IFM |
Code: TN2511 Description: Temperature sensor with display (TN2531 is replaced by TN2511) |
KINETROL |
Model: 124-100W DA ACTUATOR MODEL 12 WITH LOW TEMPERATURE UNIT |
KINETROL |
Model: 074-004UV02000M (old 074-004U002000M) 07 VLS LIMIT SWITCH BOX (2xV3 SPDT SWITCHES) AND CONE MONITOR |
KINETROL |
Model: DP3C01 P3 PRINTED CIRCUIT BOARD |
Matsui |
Mold Temperature Controller MC5-G1-25H120 Heater: 4kW Operating Temp.: Supply Water + 10℃- 120℃ Flow Rate: 35L/min @ 1bar (50 Hz) Pump Capacity: 0.3 kW Water Supply : 20~ L/min Supply Pressure: 0.2~0.3 Mpa Weight: 40 kg Manifold: 2 way Dimension of Equipment: 232×563×524 <Option> Buzzer Hose Set |
Matsui |
Mold Temperature Controller MC5-G1-55H120 Heater: 6kW Operating Temp.: Supply Water + 10℃- 120℃ Flow Rate: 35L/min @ 1bar (50 Hz) Pump Capacity: 0.6 kW Water Supply : 55 L/min 1 bar 50 Hz Supply Pressure: 0.2~0.3 Mpa Weight: 50 kg Manifold: 4 way Dimension of Equipment: 232×627×564 <Option> Buzzer Hose Set |
Metrix |
Mech Switch 5550-411-041 Mechanical Vibration Switch Sensor Hazard Rating - ATEX, IECEx Flame Proof, Ex d IIB + H2, T6 Contacts - SPDT Full Scale Range - 5 g Reset Coil & Start Up Delay - None Wiring Entry/Mounting Plate - M20 X 1.5; METRIX 5097 / VS-2-EX / 366 Environmntal Rating - NEMA 4X, IP 66 |
Metrix |
Mech Switch 5550-421-040 Mechanical Vibration Switch Sensor Hazard Rating - ATEX, IECEx Flame Proof, Ex d IIB + H2, T6 Contacts - DPDT Full Scale Range - 5 g Reset Coil & Start Up Delay - None Wiring Entry/Mounting Plate - M20 X 1.5; METRIX 5097 / VS-2-EX / 366 Environmntal Rating - NEMA 4, IP 66 |
MOXA |
Model: IKS-6728A-4GTXSFP-HV-T Modular managed Ethernet switch with 8 10/100BaseT(X) ports, 4 10/100/1000BaseT(X) or 100/1000BaseSFP combo ports, and 2 slots for fast Ethernet modules, front cabling, 1 isolated power supply ( 85-264 VAC), -40 to 75°C |
MOXA |
Model: IKS-6728A-8PoE-4GTXSFP-HV-T Modular managed Ethernet switch with 8 10/100BaseT(X) PoE/PoE+ ports, 4 10/100/1000BaseT(X) or 100/1000BaseSFP combo ports, and 2 slots for fast Ethernet modules, front cabling, 1 isolated power supply ( 85-264 VAC), -40 to 75°C |
MOXA |
Model: EDS-205A Unmanaged Ethernet switch with 5 10/100BaseT(X) ports, -10?to?60°C operating?temperature |
MOXA |
Model: Mgate 5114 1-port Modbus/IEC101 to IEC104 gateway, 0 to 60°C operating temperature |
MOXA |
Model: Mgate 5109 1-port Modbus-to-DNP3 gateway, 0 to 60°C operating temperature |
MOXA |
Model: EDS-P510A-8PoE-2GTXSFP-T Managed Ethernet PoE Switch with 8 PoE+ ports, 2 combo gigabit Ethernet ports, -40 to 75°C |
MOXA |
Model: CBL-M62M9x8-100 Cable/CBL-M62M9x8-100 |
MOXA |
Model: CP-168U 8 Port UPCI Board, RS-232 |
MOXA |
Model: EDS-608 Compact managed Ethernet switch system with 2 slots for 4-port fast Ethernet interface modules, for a total of up to 8 ports, 0 to 60°C operating temperature |
MOXA |
Model: EDS-616 Compact managed Ethernet switch system with 4 slots for 4-port fast Ethernet interface modules, for a total of up to 16 ports, 0 to 60°C operating temperature |
MOXA |
Model: IMC-101-S-SC Industrial Media Converter, single mode, SC, 40 km, 0 to 60°C |
MOXA |
Model: CN2650I-8-2AC 8 ports RS-232/422/485 Terminal server with DB9 connector, Dual 100-200VAC input with adapter with 2 KV isolation |
MOXA |
Model: ICF-1150-S-SC Industrial RS-232/422/485 to Fiber Optic Converter, SC Single mode |
MOXA |
Model: ICF-1150-S-SC-T Industrial RS-232/422/485 to Fiber Optic Converter, SC Single mode, -40 to 85 ℃ |
MTS Sensor |
Ordering code : RHM0600MD531P102 Temposonics® R-Series |
MTS Sensor |
Ordering code : 201542-2 The standard ring magnet |
MTS Sensor |
Ordering code : 400633 Magnet spacer |
MTS Sensor |
Code: RH5MA1450M01R021A100 Temposonics® R-Series V Rod Note: RHM1450MR021A01 is obsoleted |
MTS Sensor |
Part : 201542-2 Magnet |
NOHKEN |
Model: PLU2200F2 Ultrasonic level meter |
SICK |
Code: 1030014 Description :ATM60-P1H13X13 Absolute encoders |
SICK |
Code: 2029225 Description: AD-ATM60-KA3PR Adaptor |
SICK |
Code: 1046135 Description: LMS511-10100 PRO 2D LiDAR sensors |
Siemens
|
Model : 7MB2335-0NH16-3AA1 ULTRAMAT 23 Gas Analyzer Made in France |
STS SENSOR | Code: ATM.1ST/N 119499 Description: Level Transmitter Housing material: Titanium Pressure type:Absolute Pressure range: 900 ... 2200 mbar Overpressure: 3xFS Process connection: G 1/2 M, bore Ø 14 mm Electrical connection: FEP cable, level Cable length [m]: 6 Output signal: 4 ... 20 mA Supply voltage: 9 ... 33 V DC Connection configuration: white:+Vin yellow:Pout Maximum process temperature: 50°C Accuracy : <=+/- 0.25% FS Compensated temperature range: -5 ... 50°C Total error band: <=+/- 0.3% FS (max.) Seals: Viton Medium: Not specified by customer Special feature 1: Single calibration certificates for each transmitter Old part number: ATM.1ST/N2.9917.2105.44.UK |
STS SENSOR | Code: ART00069 Description: FEP cable, black |
Stucke Group | Model SYMAP® ECG Engine Control + Generator Protection |
Tougu Denki
| Model : DS-7 Sensor |
Vaisala | Code: DM70 A0A0A0B1 Hand-held Dewpoint Meter No Indicator Dewpoint probe for MI70 indicator, higher Td's No Probe Accessories NO Connection Cable to a Transmitter English User´s Guide DM70 |
Vogel | Replaced by: DSA1-S03W-1M 1A (000001940404) Pressure Sensor Pressure switch 3 bar (DS-W3-4 is discontinued) |
Vogel | Model: 213-870F (000002191881) Screen filter 160µ |
Bình luận