Dei-370 - Dei Vietnam - Stc Vietnam

Liên hệ

110 Hoa Cuc Street, Ward 7, Phu Nhuan District, Hcmc







The expense of power consumption is usually counted by the generator according to its contracted capacity. Once the power demand is higher than the contracted capacity, two times of overload fine will be counted when within 10% of ultra power consumption, and three tims of overload fine will be counted when above 10% of ultra power consumption. 

The main purpose of demand-control is to restrict the total amount for power demand. When the total power demand is higher than the contraced capacity, to lessen the power consumption, parts of facilities could be shut down or keep them operating with low power loading so as to prevent any penalty on ultra power consumption and to decrease the expense.
Centralized ControlIntegrating all of electric analysis management and substation system into a software.
Remote Monitoring
Multi-level framework to communicate with Ethernet and RS485 Modbus-RTU.
Multi-functional 
network communication
Able to monitor various of digital power meters.
Multi-channel 
Connection
According to the quantity of power meter, users can add multi-network frame; the system will fetch the devices data by executing Multi Thread to increase the speed of data acquisition.
.Open Communication
Format

Adopting open communication format Modbus-RTU framework to communicate with down levels.

Promptly Monitor and
Control
Adopting software regularly detecting , the system can instantly monitor and control the operation status of every facility.
Historical RecordTo sum up the historical record by grouping-level, users can learn the record of each group and device , and can use instant chart to identify the statistic data of every interval, and to display the power consumption of groups and devices.
.Data AnalysisBy electric analysis for single group or facility to know the condition of power consumption.
Group Management(1)According to power meter distribution, users are able to build the groups and their associated graph.
(2)According to its own grouping and devices, the power consumption for the groups will be accumulation.
(3)Perfect elasticity, instant modification, counting and sum up.
Data Comparison

By comparing the parameter for groups or facilities, users can learn if there''s any abnormal condition on higher or lower power consumption; users can compare with different devices through their setting and learn its details from the report.

 




 





 
◎ All settings are done in the same page without turning to different pages.
 
◎ Direct screen display with LCD blue backlight, user-friendly design.
  Removable controlled panel makes monitor and control easier. 



  










Input power: ACAC24V±10%, single phase 50/60Hz.
PPIPID control logic
Unit selection: Temp ℃、Temp , Humidity %, Number
Communication Form: Modbus-RTU
Communication InterfaceRS- 485 
Wire Specification: 2C UL2464/24AWG communication isolated wire.
Removable control panel, maximum distance 30m (With addition power supply to extend the distance to 1200m maximum)
Failure, alert and protection status input
Series connection of DEI-6688N is feasible.


Lâm Hoài Diễm

[Cellphone]: 0916 635 755 

[Email]: diem@songthanhcong.com 

Head office: 110 Hoa Cuc Street, Ward 7, Phu Nhuan District, HCMC 

TI + 84 8 35074676              FI +84 8 35173889 

 


Bình luận

HẾT HẠN

0916 635 755
Mã số : 7310362
Địa điểm : Hồ Chí Minh
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 22/04/2020
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!

Gợi ý cho bạn