Bộ Chuyển Đổi Tín Hiệu Drago

2 triệu

37 Đường 16, P. Bình Trưng Đông, Q.2

CTY ÂU MỸ LÀ ĐẠI LÝ ĐỘC QUYỀN HÃNG DRAGO TẠI VIỆT NAM

CHUYÊN CUNG CẤP BỘ CHUYỂN ĐỔI TÍN HIỆU 4...20mA CŨA HÃNG DRAGO.

BỘC CHIA TÍN HIỆU 4-20mA, 0-10V

THÔNG SỐ KỸ HUẬT CỦA BỘ CHUYỂN ĐỔI TÍN HIỆU DRAGO:


Technical Data




Input


 VoltageCurrent
Input signals
(terminal/switch selectable)

± 10 V, 0...10 V, 2...10 V
± 5 V, 0...5 V, 1...5 V
± 20 mA, 0...20 mA, 4...20 mA
± 10 mA, 0...10 mA, 2...10 mA
Input resistanceApprox. 1 MOhmApprox. 25 Ohm
Input capacitanceApprox. 1 nFApprox. 1 nF
OverloadVoltage limitation via 
30 V Z–Diode, max. 
continuous current 30 mA
≤ 200 mA





Output


 VoltageCurrent
Output signals
(switch selectable)

± 10 V, 0...10 V, 2...10 V
± 5 V, 0...5 V, 1...5 V
± 20 mA, 0...20 mA, 4...20 mA
± 10 mA, 0...10 mA, 2...10 mA
Load≤ 10 mA (1 kOhm at 10 V)≤ 12 V (600 Ohm at 20 mA)
Linear transmission rangeunipolar: –2 ... +110 %, bipolar: –110 ... +110 %
Ripple< 20 mVrms





General Data


Transmission error0.1 % of final value
Temperature coefficient 2)100 ppm/K of final value
Zero/Span compensation± 10 %
Cut-off frequency (-3 dB)
> 10 kHz 1),  switchable to < 30 Hz
Test voltage4 kV, 50 Hz
Input against output against power supply
Working voltage 3)
(Basic Insulation)
Up to 1000 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010–1 between all circuits.
Protection against electrical shock 3)Protective separation according to EN 61140 by reinforced insulation in accordance with EN 61010–1 up to 600 V AC/DC for overvoltage category II and pollution degree 2 between all circuits.
Ambient temperatureOperation
Transport and storage
–20 °C to +70 °C
–35 °C to +85 °C
Power supply20 ... 253 V AC/DC,AC 48 ... 62 Hz, approx. 2 VA
DC approx. 1.0 W
EMC 4)EMVG, EN 61326 -1
Construction12.5 mm housing, protection type: IP 20
WeightApprox. 100 g






  1. Factory setting, if no other information is given by ordering
  2. Average TC in specified operating temperature range
  3. As far as relevant the standards and rules mentioned above are considered by development and production of our devices. In addition relevant assembly rules are to be considered by installation of our devices in other equipments. For applications with high working voltages, take measures to prevent accidental contact and make sure that there is sufficient distance or insulation between adjacent situated devices.
  4. Minor deviations possible during interference

Bold: Factory setting for DB 6200 AG, if no other information is given by ordering





Block diagram


Db6200

LIÊN HỆ ĐỂ ĐƯỢC TƯ VẤN:

Long Tran

Mob.: +84 909 006 435+84 909 006 435 

Email.: long.tran@aumyco.com

 

AU MY technology Service Trading Company limited

 

Add.: 93/36 Treet 02, Tam Binh Ward, Thu Duc District, Ho Chi Minh city, Vietnam

Tel.: +84 83 729 4970+84 83 729 4970        Fax: +84 83729 4970

Web.: www.aumyco.com        Mail.: info@aumyco.com



Bình luận

HẾT HẠN

0909 006 435
Mã số : 11066176
Địa điểm : Hồ Chí Minh
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 08/12/2020
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!

Gợi ý cho bạn