Cisco CISCO1841 Power Description | | Frequency: 50 Hz or 60 Hz | Power Consumption: 50W Maximum | Power Source: Power Supply | | Cisco CISCO1841 Environmental Conditions | | Temperature: 32 degrees F (0.0 degrees C) to 104 degrees F (40.0 degrees C) Operating | Temperature: -4 degrees F (-20.0 degrees C) to 149 degrees F (65.0 degrees C) Non-operating | Humidity: 5% to 95% Non-condensing Non-operating | Humidity: 10% to 85% Non-condensing Operating | Thermal Dissipation: 153 BTU/h | | Cisco CISCO1841 Physical Characteristics | | Form Factor: Desktop | Form Factor: Wall-mountable | Dimensions: 1.73 Height x 13.5 Width x 10.8 Depth | Dimensions: 1.87 Height x 13.5 Width x 10.8 Depth | Weight: 6.2 lb | Weight: 6 lb | | Cisco CISCO1841 Miscellaneous | | Additional Information: Interface Card Slots: · Both slots on the Cisco 1841 router are HWIC slots and provide compatibility with WICs and multiflex trunk (VWICs) interface cards (for data only) VoIP support: · Voice-over-IP (VoIP) pass-through only Operating altitude: · 10,000 feet (3000 meters) @ 77degrees F (25degrees C) Noise level: · Normal operating temperature:
- <78degrees F/25.6degrees C : 34 dBA
- >78degrees F/25.6degrees C through <104degrees F/40degrees C: 37 dBA
- >104degrees F/40degrees C: 42 dBA
| System Requirements:
- Cisco IOS Software release: 12.3(8)T
- Cisco IOS Software release: 12.3(8)T
| Certifications & Standards:
- IEEE 802.3: 10BASE-T
- IEEE 802.3u: 100BASE-TX
- USB 1.1
Safety:
- UL60950-1
- CAN/CSA 60950-1
- AS 3260
- EN60950-1
EMI:
- EN 55022, 1998, class A
- CISPR22, 1997, class A
- CFR47, Part 15, Subpart B, 1995, class A
- EN61000-3-2 Harmonic Current Emission (only for equipment >75W but <16A)
- EN61000-3-3 Voltage Fluctuation and Flicker (only for equipment (ce)16A)
Immunity:
- CISPR24, 1997 ITE-Immunity characteristics, Limits and methods of measurement
- EN 55024,1998 ITE-Immunity characteristics, Limits and methods of measurement
- EN50082-1, 1997 Electromagnetic compatibility-Generic immunity standard, Part 1
- EN 300 386, 1997 Telecommunications network equipment EMC requirements
- The requirements are covered by the following standards:
- IEC 61000-4-2:1995 Immunity to Electrostatic Discharges
- IEC 61000-4-3:1995 Immunity to Radio Frequency Electromagnetic Fields
- IEC 61000-4-4:1995 Immunity to Electrical Fast Transients
- IEC 61000-4-5:1995 Immunity to Power Line Transients (Surges)
- IEC 61000-4-6:1996 Immunity to Radio Frequency Induced Conducted Disturbances
- IEC 61000-4-11:1995 Immunity to Voltage Dips, Voltage Variations, and Short Voltage Interruptions
Network homologation:
- USA-TIA-968-A, T1.TRQ.6-2001
- Canada-CS-03
- European Union-RTTE Directive 5/99
- Argentina-CTR 21
- Australia-AS/ACIF S002, S003, S016 , S031, 3043
- Brazil-225-540-788, CTR3, 225-100-717 Edition 3, NET 001/92 1990
- China-ITU-G.992.1, ITU-G.992.1, ITU-G.991.2, CTR3, ITU I.431 1993
- Hong Kong-HKTA 2033, HKTA 2033, HKTA 2014, HKTA 2017 Issue 3 2003, HKTA 2011 Issue 1, HKTA 2011 Issue 2, HKTA 2013 Issue 1
- India-I_DCA_18_02_Jun_99-199, S/ISN-01/02 Issue 1999 S/ISN-02 1 1998, IR/PRI-01/02 Issue 1 1998, S/INT-2W/02 MAY 2001, S/INT-2W/02 MAY 2001
- Israel-U.S. approval accepted
- Japan-Technical condition (DoC acceptance in process)
- Korea-U.S. approval accepted
- Mexico-U.S. approval accepted
- New Zealand-PTC 270/272, CTR 3, ACA 016 Revision 4 1997, PTC 200
- Singapore-IDA TS ADSL1 Issue 1, IDA TS ADSL 2, IDA TS HDSL, IDA TS ISDN 1 Issue 1 1999, IDA TS ISDN 3 Issue 1 1999, IDA TS PSTN 1 Issue 4 , IDA TS PSTN 1 Issue 4, IDA TS PSTN 1 Issue 4
- South Africa-U.S. approval accepted
- Taiwan-U.S. approval accepted
- IEEE 802.3: 10BASE-T
- IEEE 802.3u: 100BASE-TX
- USB 1.1
Safety:
- UL60950-1
- CAN/CSA 60950-1
- AS 3260
- EN60950-1
EMI:
- EN 55022, 1998, class A
- CISPR22, 1997, class A
- CFR47, Part 15, Subpart B, 1995, class A
- EN61000-3-2 Harmonic Current Emission (only for equipment >75W but <16A)
- EN61000-3-3 Voltage Fluctuation and Flicker (only for equipment (ce)16A)
Immunity:
- CISPR24, 1997 ITE-Immunity characteristics, Limits and methods of measurement
- EN 55024,1998 ITE-Immunity characteristics, Limits and methods of measurement
- EN50082-1, 1997 Electromagnetic compatibility-Generic immunity standard, Part 1
- EN 300 386, 1997 Telecommunications network equipment EMC requirements
- The requirements are covered by the following standards:
- IEC 61000-4-2:1995 Immunity to Electrostatic Discharges
- IEC 61000-4-3:1995 Immunity to Radio Frequency Electromagnetic Fields
- IEC 61000-4-4:1995 Immunity to Electrical Fast Transients
- IEC 61000-4-5:1995 Immunity to Power Line Transients (Surges)
- IEC 61000-4-6:1996 Immunity to Radio Frequency Induced Conducted Disturbances
- IEC 61000-4-11:1995 Immunity to Voltage Dips, Voltage Variations, and Short Voltage Interruptions
Network homologation:
- USA-TIA-968-A, T1.TRQ.6-2001
- Canada-CS-03
- European Union-RTTE Directive 5/99
- Argentina-CTR 21
- Australia-AS/ACIF S002, S003, S016 , S031, 3043
- Brazil-225-540-788, CTR3, 225-100-717 Edition 3, NET 001/92 1990
- China-ITU-G.992.1, ITU-G.992.1, ITU-G.991.2, CTR3, ITU I.431 1993
- Hong Kong-HKTA 2033, HKTA 2033, HKTA 2014, HKTA 2017 Issue 3 2003, HKTA 2011 Issue 1, HKTA 2011 Issue 2, HKTA 2013 Issue 1
- India-I_DCA_18_02_Jun_99-199, S/ISN-01/02 Issue 1999 S/ISN-02 1 1998, IR/PRI-01/02 Issue 1 1998, S/INT-2W/02 MAY 2001, S/INT-2W/02 MAY 2001
- Israel-U.S. approval accepted
- Japan-Technical condition (DoC acceptance in process)
- Korea-U.S. approval accepted
- Mexico-U.S. approval accepted
- New Zealand-PTC 270/272, CTR 3, ACA 016 Revision 4 1997, PTC 200
- Singapore-IDA TS ADSL1 Issue 1, IDA TS ADSL 2, IDA TS HDSL, IDA TS ISDN 1 Issue 1 1999, IDA TS ISDN 3 Issue 1 1999, IDA TS PSTN 1 Issue 4 , IDA TS PSTN 1 Issue 4, IDA TS PSTN 1 Issue 4
- South Africa-U.S. approval accepted
- Taiwan-U.S. approval accepted
| | Cisco CISCO1841 Original Manufacturer Warranty | | Standard Warranty: 1 Year Limited | | Cisco CISCO1841 General Information | | Manufacturer: Cisco Systems, Inc | Brand Name: Cisco | Product Series: 1800 | Product Name: 1841 Router | Product Type: Integrated Services Router | | Cisco CISCO1841 Interfaces/Ports | | Number of Ports: 2 | Fast Ethernet Port: Yes | Interfaces/Ports: 2 x RJ-45 10/100Base-TX LAN | Interfaces/Ports: 1 x Auxiliary Management | Interfaces/Ports: 1 x Console Management | Interfaces/Ports: 1 x USB | | Cisco CISCO1841 I/O Expansions | | Number of Expansion Slots: 3 | Expansion Slots: (2 Total) Expansion Slot | Expansion Slots: (1 Total) AIM | | Cisco CISCO1841 Management & Protocols | | Management:
- Cisco Router and Security Device Manager (SDM)
- Command-Line Interface (CLI)
- CiscoWorks
- Cisco AutoInstall
- Simple Network Management Protocol (SNMP)
- Cisco Router and Security Device Manager (SDM)
- Command-Line Interface (CLI)
- CiscoWorks
- Cisco AutoInstall
- Simple Network Management Protocol (SNMP)
| Protocols: TCP/IP | Protocols: SNMP | | Cisco CISCO1841 Memory | | Standard Memory: 128MB | Maximum Memory: 384MB | Memory Technology: DRAM | Flash Memory: 32 MB | | Cisco CISCO1841 Software | | Operating System:
- Cisco 1841 IOS IP BASE
- Cisco 1841 IOS IP BASE
| | Cisco CISCO1841 Power Description | | Input Voltage: 220V AC | Input Voltage: 110V AC | Input Voltage Range: 100V AC to 240V AC | Input Current: 1.5A |
|