Bán Router 1841 Còn Bảo Hành 6 Tháng

Liên hệ

227 Phạm Văn Đồng, Xuân Đỉnh, Từ Liêm, Hà Nội


Bán Router 1841 còn bảo hành 6 tháng

Giá bán: 15.000.000đ

Modular Router w/2xFE, 2 WAN slots, 64 FL/256 DR

 

THÔNG TIN CHI TIẾT SẢN PHẨM

 

 

 



Cisco CISCO1841 Power Description

 

Frequency: 50 Hz or 60 Hz

Power Consumption: 50W Maximum

Power Source: Power Supply

 

Cisco CISCO1841 Environmental Conditions

 

Temperature: 32 degrees F (0.0 degrees C) to 104 degrees F (40.0 degrees C) Operating

Temperature: -4 degrees F (-20.0 degrees C) to 149 degrees F (65.0 degrees C) Non-operating

Humidity: 5% to 95% Non-condensing Non-operating

Humidity: 10% to 85% Non-condensing Operating

Thermal Dissipation: 153 BTU/h

 

Cisco CISCO1841 Physical Characteristics

 

Form Factor: Desktop

Form Factor: Wall-mountable

Dimensions: 1.73 Height x 13.5 Width x 10.8 Depth

Dimensions: 1.87 Height x 13.5 Width x 10.8 Depth

Weight: 6.2 lb

Weight: 6 lb

 

Cisco CISCO1841 Miscellaneous

 

Additional Information:

Interface Card Slots:

·  Both slots on the Cisco 1841 router are HWIC slots and provide compatibility with WICs and multiflex trunk (VWICs) interface cards (for data only)

VoIP support:

·  Voice-over-IP (VoIP) pass-through only

Operating altitude:

·  10,000 feet (3000 meters) @ 77degrees F (25degrees C)

Noise level:

·  Normal operating temperature:


  • <78degrees F/25.6degrees C : 34 dBA
  • >78degrees F/25.6degrees C through <104degrees F/40degrees C: 37 dBA
  • >104degrees F/40degrees C: 42 dBA

System Requirements:


  • Cisco IOS Software release: 12.3(8)T
  • Cisco IOS Software release: 12.3(8)T

Certifications & Standards:


  • IEEE 802.3: 10BASE-T
  • IEEE 802.3u: 100BASE-TX
  • USB 1.1

Safety:


  • UL60950-1
  • CAN/CSA 60950-1
  • AS 3260
  • EN60950-1

EMI:


  • EN 55022, 1998, class A
  • CISPR22, 1997, class A
  • CFR47, Part 15, Subpart B, 1995, class A
  • EN61000-3-2 Harmonic Current Emission (only for equipment >75W but <16A)
  • EN61000-3-3 Voltage Fluctuation and Flicker (only for equipment (ce)16A)

Immunity:


  • CISPR24, 1997 ITE-Immunity characteristics, Limits and methods of measurement
  • EN 55024,1998 ITE-Immunity characteristics, Limits and methods of measurement
  • EN50082-1, 1997 Electromagnetic compatibility-Generic immunity standard, Part 1
  • EN 300 386, 1997 Telecommunications network equipment EMC requirements
  • The requirements are covered by the following standards:

    • IEC 61000-4-2:1995 Immunity to Electrostatic Discharges
    • IEC 61000-4-3:1995 Immunity to Radio Frequency Electromagnetic Fields
    • IEC 61000-4-4:1995 Immunity to Electrical Fast Transients
    • IEC 61000-4-5:1995 Immunity to Power Line Transients (Surges)
    • IEC 61000-4-6:1996 Immunity to Radio Frequency Induced Conducted Disturbances
    • IEC 61000-4-11:1995 Immunity to Voltage Dips, Voltage Variations, and Short Voltage Interruptions

Network homologation:


  • USA-TIA-968-A, T1.TRQ.6-2001
  • Canada-CS-03
  • European Union-RTTE Directive 5/99
  • Argentina-CTR 21
  • Australia-AS/ACIF S002, S003, S016 , S031, 3043
  • Brazil-225-540-788, CTR3,                         225-100-717             Edition 3, NET 001/92 1990
  • China-ITU-G.992.1, ITU-G.992.1, ITU-G.991.2, CTR3, ITU I.431 1993
  • Hong Kong-HKTA 2033, HKTA 2033, HKTA 2014, HKTA 2017 Issue 3 2003, HKTA 2011 Issue 1, HKTA 2011 Issue 2, HKTA 2013 Issue 1
  • India-I_DCA_18_02_Jun_99-199, S/ISN-01/02 Issue 1999 S/ISN-02 1 1998, IR/PRI-01/02 Issue 1 1998, S/INT-2W/02 MAY 2001, S/INT-2W/02 MAY 2001
  • Israel-U.S. approval accepted
  • Japan-Technical condition (DoC acceptance in process)
  • Korea-U.S. approval accepted
  • Mexico-U.S. approval accepted
  • New Zealand-PTC 270/272, CTR 3, ACA 016 Revision 4 1997, PTC 200
  • Singapore-IDA TS ADSL1 Issue 1, IDA TS ADSL 2, IDA TS HDSL, IDA TS ISDN 1 Issue 1 1999, IDA TS ISDN 3 Issue 1 1999, IDA TS PSTN 1 Issue 4 , IDA TS PSTN 1 Issue 4, IDA TS PSTN 1 Issue 4
  • South Africa-U.S. approval accepted
  • Taiwan-U.S. approval accepted
  • IEEE 802.3: 10BASE-T
  • IEEE 802.3u: 100BASE-TX
  • USB 1.1

Safety:


  • UL60950-1
  • CAN/CSA 60950-1
  • AS 3260
  • EN60950-1

EMI:


  • EN 55022, 1998, class A
  • CISPR22, 1997, class A
  • CFR47, Part 15, Subpart B, 1995, class A
  • EN61000-3-2 Harmonic Current Emission (only for equipment >75W but <16A)
  • EN61000-3-3 Voltage Fluctuation and Flicker (only for equipment (ce)16A)

Immunity:


  • CISPR24, 1997 ITE-Immunity characteristics, Limits and methods of measurement
  • EN 55024,1998 ITE-Immunity characteristics, Limits and methods of measurement
  • EN50082-1, 1997 Electromagnetic compatibility-Generic immunity standard, Part 1
  • EN 300 386, 1997 Telecommunications network equipment EMC requirements
  • The requirements are covered by the following standards:

    • IEC 61000-4-2:1995 Immunity to Electrostatic Discharges
    • IEC 61000-4-3:1995 Immunity to Radio Frequency Electromagnetic Fields
    • IEC 61000-4-4:1995 Immunity to Electrical Fast Transients
    • IEC 61000-4-5:1995 Immunity to Power Line Transients (Surges)
    • IEC 61000-4-6:1996 Immunity to Radio Frequency Induced Conducted Disturbances
    • IEC 61000-4-11:1995 Immunity to Voltage Dips, Voltage Variations, and Short Voltage Interruptions

Network homologation:


  • USA-TIA-968-A, T1.TRQ.6-2001
  • Canada-CS-03
  • European Union-RTTE Directive 5/99
  • Argentina-CTR 21
  • Australia-AS/ACIF S002, S003, S016 , S031, 3043
  • Brazil-225-540-788, CTR3,                         225-100-717             Edition 3, NET 001/92 1990
  • China-ITU-G.992.1, ITU-G.992.1, ITU-G.991.2, CTR3, ITU I.431 1993
  • Hong Kong-HKTA 2033, HKTA 2033, HKTA 2014, HKTA 2017 Issue 3 2003, HKTA 2011 Issue 1, HKTA 2011 Issue 2, HKTA 2013 Issue 1
  • India-I_DCA_18_02_Jun_99-199, S/ISN-01/02 Issue 1999 S/ISN-02 1 1998, IR/PRI-01/02 Issue 1 1998, S/INT-2W/02 MAY 2001, S/INT-2W/02 MAY 2001
  • Israel-U.S. approval accepted
  • Japan-Technical condition (DoC acceptance in process)
  • Korea-U.S. approval accepted
  • Mexico-U.S. approval accepted
  • New Zealand-PTC 270/272, CTR 3, ACA 016 Revision 4 1997, PTC 200
  • Singapore-IDA TS ADSL1 Issue 1, IDA TS ADSL 2, IDA TS HDSL, IDA TS ISDN 1 Issue 1 1999, IDA TS ISDN 3 Issue 1 1999, IDA TS PSTN 1 Issue 4 , IDA TS PSTN 1 Issue 4, IDA TS PSTN 1 Issue 4
  • South Africa-U.S. approval accepted
  • Taiwan-U.S. approval accepted

 

Cisco CISCO1841 Original Manufacturer Warranty

 

Standard Warranty: 1 Year Limited

 

Cisco CISCO1841 General Information

 

Manufacturer: Cisco Systems, Inc

Brand Name: Cisco

Product Series: 1800

Product Name: 1841 Router

Product Type: Integrated Services Router

 

Cisco CISCO1841 Interfaces/Ports

 

Number of Ports: 2

Fast Ethernet Port: Yes

Interfaces/Ports: 2 x RJ-45 10/100Base-TX LAN

Interfaces/Ports: 1 x Auxiliary Management

Interfaces/Ports: 1 x Console Management

Interfaces/Ports: 1 x USB

 

Cisco CISCO1841 I/O Expansions

 

Number of Expansion Slots: 3

Expansion Slots: (2 Total) Expansion Slot

Expansion Slots: (1 Total) AIM

 

Cisco CISCO1841 Management & Protocols

 

Management:


  • Cisco Router and Security Device Manager (SDM)
  • Command-Line Interface (CLI)
  • CiscoWorks
  • Cisco AutoInstall
  • Simple Network Management Protocol (SNMP)
  • Cisco Router and Security Device Manager (SDM)
  • Command-Line Interface (CLI)
  • CiscoWorks
  • Cisco AutoInstall
  • Simple Network Management Protocol (SNMP)

Protocols: TCP/IP

Protocols: SNMP

 

Cisco CISCO1841 Memory

 

Standard Memory: 128MB

Maximum Memory: 384MB

Memory Technology: DRAM

Flash Memory: 32 MB

 

Cisco CISCO1841 Software

 

Operating System:


  • Cisco 1841 IOS IP BASE
  • Cisco 1841 IOS IP BASE

 

Cisco CISCO1841 Power Description

 

Input Voltage: 220V AC

Input Voltage: 110V AC

Input Voltage Range: 100V AC to 240V AC

Input Current: 1.5A

 

--------------------------------------------------------------------------------------

Liên hệ ngay để được giá tốt nhất

Mr Mạnh:             0902 225 316      


Bình luận

HẾT HẠN

0972 139 566
Mã số : 3203367
Địa điểm : Hà Nội
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 30/06/2020
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!

Gợi ý cho bạn