Techn. data HCTO1

Nominal capacitance C070.1pF
Accuracy (at 30°C)±2% RH (30...70% RH) / ±3%RH (0...90% RH)
Sensitivity0.25 pF / %RH
Working range humidity0...100% RH
Working range temperature-40...+140°C






Techn. data HC109

Nominal capacitance C0 (at 30°C)80 +/-12 pF
Nominal capacitance C76 (at 30°C)100.8 +/-15.1 pF
Dimensions LxBxH4.21 x 0.95 x 0.3 mm
Sensitivity0.27pF / %RH
Working range humidity0...100% RH
Working range temperature-40...120°C
Linearity error (0...98% RH)< ± 1.5% RH






Techn. data HC201

Nominal capacitance C76 (at 20°C)200 ± 30 pF
Sensitivity0,6 pF / % RH
Working range humidity10...95 % RH
Working range temperature-40...+110 °C
Linearity error (20...90% RH)< ± 2 % RH

 







Techn. data HC103M2

Nominal capacitance C0(at 30°C / 86°F) 160 ± 40 pF
Sensitivity0,55 pF / % RH
Working range humidity0...100% RH
Working range temperature-40...120°C (-40...248°F)
Linearity error (0...98% RH)< ± 2% RH
Response time t90at 23°C < 3 s / at -20°C < 15 s (typical)






Techn. data EE21

Measuring range0...100% RH; -40...60 °C
Outputs0...1/5/10V or 4...20mA
Accuracy±2% RH; ±0.2 °C
Supply24V AC/DC






Techn. data EE160

Measuring range10-95% RH; -15...60 °C
Analogue outputs0-10V or 4-20mA
Digital outputModbus RTU
Accuracy±2.5% RH; ±0.3 °C
Supply24V AC/DC






Techn. data EE10

Measuring range0-95% RH; -5...55 °C
Outputs0-10V or 4-20mA
Accuracy+/-2% RH; +/-0.25 °C
Supply24V AC/DC






Techn. data EE46

Working range10...100% RH
Switching point90 +/-3% RH
max. switching limitscurrent: 1A / voltage: 24V AC/DC
Supply24V AC/DC






Techn. data EE08

Measuring range0-100% RH; -40...80°C
Outputs2-wire digital output (E2) and analogue output 0-1/2,5/5/10V
Accuracy+/- 2% RH; +/- 0.2 °C
Supply4.5 - 15V or 7 - 30V DC






Techn. data EE220

Measuring range0...100% RH; -40...80°C
Outputs0...1/5/10 V or 4...20 mA
Accuracy+/-1.5% RH; +/-0.1°C
Supply24V AC/DC






Techn. data EE23

Measuring range0-100% RH; -40...120 °C
Outputs0-5V, 0-10V, 0-20mA, 4-20mA
Accuracy+/-1.3% RH; +/-0.2 °C
Supply24V AC/DC






Techn. data EE02

Measuring range10-95% RH, -5...55 °C
Accuracy+/-2% RH, +/-0.3 °C
Supply2x 1.5V AAA Alkali battery (battery life time: typ. 5 years)
Measurement tact10s






Techn. data HUMLOG 20

Measuring range10-95%RH, -20...50°C, 300...1300 hPa, 0...5000ppm
InterfaceUSB and LAN (ethernet)
Accuracy±2 %RH, ±0,3 °C, 0,5 hPa, ±(50ppm +3% of m.v.)
Supplybattery 4 x LRG AA or USB






Techn. data HUMLOG20 E

External inputVoltage, Current, Pt100, Thermocouple, digital RH/T-Sensor
InterfaceUSB and LAN (ethernet)
Supplybattery 4 x LRG AA or USB






Techn. data HUMIMAP 20

Measuring range0-100% RH; -40...180°C (-40...356°F)
OutputsRS485 / RS232
Accuracy+/-1.3% RH; +/-0,2°C
Supply90...250V AC (50/60 Hz)
Measuring channelsup to 32 rF/T






Techn. data EE245

Measuring valuesHumidity, Temperature, CO2
Transmission frequency2.4 GHz
Transmission systemIEE 802.15.4
Transmission power10mW
Radio range1000m in open field






Techn. data EE244

Measuring valuesHumidity, Temperature, CO2
Transmission frequency2.4 GHz
Transmission systemIEE 802.15.4
Transmission power10mW
Radio range1000m in open field






Techn. data EE242

Measuring valuesHumidity, Temperature, CO2
Transmission frequency2.4 GHz
Transmission systemIEE 802.15.4
Transmission power10mW
Radio range1000m in open field
OutputAnalog or digital Ethernet, Modbus






Techn. data EE33

Measuring range:0...100% RH; -40...180°C
Response time:< 15s
Outputs:0...1 / 5 / 10 V or 0 / 4...20 mA
Accuracy:+/-1.3% RH; +/-0.2°C
Supply:24V AC/DC






Techn. data EE31

Measuring range0-100% RH; -40...180 °C and derived quantities
Outputs0-5V, 0-10V, 0-20mA, 4-20mA
Serial interfaceRS232C + optional RS485
Accuracy±1.3% RH; ±0.2 °C
Supply24V AC/DC






Techn. data EE30EX

Measuring range0-100% RH; -40...180 °C and derived quantities
Outputs0-5V, 0-10V, 4-20mA
Accuracy+/-1.3% RH; +/-0.2 °C
Supply24V AC/DC
Operating range0.01...15bar (pressure tight version)






Techn. data EE23

Measuring range0-100% RH; -40...120 °C
Outputs0-5V, 0-10V, 0-20mA, 4-20mA
Accuracy+/-1.3% RH; +/-0.2 °C
Supply24V AC/DC






Techn. data EE220

Measuring range0...100% RH; -40...80°C
Outputs0...1/5/10 V or 4...20 mA
Accuracy+/-1.5% RH; +/-0.1°C
Supply24V AC/DC

 

****************************

Lâm Hoài Diễm

[Cellphone]: 0916 635 755

[Email]: diem@songthanhcong.com

Head office: 110 Hoa Cuc Street, Ward 7, Phu Nhuan District, HCMC 

TI + 84 8 35074676              FI +84 8 35173889 

WI www.stc-vietnam.com 

 


Bình luận

HẾT HẠN

0916 635 755
Mã số : 5910265
Địa điểm : Hồ Chí Minh
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 16/10/2020
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!

Gợi ý cho bạn