Ngoài ra công ty Song Thành Công còn cung cấp và phân phối các dòng thiết bị công nghiệp hóa tự động khác: |
|
|
Eurotherm Vietnam |
Ordering Code: 2604/VH/121/D4/XX/XX/XX/XX/ XX/XX/Y2/ENG/XX/XX/XX/XX/XX/XX |
Advance Process Controller |
Vaisala Vietnam |
Code: DMT152B1DBB10A000A1A |
DMT152 Low Dewpoint Transmitter |
Mechanical connection: DMT152 Metal NPT 1/2" Thread |
Measurement parameters: Td/f, ppm |
Analog output Ch1 & Ch2 + RS-485 as standard: Analog Output 4...20mA |
Analog output parameter or function for Ch1: Td Range Td-80...+20C -112...+68F |
Analog output parameter or function for Ch2: Td Range Td-80...+20C -112...+68F ; Output units: Metric Units |
Pressure Setting for ppm Calculation: Pressure Not Specified No ppm Output |
Sensor Protection: Mesh Filter 18um Stainless Steel |
Cable for Analog Outputs and Power Supply (Port 1): No Cable |
Cable for RS485 Line and Power Supply (Port 2): No Cable |
Installation Accessories ONLY for ISO 1/2" Thread: No Accessories |
Special Features: Plastic Label 1180, 48+3mm, ZZ-Polyest |
Package: Cardboard Box ; User´s Guide: No Manual |
Vaisala Vietnam |
Code: HMS1102B1A1 |
Humidity and Temperature Transmitter: HMS110 |
Output signals: 4 ...20 mA |
Measured parameter for channel 1: Td (-40...+60´C) |
Measured parameter for channel 2: T (-40...+60´C) |
Humidity sensor: Humicap180R |
User guide: Multilingual Quick Guide |
Vaisala Vietnam |
Humidity and Temperature Transmitter HMT330 8V0A101BCAL110A0AANBAA1 |
Transmitter type : HMT338 for pressurized pipelines |
Probe cables: 2m |
No Additional temperature probe |
Calculations: Code RH+T, With Display |
Power supply: Standard (10...35V,24VAC) |
Signal output: Analog Output 4...20mA |
Analog output signals for Ch1: RH (0...100%RH) |
Analog output signals for Ch2: Temperature Range 0...+100C |
No Analog output signals for Ch3 |
Output units: Metric Units |
Option for module slot 1: Relay Module |
Option for module slot 2: no |
Cable bushings: Sealed Cable Gland M20x1.5 |
Transmitter installation: No Installation Kit |
Humidity sensor: General purpose HUMICAP180R |
Sensor protection: PPS Grid with Steel Netting |
Installation kit for probe: Fitting Body NPT1/2 with No Leak Srew |
User´s Guide HMT330 English |
No PC Accessories; No Calibration Contract ISO9001 Calibration |
Vaisala Vietnam |
Low Dewpoint Transmitter |
Code: DMT152A1DEC1XA33EA |
Mechanical connection: DMT152 Metal ISO 1/2" Thread |
Measurement parameters: Td/f, ppm |
Analog output Ch1 & Ch2 + RS-485 as standard: Analog Output 4...20mA |
Analog output parameter or function for Ch1: ppm 0...500ppm |
Analog output parameter or function for Ch2: Td Range Td-100...0C -148...+32F |
Output units: Metric Units |
Pressure Setting for ppm Calculation: Special Pressure Max 50 bar(a) |
Sensor Protection: Mesh Filter 18um Stainless Steel |
Cable for Analog Outputs and Power Supply (Port 1): Shielded Cable, 3.0m, 4-pin M8 Female Straight |
Cable for RS485 Line and Power Supply (Port 2): Cable 3m 4-pin M8 Female Straight |
Installation Accessories ONLY for ISO 1/2" Thread: Sampling Cell+Connectors DMT242SC2 |
Special Features: Plastic Label 1180, 48+3mm, ZZ-Polyest |
Hans-Schmidt Vietnam |
Model: TEM-I |
Textile Moisture Meter |
Hans-Schmidt Vietnam |
Model: 50210M |
Knife electrode (210) |
Hans-Schmidt Vietnam |
Model: 50213M |
Surface electrode (213) |
Hans-Schmidt Vietnam |
Model: 50299M |
Calibration electrode (299) |
Bình luận