe is activated at its resonant frequency through a piezoelectric system.When the product covers the probe, it reduces its vibration which causes the relay to be switched to its other position.The probe is especially sensitive at its ends, but not at its base. .

 

Technical overview


Principle of operationMain featuresProtectionConnector

Vibrating probe

 

Adjustable sensitivity.Assembly:attachment to 1G hose.

IP66.

Din 43650

 


Fork and CouplingTemperaturePressurePower supply

Control contact

AISI 304 stainless steel. -20°C a +60°C10 bar max 24 V ac/dc1A 50V/AC 15W single-pole changeover relay

Installation

 ILV 660 This vibrating-probe controller is used to detect and manage fine and granular products with densities of 50 g/liter or higher. 

It can be used regardless of the product’s composition.

 

 

MEMBRANE CONTROLLERS

 

 

Operation: 

The controller’s membrane must be positioned so it will come in contact with the material to be detected.As the incoming material piles up inside the silo and covers the membrane, the pressure it exerts forces the membrane back, tilting a mechanism that activates a switch. This switch must be connected to the control systems in order to halt or activate the signaling and delivery mechanisms.

 

Technical overview


Principle of operationMain featuresMain features
Membrane.For management of free-flowing material.Nitrile, neoprene, viton, silicone, stainless membranes.Activated by pressure exerted by the material.Manages maximum, mid and minimum levels (Ø 214).IP53


CasingTemperaturePressureControl contact
Aluminum-20°C a +80°CActivation at 10 grams or higher, depending on the model and membrane 15A 250V/AC single-pole changeover microswitch

Installation:

 AD This should generally be positioned upright. It can, however, also be mounted horizontally to signal obstructions in conveyors or surfaces with a slope of 40° or less from vertical, and only if the material flowing through the silo or duct leaves the membrane completely exposed upon emptying.


 

Operation: 
The controller’s membrane must be positioned so it will come in contact with the material to be detected.As the incoming material piles up inside the silo and covers the membrane, the pressure it exerts forces the membrane back, tilting a mechanism that activates a switch. 
This switch must be connected to the control systems in order to halt or activate the signaling and delivery mechanisms.

 

Technical overview


Principle of operationMain featuresProtection
Membrane.For management of free-flowing material.Nitrile, neoprene, viton, silicone, stainless membranes.Activated by pressure exerted by the material.Manages maximum, mid and minimum levels (Ø 214).IP53


CasingTemperaturePressureContacto de Control
Aluminum-20°C a +80°CActivation at 10 grams or higher, depending on the model and membrane 
 
15A 250V/AC single-pole changeover microswitch

Installation

 

BD This should generally be positioned upright. It can, however, also be mounted horizontally to signal obstructions in conveyors or surfaces with a slope of 40° or less from vertical, and only if the material flowing through the silo or duct leaves the membrane completely exposed upon emptying.

 

 

Operation:

The controller’s membrane must be positioned so it will come in contact with the material to be detected.As the incoming material piles up inside the silo and covers the membrane, the pressure it exerts forces the membrane back, tilting a mechanism that activates a switch.

This switch activates and deactivates visual or acoustic signals or loading and unloading mechanisms in silos and vessels. 

 

Technical overview


Principle of operationMain featuresProtection
Membrane.For management of free-flowing material.Nitrile, neoprene, viton, silicone, stainless membranes.Activated by pressure exerted by the material.Manages maximum, mid and minimum levels (Ø 155).IP65


CasingTemperatureressureControl contact
Plastic.-20°C a +80°CActivation at 10 grams or higher, depending on the model and membrane 15A 250V/AC single-pole changeover microswitch

Installation

 

CD-2M This should generally be positioned upright. It can, however, also be mounted horizontally to signal obstructions in conveyors or surfaces with a slope of 40° or less from vertical, and only if the material flowing through the silo or duct leaves the membrane completely exposed upon emptying.

 

Operation: 

The controller’s membrane must be positioned so it will come in contact with the material to be detected.As the incoming material piles up inside the silo and covers the membrane, the pressure it exerts forces the membrane back, tilting a mechanism that activates a switch.

This switch activates and deactivates visual or acoustic signals or loading and unloading mechanisms in silos and vessels

 

Technical overview


Principle of operation

Principle of operation

Main features

Protection
Membrane.For management of free-flowing material.Nitrile, neoprene, viton, silicone, stainless membranes.Activated by pressure exerted by the material.Manages maximum, mid and minimum levels (Ø 155).IP53

 


CasingTemperaturePressure

Control contact

Plastic. Also available in aluminum-20°C a +80°CActivation at 10 grams or higher, depending on the model and membrane 
 
15A 250V/AC single-pole changeover microswitch


Installation

 PD This should generally be positioned upright. It can, however, also be mounted horizontally to signal obstructions in conveyors or surfaces with a slope of 40° or less from vertical, and only if the material flowing through the silo or duct leaves the membrane completely exposed upon emptying.

 

CAPACITIVE CONTROLLERS

 

 

Use:

The capacitive controller is used to manage levels in silos and vessels in which it is necessary to control the high, low, and mid levels of dry products in the form of powder or granular solids.
These include grains, feeds, flour, meal, plastics, cements, sand, minerals, chemicals, and also a wide range of food products.
The controllers prevent spills.They work with no moving parts inside the silo.Long lasting.Easy to install.IP 65 protection.

 

Technical overview


Principle of operationMain featuresProtectionCasing
Capacitive.Sensitivity setting can be configured on the control unit.IP65

DIN 43650 connector
Polypropylene

 


ProbeTemperaturePressurePower supplyControl contact
Stainless steel or Teflon -15°C to +80°C5 bar max. 

Standard 230V

50-60 Hz.
Other voltages available 
5 A 250V ca.

Installation

 

The ICS 2150 is normally installed by screwing it into the side wall of the silo at the height at which the product is to be detected, with the probe positioned horizontally.

In this type of controller, the regulation systems are housed in the control unit (ICU), located on the control panel or the most convenient other location.

 

Use:

The capacitive controller is used to manage levels in silos and vessels in which it is necessary to control the high, low, and mid levels of dry products in the form of powder or granular solids.
These include grains, feeds, flour, meal, plastics, cements, sand, minerals, chemicals, and also a wide range of food products.
The controllers prevent spills. They work with no moving parts inside the silo. Long lasting. Easy to install. IP 65 protection.

 

Technical overview


Principle of operationMain featuresProtectionCasing

Capacitive.Probe with extender.

Sensibilidad ajustable en el mismo detector.IP65Fiberglass-reinforced polyamide.

 


Probe

 

Temperature

 

Pressure

Power supply

Control contact
Polypropylene.-15°C a +60°CMáx.
5 bar

Standard 230V 50-60 Hz.Other voltages available 

2 A 250V ca.

 

Installation

 

ICC 2160 This is normally installed by screwing it into the wall of the silo at the height at which the product is to be detected, with the probe positioned horizontally.If the product to be managed is a powder, we recommend angling the probe 20 to 30° toward the silo’s discharge outlet to help break up the material.In choosing where to install the device, it is important to consider the angle of the feeder slope and the discharge cone, so the controllers have time to send a signal to activate the delivery or signaling mechanisms.

 

 

Use:

The capacitive controller is used to manage levels in silos and vessels in which it is necessary to control the high, low, and mid levels of dry products in the form of powder or granular solids.
These include grains, feeds, flour, meal, plastics, cements, sand, minerals, chemicals, and also a wide range of food products.The controllers prevent spills.They work with no moving parts inside the silo.Long lasting.Easy to install.IP 65 protection.

 

Technical overview


Principle of operationMain featuresProtectionCasing

Capacitive.Probe with extender.

Sensitivity can be configured on the detector itself.IP65Fiberglass-reinforced polyamide.

 


ProbeTemperaturePressurePower supplyControl contact


Polypropylene.

Stainless steel.(upon request) 

 

-15°C a +60°C5 bar max.

Standard 230V

50-60 Hz.
Other voltages available 
2 A 250V ca.


Installation

 

ICC V 2161 This is normally installed by screwing it into the ceiling of the silo, attempting to keep the probe situated at least 30 cm from the side walls.
If the silo will be filled via a pneumatic pressure system, we recommend a greater distance between the probe and the silo walls to avoid erroneous signals caused by pendular movements that air currents can cause.
THE INCOMING PRODUCT STREAM SHOULD NOT BE AIMED AT THE PROBE.

 

 

Technical overview


Power supplyMax. consumptionControl relay

Voltage to probe


230V/AC -15 + 15% Other voltages available

4 Va.

230V/AC 5 A Potential free

18 V. cc. max

 


Operating temperatureCasingSensitivity selectionTimerLED indicators
-15°C to +60°C.With Undecal socket. 80 x 80 x 35 mm.Potentiometer. Adjustable from 0 to 10 seconds 

1 power indicator LED. 1 relay position indicator LED.


Connection 

The probe should be connected to the control unit via two conductors with a minimum size of 1.5 square millimeters.The ICS 2150 probe includes a DIN 43650 connector, while the ICS 2150-1 probe has two cable terminals up to 2.5 millimeters. 
If the signal will be transmitted via a variable intensity, shielded cable is not needed.To facilitate the connection, the probes are equipped with a special circuit that allows the conductors to be connected without having to match the polarity.

 

DISPLACEMENT CONTROLLERS

 

MBP

Operation :

For management of minimum and mid levels of flour products in silos with plain surfaces.

These devices manage levels, flow, and obstructions. Adaptable for use in pipes, belt conveyors, chain conveyors, silos, etc. They prevent obstructions and send signals if they should occur. They facilitate automated control of material. Long lasting. Economical.

The probe must be positioned so it will come in contact with the material being managed. The stored material pushes the probe upward until it activates a switch. This switch must be connected to the control systems in order to halt or activate the signaling and delivery mechanisms.

 

Technical overview


Principle of operationMain featuresProtectionCasing
Pendular.
In any direction.
These devices manage flows and obstructions in pipes, conveyors...IP65Aluminum

 


TemperaturePressureControl contact
-20°C to +100°CFor managing products with densities of 0.150 kg/m3 and above.Single-pole changeover microswitch. 15A 250V/AC.


Installation

 MBP Material flow control in pressure transportation.

The control mechanism is adjusted to maximum sensibility. The nut on the control should be given pressure enough to ensure the recall of the probe to empty position, when it gets free of material.

 

MBR

Operation: 

For management of minimum and mid levels in silos with curved surfaces.

These devices manage levels, flow, and obstructions.Adaptable for use in pipes, belt conveyors, chain conveyors, silos, etc.They prevent obstructions and send signals if they should occur.They facilitate automated control of material.Long lasting. Economical.

The probe must be positioned so it will come in contact with the material being managed.The stored material pushes the probe upward until it activates a switch.This switch must be connected to the control systems in order to halt or activate the signaling and delivery mechanisms.

 

 

Technical overview


Principle of operationMain featuresProtectionCasing
Pendular.
In any direction.
These devices manage flows and obstructions in pipes, conveyors...IP65Aluminum

 


TemperaturePressureControl contact
-20°C to +100°CFor managing products with densities of 0.150 kg/m3 and above.Single-pole changeover microswitch. 15A 250V/AC.


Installation

 

Bình luận